26 Return to Table of Contents V20.1
Pressure Control
Adjustable relief setting from 150 psi to 5000 psi
Standard screw adjustment for relief setting. Hand knob available upon request.
Removable NPT orifice plug options
SAE O-ring port for access to NPT orifice and gauging
Pressure at Y is directly additive to relief setting
Applications
Relief, Back Pressure, or Sequence Valve
Provides relief function from A to B by connecting the X pilot to the A port of the logic valve. The Y port
can be connected to the B port, but a separate drain connection is preferred. This configuration uses a 1:1
ratio logic valve.
DIN 24342 COVER
FOR PRESSURE CONTROL
SIZES 16mm TO 80mm
5000 PSI
27 Return to Table of Contents V20.1
BL= Include bolts at extra
charge
Blank= Customer will supply
bolts
Custom Orifice Size &/or
Location in “mm”
Example: if desired
orifices are 0.8 mm in X &
1.0 mm in AP, then add:
-08X10AP at end of code
General Layout
Sizes 16mm to 63mm (80mm not shown)
A
B
C
Port Size
Threads in
SAE & AP
*Orifice Size
Bolts
X
AP
2.75”
1.50”
2.1”
SAE #4
1/16-27 NPT
0.7 mm
1.0 mm
5/16-18 X 1.50” (4)
3.50"
2.00"
2.1"
SAE #4
1/16-27 NPT
0.7 mm
1.0 mm
1/2-13 X 2.00” (4)
4.00"
2.00"
2.1"
SAE #4
1/16-27 NPT
0.7 mm
1.0 mm
5/8-11 X 2.00" (4)
5.00"
2.40"
2.1"
SAE #4
1/16-27 NPT
0.7 mm
1.0 mm
3/4-10 X 2.50" (4)
5.55"
2.75"
2.1"
SAE #4
1/16-27 NPT
0.7 mm
1.0 mm
3/4-10 X 3.00" (4)
7.00"
3.38"
2.1"
SAE #6
1/8-27 NPT
0.7 mm
1.0 mm
1-1/4-7 X 3.50" (4)
9.50"
3.50"
2.0"
SAE #6
1/8-27 NPT
0.7 mm
1.0 mm
1-8 X 4.00" (8)
*Orifices installed in X SAE port and AP ports only. Other orifice sizes and locations are optional.
*Exception: 25mm has X orifice installed in X port, not X SAE port. AP orifice installed in AP port.
Order Code
AMT-PRC-**-S-**-**
Poppet Relief
Cover
Standard Relief Function
Size: 25, 32, 40, 50, 63, or 80mm
Almo
Manifold
& Tool