Servoproportional 3-way cartridges
digital, with two position transducers, sizes from 25 to 80, rugged design
FS340
9
0
X
Y
T
P
A
M
ain Spool
S
leeve
Main stage position transducer
P
ilot valve
Integral electronics
U
SB connector
F
ieldbus connectors
Main connector
P
ilot valve position transducer
A
ir bleeding
A
ir suction port
LIQZO-LEB, LIQZP-LEB
L
IQZO-LES, LIQZP-LES
S
ervoproportional 3-way cartridge valves
s
pecifically designed for high speed clo-
s
ed loop controls. They are equipped
with two LVDT position transducers for
best dynamics in directional controls and
not compensated flow regulations.
T
he cartridge execution for blocks instal-
l
ation grants high flow capabilities and
m
inimized pressure drops.
T
he integral digital electronic driver
p
erforms the valve’s hydraulic regulation
a
ccording to the reference signal and
a
ssures valve-to-valve interchangeability
t
hanks to the factory presetting.
S
ervoproportional cartridges are available
i
n LEB basic execution with analog
r
eference signals and USB port for software
f
unctional parameters setting or in LES full
e
xecution which includes also optional
a
lternated P/Q controls and fieldbus
i
nterfaces for functional parameters setting,
r
eference signals and real-time diagnostics.
LIQZO: sizes from 25 to 40,
Max flow: 500 to 1050 l/min
M
ax pressure: 350 bar
L
IQZP: sizes from 50 to 80,
Max flow: 2000 to 5000 l/min
Max pressure: 420 bar
Hydraulic options, see section
A = reversal hydraulic configuration of main spool:
P-A in rest position
Electronic options, see section
I =
current reference input and monitor 4÷20 mA (omit for
standard voltage reference input and monitor ±10 V)
Only for SN
(2)
:
F = fault signal
Q = enable signal
Z = double power supply
(3)
, enable, fault and
monitor signals - 12 pin connector
Only for SP, SL:
C = current feedback for remote transducer(s)
11
LIQZO
/
/-
Seals materials
see section
5
,
6
- = NBR
PE = FPM
BT = HNBR
25 3 L4
* ** *
Series number
Spool type
regulating characteristics:
L4 = linear
Configuration: 3 = 3 way
1
MODEL CODE
Valve size, see section
3
LIQZO = 25 32 40
l/min 185 330 420
LIQZP = 50 63 80
l/min 780 1250 2100
Nominal flow (l/min) at Dp 5 bar
Servoproportional
cartridge
LIQZO = size 25 to 40,
Pmax 350 bar
LIQZP = size 50 to 80,
Pmax 420 bar
LIQZO-LES-SN-BP-323L4/A
Alternated P/Q controls - see section 3
SN = none
SP = pressure control (1 pressure tranducer)
SL = force control (1 load cell)
L =
closed-loop
two LVDT transducer
Integral digital drivers
:
EB = basic (1)
ES = full
-- -
L ES NP
SN
-
functional symbol: Standard
simplified symbol: Standard
option /A
option /A
(1) LEB available only in version SN-NP (2) F, Q, Z options are standard for SP, SL versions
(3) double power supply only for LES
10
Fieldbus interfaces
,
USB port always present:
NP = Not present
(1)
BC = CANopen EH = EtherCAT
BP = PROFIBUS DP EI = EtherNet/IP
EW= POWERLINK EP = PROFINET IRT
Table FS340-3/E
5
MAIN CHARACTERISTICS - based on mineral oil ISO VG 46 at 50 °C
Note:
Above performance data refer to valves coupled with Atos electronic drivers,
see section
7
.
(1) with step reference input 0÷100% (2) with pilot pressure = 140 bar, see datailed diagrams in section 8.2
Ports P, A, T = 350 X = 350 Y 10
Ports P, A, T = 420 X = 350 Y 10
£ 0,1
min: 40% of system pressure max 350 recommended 140 ÷ 160
± 0,1
zero point displacement < 1% at DT = 40°C
Size
Max pressure [bar]
LIQZO
LIQZP
Nominal flow of pilot valve at Dp = 70 bar
[l/min]
Leakage of pilot valve at P = 100 bar [l/min]
Piloting pressure [bar]
Piloting volume [cm
3
]
Piloting flow (1) [l/min]
Response time 0
÷ 100% step signal (2) [ms]
Hysteresis [% of the max regulation]
Repeatability [% of the max regulation]
Thermal drift
Max regulated flow [l/min]
at Dp = 5 bar
at Dp = 10 bar
Max permissible flow
185
260
500
2,16
6,5
21
25
330
470
850
7,2
20
22
32
420
590
1050
8,9
25
22
40
780
1100
2000
17,7
43
25
50
1250
1750
3100
33,8
68
30
63
2100
3000
5000
42,7
76
34
80
4
0,2
8
0,2
28
0,5
40
0,7
100
0,7
100
0,7
W
ARNING
4
FIELDBUS - only for LES
Fieldbus allows the direct communication of the proportional valve with machine control unit for digital reference signal, diagnostics and
settings of functional parameters. Analog reference signal remain available on the main connector for quick commissioning and maintenance.
F
or detailed information about fieldbus features and specification see tech table GS510.
The loss of the pilot pressure causes the undefined position of the main spool.
T
he sudden interruption of the power supply during the valve operation causes the immediate main spool opening A n T or P n A (for
o
ption /A). This could cause pressure surges in the hydraulic system or uncontrolled movements which may lead to machine damages.
WARNING
T
o avoid overheating and possible damage of the electronic driver, the valves must be never energized without
h
ydraulic supply to the pilot stage. In case of prolonged pauses of the valve operation during the machine cycle, it is always advisable
to disable the driver (option /Q or /Z). A safety fuse 2,5 A installed on 24V
DC power supply of each valve is always recommended, see
a
lso Power supply note at sections
9
LIQZO-LEB, LES and LIQZP-LEB, LES proportional cartridges are CE marked according to the applicable Directives (e.g. Immunity/Emission
E
MC Directive and Low Voltage Directive). Installation, wirings and start-up procedures must be performed according to the general prescrip-
t
ions shown in table F003 and in the installation notes supplied with relevant components. The electrical signals of the valve (e.g. monitor
signals) must not be directly used to activate safety functions or components, as prescribed by the European standards (Safety requirements of
f
luid technology systems and components-hydraulics, EN-982).
2
G
ENERAL NOTES
Dp P-A or A-T
S
* options add the closed loop control of pressure (SP) or force (SL) to the basic functions of proportional directional valves flow regulation.
A dedicated algorithm alternates pressure (force) depending on the actual hydraulic system conditions.
An additional connector is available for transducers to be interfaced to the valve’s driver (1 pressure transducer for SP or 1 load cell for SL).
M
ain 12 pin connector is the same as /Z option plus two analog signals specific for the pressure (force) control.
For detailed information and connector wiring of options SP, SL see tech table GS212.
3
A
L
T
E
R
N
A
T
E
D
P
/
Q
C
O
N
T
R
O
L
S
-
o
n
l
y
f
o
r
L
E
S
Assembly position Any position
Subplate surface finishing Roughness index, Ra 0,4 flatness ratio 0,01/100 (ISO 1101)
MTTFd values according to EN ISO 13849 75 years, see technical table P007
Ambient temperature range
standard = -20°C ÷ +60°C /BT option = -40°C ÷ +60°C
Storage temperature range
standard = -20°C ÷ +70°C /BT option = -40°C ÷ +70°C
Coil resistance R at 20°C
3 ÷ 3,3 W
Max. solenoid current 2,6 A
Max. power 50 Watt
Insulation class
H (180°) Due to the occuring surface temperatures of the solenoid coils, the European standards
ISO 13732-1 and EN982 must be taken into account
Protection degree to DIN EN60529 IP66/67 with mating connector
Tropicalization Tropical coating on electronics PCB
Duty factor Continuous rating (ED=100%)
EMC, climate and mechanical load See technical table G004
Communication interface
USB
Atos ASCII coding
CANopen
EN50325-4 + DS408
PROFIBUS DP
EN50170-2/IEC61158
EtherCAT, POWERLINK
EtherNet/IP, PROFINET IO RT/IRT
IEC 61158
Communication physical layer
not insulated
USB 2.0 + USB OTG
optical insulated
CAN ISO11898
optical insulated
RS485
Fast Ethernet, insulated
100 Base TX
N
ote: for main and communication connector see sections ,
13 14
8
DIAGRAMS (based on mineral oil ISO VG 46 at 50 °C)
8
.1 Regulation diagrams, see note
1
= LIQZO, LIQZP (all sizes)
Re
gu
l
a
te
d fl
o
w
[% o
f m
a
x
]
R
e
f
e
r
e
n
c
e
si
g
n
a
l
[
V
]
1
Hydraulic configuration vs. reference signal:
standard option /A
Reference signal 0 ÷+10 V
P n A A n T
12÷20 mA
Reference signal 0 ÷-10 V
A n T P n A
4÷12 mA
8.2 Response time
The response times in below diagrams are measured at different steps of the reference input signal. They have to be considered as average values.
For the valves with digital electronics the dynamics performances can be optimized by setting the internal software parameters.
Time [ms]
Time [ms]
Time [ms]
Spool stroke [%]
Spool stroke [%]
Spool stroke [%]
Step signal [%]
Step signal [%]
Step signal [%]
0-100
0-75
0-50
0-25
0-100
0-75
0-50
0-25
0-100
0-75
0-50
0-25
LIQZO-25
-32
-40
LIQZP-50
LIQZP-63
Time [ms]
Spool stroke [%]
Step signal [%]
0-100
0-75
0-50
0-25
LIQZP-80
6
SEALS AND HYDRAULIC FLUID - For other fluids not included in below table, consult our technical office
7
E
LECTRONIC DRIVERS
FS340
}
}
S
eals, recommended fluid temperature
NBR seals (standard) = -20°C ÷ +60°C, with HFC hydraulic fluids = -20°C ÷ +50°C
FKM seals (/PE option) = -20°C ÷ +80°C
HNBR seals (/BT option) = -40°C ÷ +60°C, with HFC hydraulic fluids = -40°C ÷ +50°C
Recommended viscosity 20÷100 mm
2
/s - max allowed range 15 ÷ 380 mm
2
/s
F
luid contamination class
I
SO 4406 class 20/18/15 NAS 1638 class 9, in line filters of 10 mm (b10 _>75 recommended)
H
ydraulic fluid
S
uitable seals type
C
lassification
R
ef. Standard
Mineral oils
NBR, FKM, HNBR HL, HLP, HLPD, HVLP, HVLPD DIN 51524
F
lame resistant without water
F
KM
H
FDU, HFDR
ISO 12922
F
lame resistant with water
N
BR, HNBR
H
FC
V
alve model
LEB LES LES-SP, SL
Drivers model E-RI-LEB-N E-RI-LES-N E-RI-LES-S
Type Digital
F
ormat
I
ntegral to valve
Data sheet GS208 GS210 GS212
Amplitude ratio [dB]
Frequency [Hz]
34
3
4
Phase [degrees]
Amplitude ratio [dB]
5
6
56
Phase [degrees]
Frequency [Hz]
8
.4 Bode diagrams
1 = LIQZO-L*-253L4: ± 90%
2 = LIQZO-L*-253L4: ± 5%
3 = LIQZO-L*-323L4: ± 90%
4 = LIQZO-L*-323L4: ± 5%
5 = LIQZO-L*-403L4: ± 90%
6 = LIQZO-L*-403L4: ± 5%
Amplitude ratio [dB]
F
requency [Hz]
1
2
12
Phase [degrees]
7 = LIQZP-L*-503L4: ± 90%
8 = LIQZP-L*-503L4: ± 5%
9 = LIQZP-L*-633L4: ± 90%
10= LIQZP-L*-633L4: ± 5%
11= LIQZP-L*-803L4: ± 90%
12= LIQZP-L*-803L4: ± 5%
7
8
78
9 10
9
10
11 12
11 12
Pre
s
s
u
re
a
t po
rt A [% o
f i
n
l
e
t pre
s
s
u
re
]
S
p
o
o
l
s
t
r
o
k
e
[
%
o
f
ma
x
]
8
.3 Pressure gain diagram
AIR BLEEDING
9
To be used only in case port A is connected to tank and
subjected to negative pressure, consult our technical office.
At the machine commissioning it is advisable to bleed the
air from piloting chambers, by loosening the 2 plugs shown
in the picture.
Operate the valve for few seconds at low pressure and then
lock the plugs.
Air bleeding
2 plugs G1/4”
Air suction port
1 plug G1/4”
CH 6
CH 6
Sizes 63 to 100Size 50
Air bleeding
2 plugs G1/4”
CH 6
Air suction port
1 plug G1/2”
CH 10
Air bleeding
2 plugs G1/4”
CH 6
Air suction port
1 plug G1/4”
CH 6
Size 16 to 40
Air suction
P
A
SP
MB
MA
SP
MB
MA
SP
MB
MA
FS340
1
0
HYDRAULIC OPTIONS
O
ption /A
The standard valve version provides the hydraulic configuration A-T of main
s
pool in absence of electric power supply to the valve.
T
he option /A provides the reversed configuration P-A of main spool in
absence of electric power supply to the valve.
T
his execution is particularly requested in vertical presses for safety reasons,
b
ecause in case of electric power breakdown the P-A configuration of the
main spool prevents the uncontrolled and dangerous downstroke of the press
r
am.
O
p
t
i
o
n
/
A
11
ELECTRONIC OPTIONS
S
tandard driver execution provides on the 7 pin main connector:
P
ower supply - 24 V
DC m
ust be appropriately stabilized or rectified and filtered; 2,5 A fuse time lag is required in series to each driver
power supply. Apply at least a 10000 mF/40 V capacitance to single phase rectifiers or a 4700 mF/40 V capacitance to
t
hree phase rectifiers
R
eference input signal - analog differential input with ±10 V
D
C
n
ominal range (pin D, E), proportional to desired valve spool position
Monitor output signal - analog output signal proportional to the actual valve’s spool position with ±10V
DC nominal range
N
ote: a minimum booting time between 400 and 800 ms has be considered from the driver energizing with the 24 V
DC p
ower supply before the valve
has been ready to operate. During this time the current to the valve coils is switched to zero.
1
1.1 Option /F
It provides a Fault output signal in place of the Monitor output signal, to indicate fault conditions of the driver (cable interruption of spool tran-
sducers or reference signal - for /I option): Fault presence corresponds to 0 V
DC, normal working corresponds to 24 VDC
11.2 Option /I
It provides 4 ÷ 20 mA current reference and monitor signals, instead of the standard 0 ÷ +10 V.
Input signal can be reconfigured via software selecting between voltage and current, within a maximum range of ±10 V or ±20 mA.
It is normally used in case of long distance between the machine control unit and the valve or where the reference signal can be affected by
electrical noise; the valve functioning is disabled in case of reference signal cable breakage.
11.3 Option /Q
To enable the driver, supply 24 V
DC on pin C referred to pin B: Enable input signal allows to enable/disable the current supply to the solenoid,
without removing the electrical power supply to the driver; it is used to maintain active the communication and the other driver functions when
the valve has to be disabled. This condition does not comply with European Norms EN13849-1 (ex EN954-1).
11.4 Option /Z
It provides, on the 12 pin main connector, the following additional features:
Enable Input Signal
To enable the driver, supply 24 V
DC on pin 3 referred to pin 2: Enable input signal allows to enable/disable the current supply to the solenoid,
without removing the electrical power supply to the driver; it is used to maintain active the communication and the other driver functions when
the valve has to be disabled. This condition does not comply with European Norms EN13849-1 (ex EN954-1).
Fault Output Signal
Fault output signal indicates fault conditions of the driver (solenoid short circuits/not connected, reference signal cable broken for 4÷20mA
input, etc.). Fault presence corresponds to 0 V
DC, normal working corresponds to 24 VDC (pin 11 referred to pin 2): Fault status is not affected
by the Enable input signal
Power supply for driver’s logics and communication - only for LES
Separate power supply (pin 9,10) allow to cut solenoid power supply (pin 1,2) while maintaining active diagnostics, USB and fieldbus communication.
A safety fuse is required in series to each driver power supply: 500 mA fast fuse.
11.5 Options /C - only for SP, SL
Option /C is available to connect pressure (force) transducers with 4 ÷ 20 mA current output signal, instead of the standard ±10 V.
Input signal can be reconfigured via software selecting between voltage and current, within a maximum range of ±10 V or ±20 mA.
11.6 Possible combined options
For SN: /FI, /IQ and /IZ
For SP, SL: /CI
EH, EW, EI, EP fieldbus execution,connector - M12 - 4 pin
PIN SIGNAL
TECHNICAL SPECIFICATION (1)
1
TX+
Transmitter
2
RX+
Receiver
3
TX-
Transmitter
4
RX-
Receiver
Housing
SHIELD
BC fieldbus execution, connector - M12 - 5 pin
PIN SIGNAL
TECHNICAL SPECIFICATION (1)
1
CAN_SHLD
Shield
2
not used
- pass-through connection (2)
3
CAN_GND
Signal zero data line
4
CAN_H
Bus line (high)
5
CAN_L
Bus line (low)
USB connector - M12 - 5 pin always present
PIN SIGNAL
TECHNICAL SPECIFICATION (1)
1
+5V_USB
Supply for external USB Flash Drive
2
ID
USB Flash Drive identification
3
GND_USB
Signal zero data line
4
D-
Data line -
5
D+
Data line +
BP fieldbus execution, connector - M12 - 5 pin
PIN SIGNAL
TECHNICAL SPECIFICATION (1)
1
+5V
Termination supply signal
2
LINE-A
Bus line (high)
3
DGND
Data line and termination signal zero
4
LINE-B
Bus line (low)
5
SHIELD
12.3 Communications connectors -
12.4 Remote pressure transducer connector - M12 - 5 pin - only for SP, SL
V
+
V
0
ENABLE referred to:
V
0 VL0 VL0 V0
Q_INPUT+
I
NPUT-
Q_MONITOR referred to:
AGND VL0 VL0 V0
A
GND
N
C
F_INPUT+
R
_ENABLE
N
C
F
_MONITOR referred to:
V
L0 V0
NC
VL+
D_IN0
NC
VL0
D_IN1
FAULT referred to:
V0 VL0 VL0 VL0
EARTH
1
2
3
4
5
6
7
8
9
10
11
PE
I
nput - power supply
Gnd - power supply
I
nput - on/off signal
I
nput - analog signal
Software selectable
Input - analog signal
Output - analog signal
Software selectable
G
nd - analog signal
I
nput - analog signal
S
oftware selectable
O
utput - on/off signal
O
utput - analog signal
Software selectable
Input - power supply
Input - analog signal
Gnd - power supply
Input - on/off signal
Output - on/off signal
PIN
T
ECHNICAL SPECIFICATIONS
N
OTES
L
EB-SN /Z LES-SN /Z
Fieldbus NP
Power supply 24 VDC Rectified and filtered: VRMS = 20 ÷ 32 VMAX (ripple max 10% VPP
P
ower supply 0 V
DC
E
nable (24 V
DC)
or disable (0 V
DC)
the valve
Flow reference input signal: ±10 VDC / ±20 mA maximum range
Defaults are
0 ÷ +10 VDC for standard and 4 ÷ 20 mA for /I option
N
egative reference input signal for Q_INPUT+ and F_INPUT+
Flow monitor output signal: ±10 V
DC / ±20 mA maximum range
D
efaults are
0 ÷ +10 VDC f
or standard and 4 ÷ 20 mA for /I option
Analog ground
D
o not connect
Pressure/Force reference input signal: ±10 VDC / ±20 mA maximum range
Defaults are ±10 VDC for standard and 4 ÷ 20 mA for /I option
Repeat enable, output repeter signal of enable input, referred to V0
D
o not connect
P
ressure/Force monitor output signal: ±10 V
DC /
±20 mA maximum range
D
efaults are ±10 V
DC f
or standard and 4 ÷ 20 mA for /I option
Do not connect
Power supply 24 VDC for driver’s logic and communication
Multiple pressure/force PID selection, referred to V0
Do not connect
Power supply 0 V
DC for driver’s logic and communication
Multiple pressure/force PID selection (not available for SF), referred to V0
Fault (0 V
DC
) or normal working (24 V
DC
)
Internally connected to the driver housing
L
ES-SP, SL
V+
V0
A
GND AGND
E
NABLE
Q_INPUT+
INPUT-
Q_MONITOR referred to:
A
GND V0
F
AULT
E
ARTH
A
B
C
D
E
F
G
I
nput - power supply
Gnd - power supply
Gnd - analog signal
Input - on/off signal
Input - analog signal
Software selectable
I
nput - analog signal
O
utput - analog signal
Software selectable
O
utput - on/off signal
T
ECHNICAL SPECIFICATIONS
N
OTES
S
tandard
/Q
/
F
P
ower supply 24 V
DC
Rectified and filtered: VRMS = 20 ÷ 32 VMAX (ripple max 10 % VPP)
Power supply 0 VDC
Analog ground
Enable (24 V
DC) or disable (0 VDC) the valve, referred to V0
F
low reference input signal: ±10 V
DC /
±20 mA maximum range
Defaults are 0 ÷ +10 V
DC for standard and 4 ÷ 20 mA for /I option
Negative reference input signal for Q_INPUT+
Flow monitor output signal: ±10 V
DC / ±20 mA maximum range
D
efaults are 0 ÷ +10 V
DC f
or standard and 4 ÷ 20 mA for /I option
Fault (0 V
DC) or normal working (24 VDC)
Internally connected to the driver housing
1
2.1 Main connector signals - 7 pin - standard, /F and /Q options
1
2
E
L
E
C
T
R
O
N
I
C
C
O
N
N
E
C
T
I
O
N
S
A
N
D
L
E
D
S
1
2.2 Main connector signals - 12 pin - /Z option and SP, SL
Note: do not disconnect VL0 before VL+ when the driver is connected to PC USB port
P
IN
Notes: (1) shield connection on connector’s housing is recommended (2): pin 2 can be fed with external +5V supply of CAN interface
PIN SIGNAL TECHNICAL SPECIFICATION Voltage Current
1 VF +24V
Power supply +24VDC Connect Connect
2 TR
Signal transducer ±10 VDC / ±20 mA maximum range, software selectable
Defaults are ±10 V
DC for standard and 4 ÷ 20 mA for /C option
Connect Connect
3 AGND
Common GND for transducer power and signals Connect /
4 NC
Not Connect / /
5 NC
Not Connect / /
B
A1
A2
A3
A4
ZM-5PF
ZM-5PF/BP
ZM-4PM/E
ZM-5PM
ZM-5PM/BP
ZM-4PM/E
BC
BP
EH, EW, EI, EP
ZH-5PM/1.5 (1)
P/Q controls
SP, SL
ZH-5PM/1.5
MODEL CODES OF MAIN CONNECTORS AND COMMUNICATION CONNECTORS - to be ordered separately
14
VALVE VERSION
CONNECTOR CODE
ZM-7P (IN) ZM-12P (IN)
ZH-7P (IN) ZH-12P (IN)
PROTECTION DEGREE
IP67
LEB
LES
LEB /Z
LES /Z
only for LES
DATA SHEET
GS208, GS210, GS212, K500
(1) only for SP or SL
A3
A4
C
O
N
N
EC
TO
R
S
1
3
ZH-12P
ZM-7P
ZM-12P
ZH-7P
ZM-5PM/BP
ZM-5PM
ZM-5PF
ZM-4PM/E
ZM-5PF/BP
12 pin (Metallic)7 pin (Metallic)
MAIN CONNECTORS
FIELDBUS CONNECTORS
SINGLE
PRESSURE/FORCE
TRANSDUCER
cable lenght 1,5m
Note: the use of metallic connectors is strongly recommended to meet EMC performance
12 pin (Plastic)
7 pin (Plastic)
L
1L2L3
A
A
A
A
A
A
A2
A
A
A
N
o
t
e
:
c
o
n
n
e
c
t
o
r
s
f
r
o
n
t
v
i
e
w
M
A
I
N
C
O
N
N
E
C
T
O
R
F
I
E
L
D
B
U
S
C
O
N
N
E
C
T
O
R
U
S
B
(
f
e
m
a
l
e
)
E
t
h
e
r
C
A
T
-
P
O
W
E
R
L
I
N
K
E
t
h
e
r
N
e
t
/
I
P
-
P
R
O
F
I
N
E
T
I
R
T
(
f
e
m
a
l
e
-
I
N
P
U
T
)
C
A
N
o
p
e
n
(
m
a
l
e
)
1
2
P
I
N
M
A
I
N
C
O
N
N
E
C
T
O
R
(
m
a
l
e
)
7
P
I
N
M
A
I
N
C
O
N
N
E
C
T
O
R
(
m
a
l
e
)
E
t
h
e
r
C
A
T
-
P
O
W
E
R
L
I
N
K
E
t
h
e
r
N
e
t
/
I
P
-
P
R
O
F
I
N
E
T
I
R
T
(
f
e
m
a
l
e
-
O
U
T
P
U
T
)
C
A
N
o
p
e
n
(
f
e
m
a
l
e
)
P
R
O
F
I
B
U
S
D
P
(
m
a
l
e
)
P
R
O
F
I
B
U
S
D
P
(
f
e
m
a
l
e
)
F
I
E
L
D
B
U
S
C
O
N
N
E
C
T
O
R
P
E
R
EMOTE PRESSURE
T
RANSDUCER
(
female)
DIAGNOSTIC
L
ED
LED FUNCTION DESCRIPTION
NP, BC, BP EH, EW, EI, EP
L1
VALVE STATUS LINK/ACT
L2
NETWORK STATUS NETWORK STATUS
L
3
S
OLENOID STATUS LINK/ACT
U
S
B
C
O
N
N
E
C
TO
R
(
al
w
ay
s
pr
es
ent
)
R
E
M
O
T
E
P
R
E
S
S
U
R
E
T
R
A
N
S
D
U
C
E
R
(
o
n
l
y
f
o
r
S
P
,
S
L
)
N
ot
us
ed
L
L
U
S
B
C
O
N
N
E
C
TO
R
(
al
w
ay
s
pr
es
ent
)
M
A
I
N
C
O
N
N
E
C
T
O
R
L
E
B
1
2.5 Connections layout
L
E
S
L
E
B
L
E
S
E-C-SB-USB/M12
USB CABLE
cable lenght 4 m
FS340
S
ize
Fastening bolts
c
lass 12.9
(
1)
Tightening
t
orque
M
ass (Kg)
1
6
F
ASTENING BOLTS and VALVE MASS
2
5
32
4
0
N
°4 M12x100
N
°4 M16x60
N
°4 M20x70
125 Nm
3
00 Nm
600 Nm
8,8
1
1,2
1
7,3
S
ize
50
Fastening bolts
c
lass 12.9 (
1)
N
°4 M20x80
Tightening
t
orque
6
00 Nm
M
ass (Kg)
2
4,6
6
3
80
N°4 M30x120
N
°8 M24x80
2100 Nm
1000 Nm
44,6
7
2,2
LI
Q
ZP
LI
Q
ZO
17
M
AIN CONNECTIONS INSTALLATION DIMENSIONS
15
PROGRAMMING TOOLS - see table GS500
(1) Fastening bolts supplied with the valve
U
SB connection
L
ES
LEB
E-C-SB-USB/M12 cable
E
-A-SB-USB/OPT isolator
Reference dimension
Main
connector
code
Valve size
25 32 40 50 63 80
B
ZM-7P 32 32 32 45 68 68
ZH-7P
Note 1 Note 1 Note 1
29 52 52
ZM-12P
Note 1 Note 1 Note 1 Note 1
35 35
ZH-12P
Note 1 Note 1 Note 1 Note 1 Note 1 Note 2
C (max) for standard valve
- 134 141 154 161 192 222
C (max) for /A option
- 114 121 134 141 172 202
D for standard valve
- 154 161 174 181 212 242
D for /A option
- 134 141 154 161 192 222
Above dimenions refer to the main connector fully screwed to driver’s connector. The space A = 15 mm to remove the connector must be considered
Note 1: the connector installation can be performed only if the valve’s driver protrudes from the edge of the relevant mounting manifold as
rapresented in above “Installation 2”
Note 2: the connector installation may be critic, depending to the cable size and bending radius
I
nstallation 1 - possible interference between manifold and main
connector
A
B
C
D
15 mm space to remove the 7 or 12 pin main connectors
Clearance between main connector to valve’s mounting surface.
See the below table to verify eventual interferences, depending
to the valve size and connector type
A =
B =
Max manifold dimension to avoid interference with the main con-
nector, see below table
C =
I
nstallation 2 - no interference
V
al
v
e'
s
functi
onal
p
ar
am
eter
s
and
confi
g
ur
ati
ons
,
can
b
e
eas
i
l
y
s
et
and
op
ti
m
i
z
ed
us
i
ng
A
t
o
s
E
-
S
W
p
r
o
g
r
a
m
m
in
g
so
f
t
w
a
r
e
c
o
n
n
e
c
t
e
d
via
U
S
B
p
o
r
t
t
o
t
h
e
d
ig
it
a
l
d
r
ive
r
.
F
o
r
fi
el
d
b
us
v
er
s
i
ons
,
the
s
oftw
ar
e
p
er
m
i
ts
v
al
v
e'
s
p
ar
am
eter
i
z
ati
on
thr
oug
h
U
S
B
p
or
t
al
s
o
i
f
the d
r
i
v
er
i
s
connected
to the centr
al
m
achi
ne uni
t v
i
a fi
el
d
b
us
.
The s
oftw
ar
e i
s
av
ai
l
ab
l
e i
n d
i
ffer
ent v
er
s
i
ons
accor
d
i
ng
to the d
r
i
v
er
s
op
ti
ons
:
E-
SW
-
B
A
SI
C
s
u
p
p
o
r
t
:
N
P
(
U
S
B)
P
S
(
S
e
r
i
a
l
)
I
R
(
I
n
f
r
a
r
e
d
)
E-
SW
-
F
I
EL
D
B
U
S
s
u
p
p
o
r
t
:
BC
(
C
AN
o
p
e
n
)
BP
(
P
RO
F
I
BU
S
D
P
)
E
H
(
E
t
h
e
r
C
AT
)
E
W
(
P
O
W
E
RL
I
N
K)
E
I
(
E
t
h
e
r
N
e
t
/
I
P
)
E
P
(
P
RO
F
I
N
E
T
I
RT
)
E
-
S
W-
*
/
P
Q
s
u
p
p
o
r
t
:
va
lve
s
w
it
h
S
P
,
S
F
,
S
L
a
lt
e
r
n
a
t
e
d
c
o
n
t
r
o
l
(
e
.
g
.
E
-
S
W
-
B
A
S
I
C
/
P
Q)
W
A
R
N
I
N
G
:
d
r
iver
s U
S
B p
o
r
t
is n
o
t
iso
lat
ed
!
The us
e of i
s
ol
ator
ad
ap
ter
i
s
hi
g
hl
y
r
ecom
m
end
ed
for
P
C p
r
otecti
on (
se
e
t
a
b
l
e
G
S5
0
0
)
1
8 INSTALLATION DIMENSIONS [mm] mounting surface and cavity, see table P006
LIQZO-LEB-253
L
IQZO-LES-253
L
IQZO-LEB-323
L
IQZO-LES-323
LIQZO-LEB-**-403
LIQZO-LES-**-403
237
Note: for mounting surface and cavity dimensions see tech. table P006
LIQZP-LEB-503
LIQZP-LES-503
110
80
92
15
8
5x85 205
237
105
30
92
100X100 205
240
120
39
92
15
125x125 205
317
129
49
105
15
140x140 205
15
140
155 for SP, SL,
E
W - POWERLINK,
EI - EtherNet/IP,
E
P - PROFINET IRT
140
Space to remove the 7 or 12 pin main connector. For main and communication connectors see section ,
13 14
FS340
1
5
5
f
o
r
S
P
,
S
L,
E
W
-
P
O
WE
R
L
I
N
K
,
EI
-
Et
h
e
rN
e
t
/
I
P,
EP -
PRO
F
I
N
ET
I
RT
140
155 for SP, SL,
EW - POWERLINK,
EI - EtherNet/IP,
EP - PROFINET IRT
140
155 for SP, SL,
EW - POWERLINK,
EI - EtherNet/IP,
EP - PROFINET IRT
LIQZP-LEB-803
L
IQZP-LES-803
LIQZP-LEB-633
L
IQZP-LES-633
01/18
Note: for mounting surface and cavity dimensions see see tech. table P006
336
142
76
15
128
45
162
356
15
128
1
80x180 405
Ø250 405
Space to remove the 7 or 12 pin main connector. For main and communication connectors see section ,
13 14
150
165 for SP, SL,
E
W - POWERLINK,
EI - EtherNet/IP,
E
P - PROFINET IRT
150
165 for SP, SL,
E
W - POWERLINK,
EI - EtherNet/IP,
E
P - PROFINET IRT