X-FUI-40/125
Y-T60-CB-2
X-FUI-100/125
Cartridge of
return filter
Filling cap
Air-oil
heat exchanger
(option /EA)
Water-oil heat
exchanger
(option /EW)
Suction filter Return filter
Y-FPF-030/25/V1
Y-FPF-100/25/V1
Y-LMC4G1
Y-LS4P2
Y-CS-AIR-2020K/380
Y-FAC-70
–
ASH-10/G 71 Y-GA-11
ASH-25/G 80 Y-GA-21
ASH-25/G 90 Y-GA-41
ASH-50/R 100
ASH-50/R 112
ASH-50/G 100
ASH-50/G 112
ASH-100/G 132 Y-GA-122
ASH-100/E 132 Y-GA-09V31
(7) The code must be completed with the pump diplacement.
5
MAIN COMPONENTS
Model
UNEL size of
electric motor
Coupling
Bell
housing
Y-GA-61
Y-LMC1G1
Y-LMC2G1
Y-LMC6G2
Y-LMC6V3
X-FUI-25/125
X-FUI-25/125 SP-PF-030/A25 Y-FAC-70
Y-CS-AIR-2020K/380
SP-PF-100/A25
Y-FPF-102/25/V1 SP-PF-102/A25 Y-FAC-70
– Y-FAC-30 –
Y-T80-CB-2
–
Y-CS-AIR-2010K/380
Y-GB-82/** (7)
Motor Mass[Kg] - - 7,5 9 13,5 14 23 23 30 41 52 -
ASH-10/G114 PFG-114 2,1 80 (4) – – – – – – – –
ASH-10/G128 PFG-128 4,2 45 (3) – – – – – – – –
ASH-25/G114 PFG-114 2,1 – 160 (5) – – – – – – –
ASH-25/G128 PFG-128 4,2 – 90 (4) 130 (4) 180 (5) – – – – –
ASH-25/G142 PFG-142 6,3 – 60 (3) 90 (4) 120 (4) – – – – –
ASH-25/G160 PFG-160 9 – 40 (3) 60 (3) 80 (4) – – – – –
ASH-25/G174 PFG-174 11 – 30 (3) 50 (3) 65 (3) – – – – –
ASH-50/R202 PFR-202 2,4 – – – – 350 (6) – – – –
ASH-50/R203 PFR-203 5 – – – – 250 (6) 320 (6) 350 (6) – –
ASH-50/G160 PFG-160 8,5 – – – – 120 (4) 170 (5) – – –
ASH-50/G174 PFG-174 10,5 – – – – 100 (4) 130 (5) – – –
ASH-50/G187 PFG-187 13 – – – – 80 (4) 110 (4) 150 (5) – –
ASH-50/G199 PFG-199 15,2 – – – – 70 (3) 90 (4) 120 (4) – –
ASH-100/G214 PFG-214 19,5 – – – – – – – 130 (4) 180 (5)
ASH-100/G218 PFG-218 24,6 – – – – – – – 100 (4) 130 (5)
ASH-100/G221 PFG-221 29 – – – – – – – 90 (4) 120 (4)
ASH-100/E016 PFE-31016 23 – – – – – – – 120 (5) 170 (5)
ASH-100/E022 PFE-31022 30 – – – – – – – 90 (4) 125 (5)
ASH-100/E028 PFE-31028 40 – – – – – – – 70 (3) 95 (4)
5
0
4
HYDRAULIC CHARACTERISTICS
10
25
100
Maximum pressure [bar] with motor’s power:
7
,5 kW
UNEL size
132 (1)
Capacity of
reservoir
[liters]
Pump
type
Model
F
low rate
at 1450 rpm
and 7 bar
[l/min]
0,37 kW
U
NEL size
71
(
1)
0,75 kW
UNEL size
8
0 (1)
1,1 kW
UNEL size
9
0 (1)
1,5 kW
UNEL size
9
0 (1)
2,2 kW
UNEL size
1
00 (1)
3 kW
UNEL size
1
00 (1)
4
kW
UNEL size
112 (1)
5
,5 kW
UNEL size
132 (1)
(1) Electric motor is: three phases, 4 poles, V 220/380 - 50/60 Hz (other voltages available on request), closed and ventilated, construction shape V1.
(2) Electric motor is: three phases, 4 poles, V 400/660 - 50/60 Hz (other voltages available on request), closed and ventilated, construction shape V1.
(3) Pressure relief valves type BA-243/MP/75 and manometers type X-MAN-60/100.
(4) Pressure relief valves type BA-243/MP/150 and manometers type X-MAN-60/250.
(5) Pressure relief valves type BA-243/MP/250 and manometers type X-MAN-60/250.
(6) Pressure relief valves type BA-243/M/350 and manometers type X-MAN-60/400.
Note: On the SSH-10 -HPU- the return filter is not present and assembly of heat exchangers is not expected.
I
nstallation position
H
orizontal: electric motor with vertical axis.
P
orts
P
orts P = G 1/2" on subplate BA-243/MP/**
P
orts T = G 1/2" on subplate BA-243/MP/**
C
ustomized circuits
C
ustomized circuits can be easily realized by means of modular plates type BA-243/A, molar
v
alves size ISO 4401 size 06, solenoid valves and directional valves type DH*.
In particular:
• intermediate plates type BA-243/A must be assembled between the basic plate BA-243/M*
a
nd the closing element BA-243/T, mounted on the cover of the power packs;
•
modular control valves type HMP, HM, HS, HG, HC, HQ, HR, solenoid valves and direction
v
alves type DH* can be mounted on these intermediate plates according to the requested
hydraulic sketch.
Fluid Hydraulic oil as per DIN 51524...535; for other fluids contact our technical office
Recommmended viscosity 15 ÷ 100 mm
2
/s at 40°C (ISO VG 15 ÷ 100
F
luid contamination class
I
SO 19/16, achieved with in line filters at 25 μm and β25 ≥ 75 (recommended)
Fluid temperature -20°C +60°C (standard and /WG seals) -20°C +80°C (/PE seals)
On request, water-oil (option /EW) or air-oil (option /EW) heat exchangers are available, con-
n
ected as indicated on section 쪨. Air-oil exchanger are equipped with electroimpellers sup-
p
lied at 230/400 V - 50/60 Hz.
O
n power packs type ASH-10 the heat exchangers is not available.
Ambient temperature From -20°C to + 70°C
3
MAIN CHARACTERISTICS