28 Return to Table of Contents V20.1
Adjustable relief setting from 150 psi to 5000 psi
Standard screw adjustment for relief setting. Hand knob available upon request.
Standard D03 interface for loading/venting on sizes 16mm to 40mm, D05 interface on 50mm to 80mm
Removable orifice plug options
SAE O-ring ports for access to NPT orifices, gauging, or remote piloting
Pressure at Y is directly additive to relief setting
Applications
Solenoid-Loading Relief Valve
Provides relief function from A to B of
the logic valve by connecting the X pilot
to the A port of the logic valve (shown
on the left) or by connecting the Z1 port
to the A port (shown on the right).
Using a standard directional control with
flow from P to A in the de-energized
condition will unload the valve. In the
energized state, the system will build
pressure until the relief setting is
reached. The valve can be manually
vented using the external X SAE port.
The Y port can be connected the B port
of the logic valve, but a separate drain
connection is preferred.
This configuration uses a 1:1 ratio logic
valve.
DIN 24342 COVER
FOR PRESSURE CONTROL
SIZES 16mm TO 63mm
5000 PSI
29 Return to Table of Contents V20.1
BL= Include bolts at extra
charge
Blank= Customer will supply
bolts
Custom Orifice Size &/or
Location in “mm”
Example: if desired
orifices are 0.8 mm in X &
1.0 mm in AP, then add:
-08X10AP at end of code
General Layout
Sizes 16mm to 40mm Sizes 50mm & 63mm (80 size not shown)
A
B
C
Port Size
X, Z1, & Y
Interface
Threads in
X & AP
Orifice Size
Bolts
X
AP
2.75"
2.50"
2.1"
1/4” NPT
D03
1/4-20 UNC (X)
1/16-27 NPT (AP)
0.7 mm
1.0 mm
5/16-18 X 2.50" (4)
3.50"
2.25"
2.1"
SAE #4
D03
1/16-27 NPT
0.7 mm
1.0 mm
1/2-13 X 2.25" (4)
4.00"
2.00"
2.1"
SAE #4
D03
1/16-27 NPT
0.7 mm
1.0 mm
5/8-11 X 2.00" (4)
5.00"
2.40"
2.1"
SAE #4
D03
1/16-27 NPT
0.7 mm
1.0 mm
3/4-10 X 2.50" (4)
5.55"
2.75"
2.1"
SAE #6
D05
1/16-27 NPT
0.7 mm
1.0 mm
3/4-10 X 3.00" (4)
7.00"
3.38"
2.1"
SAE #6
D05
1/8-27 NPT
0.7 mm
1.0 mm
1-1/4-7 X 3.50" (4)
9.50"
3.50"
2.1"
SAE #6
D05
1/8-27 NPT
0.7 mm
1.0 mm
1-8 X 4.00" (8)
*Orifice installed in X and AP port only. Other orifice locations are optional.
Order Code
AMT-PRC-**-L-**-**
Solenoid Loading/Venting
Relief Function
Size: 16, 25, 32, 40, 50, 63, or 80mm
Poppet Relief
Cover
Almo
Manifold
& Tool