14 Return to Table of Contents V20.1
Standard D03 interface
SAE #4 O-ring ports for external
access to X & Y
Removable orifice plug options
Ships standard as plug option #1
Applications
Dump Valve or ON/OFF valve
Can be used as a dump valve
by connecting X to the B port
(side of logic valve) &
connecting Y to drain. The
diagrams to the right show the
two different plug options.
Plug option #1 will allow the
valve to dump in the de-
energized state, & Plug option
#2 will allow the valve to
dump in the energized state.
Note: If port A is connected to a working
port, then connecting X to the B port, as
shown above, does not prevent pressure at A
from overcoming the forces acting to keep
the valve closed. Flow could occur from A to
B. To prevent this, use a separate pilot
pressure for X.
DIN 24342 COVER
FOR DIRECTIONAL CONTROL
SIZES 16mm TO 40mm
5000 PSI
Plug Option #1
Plug Option #2
15 Return to Table of Contents V20.1
General Layout
B
Threads in
AP
*Orifice
Size in P
Bolts
1.50"
1/16-27 NPT
1.0 mm
5/16-18 X 1.50" (4)
2.00"
1/16-27 NPT
1.2 mm
1/2-13 X 2.00" (4)
2.00"
1/16-27 NPT
1.3 mm
5/8-11 X 2.00" (4)
2.40”
1/16-27 NPT
1.5 mm
3/4-10 X 2.50” (4)
*Only one orifice installed in P port of D03 interface. Other orifices are optional.
Order Code
AMT-PDBASH-**-**-**
Size: 16, 25, 32, 40mm
BL= Include bolts at
extra charge
Blank= Customer will
supply bolts
Poppet Cover with
Directional Control Interface.
Basic Cover Design
H style configuration
Custom Orifice Size in
“mm” if other than
Standard Size
Examples: 08 = 0.8 mm
10 = 1.0 mm
12 = 1.2 mm
Almo
Manifold
& Tool