10
Valve size:
1 =10 2 = 16 3 = 25
www.atos.com
Proportional directional valves type DPZO-A*
two stage without position transducer, ISO 4401 sizes 10, 16 and 25
Table F170-20/E
DPZO
Piloted proportional
directional valve
Spool overlapping in central position, see section
3
:
1 = P, A, B, T positive overlapping (2)
3 =
P positive overlapping (2); A, B, T negative overlapping
Spool type
L = linear
S = progressive
D =as S, but with P-A = Q, P-B = Q/2
Spool size: 3, 5 and 9 = see section
3
Hydraulic options, see section
4
:
B = solenoid and integral electronics at
side of port B of the main stage;
D = internal drain
E = external pilot
G = pressure reducing valve for piloting
Electronics options for -AE execution,
see section
8
:
I =
current reference input (4÷20 mA)
Q = enable signal
Electronics options for -AES execution,
see section :
I =
current reference input (4÷20 mA)
Z = double power supply, enable and
fault (12 pins connector)
Series number
Synthetic fluids:
WG = water-glycol
PE = phosph. ester
AES PS 72-D15*/*/*---
1 MODEL CODE
F170
DPZO-AE-251
DPZO-AES-PS-271 (dotted line)
Configuration, see section
3
:
5 = external plus central position, spring centered
7 = 3 positions; spring centered
A = without position transducer
AE = as A plus integral electronics
AES = as A plus integral digital
electronics
AEG = as A plus integral digital
cycle generator (1)
Communication interfaces
(only for AES and AEG)
PS = Serial
BC = CANopen
(only for AES)
BP = PROFIBUS DP
(only for AES)
DPZO-A* are two stage proportional val-
ves without position transducer, which
provide both directional and non compen-
sated flow control according to the elec-
tronic reference signal.
They operate in association with electro-
nic drivers, see section
2
, which supply
the proportional valves with correct cur-
rent signal to align valve regulation to the
reference signal supplied to the electronic
driver.
They are available in different executions:
-A, without position transducer;
-AE, -AES as -A plus analogue (AE) or
digital (AES) integral electronics
.
-AEG, as A plus integral digital cycle
generator (see table G120).
The 4-way spool , sliding into a 5-
chambers body , is piloted in open loop
by the proportional pressure reducing
valve
type DHRZO.
The integral electronics
ensures factory
presetting, fine functionality plus valve-to-
valve interchangeability and simplified
wiring and installation.
The electronic main connector n is fully
interchangeable for –AE and –AES
executions.
Standard 7 pin main connector is used for
power supply, analog input reference and
monitor signals.
12 pin connector is used for AEG version
and for option /Z (AES).
Following communication interfaces
are
available for the digital -AES and -AEG
executions:
-PS, RS232 serial communication
interface. The valve reference signal is
provided with analogue commands via
the 7 (or 12) pins connector
.
• -BC, CANopen interface (only for -AES)
-BP, PROFIBUS DP interface (only for
-AES)
The valves with -BC and -BP interfaces
can be integrated into a fieldbus
communication network and thus digitally
operated by the machine control unit.
The coils are fully plastic encapsulated
(insulation class H) and valves have anti-
vibration, antishock and weather-proof
features.
Surface mounting: ISO 4401 size 10, 16
and 25.
Max flow respectively up to 160 l/min, 340
l/min and 680 l/min with valve differential
pressure
Δ
p = 30 bar, see section
3
.
Max pressure: 350 bar.
.
.
.
.
.
.
.
.
A
B
ELECTRONIC DRIVERS FOR DPZO-A*
2
Valve model
Data sheet
Drivers model E-MI-AC-0*F
G010
E-BM-AS-PS
G030
E-ME-AC-0*F
G035
-A -AES-AE
E-RP-AC-0*F
G100
E-RI-AE
G110
E-RI-AES
G115
-AEG
E-RI-AEG
G120
Note: For power supply and communication connector see section 17
E-BM-AC-0*F
G025
E-MI-AS-IR
G020
Communication connector
Main connector
Valve body
Main stage Spool
Pilot valve
Integral electronics
Note:
(1) For detailed description of AEG integral cycle generator, see table G120
(2) Overlapping = 20% of spool stroke for type
S
and
D
, 10% of spool stroke for type
L
Coils voltage (only for -A execution):
see section
6
:
- = standard 12 V
DC
coil
6 = with 6 V
DC
coil
18 = with 18 V
DC
*
3
HYDRAULIC CHARACTERISTICS (based on mineral oil ISO VG 46 at 50 °C)
Valve model
Spool overlapping
Spool type and size
DPZO-1 DPZO-2 DPZO-3
Max flow (1) [l/min]
at
Δ
p = 10 bar
at
Δ
p = 30 bar
max permissible flow
100
160
180
100
160
180
100 : 60
160 : 100
180 : 110
130
225
500
130 : 80
225 : 135
500 : 300
200
340
710
180
310
640
180 : 130
310 : 225
640 : 460
390
680
1350
360
620
1250
360 : 220
620 : 380
1250 : 760
S5 D5 S3 D3 L5 S5 D5 L5 S5 D5L5
Hydraulic symbols
*71
*73
*51
*53
aa b
b
*51/B
a
*53/B
abb
4
HYDRAULIC OPTIONS
4.1 Option /B Solenoid (for valve configuration *5*) and integral electronics at side of port A.
4.2 Pilot and drain configuration -The pilot / drain configuration can be modified as shown in the table E080 section 12.
The valve’s standard configuration provides internal pilot and external drain. For different pilot / drain configuration select:
Option /E External pilot (through port X). Option /D Internal drain.
Option /G Pressure reducing valve with fixed setting (= 40 bar for DPZO-1 and -2; 100 bar for DPZO-3) installed between pilot valve and main body.
It is advisable for valves with internal pilot in case of system pressure higher than 200 bar. This option is standard for DPZO-L*-1.
DPZO-A* proportional valves are CE marked according to the applicable Directives (e.g. Immunity/Emission EMC Directive and Low Voltage Directive).
Installation, wirings and start-up procedures must be performed according to the general prescriptions shown in table F003 and in the installation notes
supplied with relevant components.
The electrical signals of the valve (e.g. monitor signals) must not be directly used to activate safety functions, like to switch-ON/OFF the machine’s safety
components, as prescribed by the European standards (Safety requirements of fluid technology systems and components-hydraulics, EN-982).
5
GENERAL NOTES
7
CONNECTIONS FOR -A EXECUTION
Signal description
SUPPLY
SUPPLY
GND
PIN
1
2
3
SOLENOID POWER SUPPLY CONNECTOR
1
2
3
8 ANALOG INTEGRAL DRIVERS -AE - OPTIONS
Standard driver execution provides on the 7 pin main connector:
Power supply
- 24VDC must be appropriately stabilized or rectified and filtered; a 2,5 A safety fuse is required in series to the driver power supply.
Apply at least a 10000 μF/40 V capacitance to single phase rectifiers or a 4700 μF/40 V capacitance to three phase rectifiers
Reference input signal
- analog differential input with ±10 VDC nominal range (pin D,E), proportional to desired coil current.
Monitor output signal
- analog output signal proportional to the actual valve’s coil current (1V monitor = 1A coil current)
Following options are available to adapt standard execution to special application requirements:
8.1 Option /I
It provides the 4÷20 mA current reference signal instead of the standard ±10 V
DC. Monitor output signal is still the standard ±10 VDC.
It is normally used in case of long distance between the machine control unit and the valve or where the reference signal can be affected by electrical
noise; the valve functioning is disabled in case of reference signal cable breakage.
8.2 Option /Q
It provides the possibility to enable or disable the valve functioning without cutting the power supply (the valve functioning is disabled but the driver cur-
rent output stage is still active). To enable the driver supply a 24V
DC on the enable input signal.
8.3 Possible combined options: /IQ
6
OPTIONS FOR -A EXECUTION
6.1 Option /6
6
VDC coil instead of standard 12 VDC, to be used in case of power supply 12 VDC
6.2 Option /18
18
VDC coil instead of standard 12 VDC, to be used with electronic drivers not supplied by Atos
Hysteresis [%]
Repeatability
Response time [ms]
Pressure limits [bar]
ports P, A, B, X = 350; T = 250 (5 for option /D); Y = 5
Notes:
Above performance data refer to valves coupled with Atos electronic drivers, see section
2
.
In case of long time shutdown of the hydraulic supply to the pilot valve, the driver has to be switched off to avoid its overheating.
The flow regulated by the directional proportional valves is not pressure compensated, thus it is affected by the load variations.To keep costant the
regulated flow under different load conditions, modular pressure compensators are available (see tab. D150).
(1) For different
Δ
p, the max flow is in accordance to the diagrams in section 14.2
< 100
< 120
< 80
5%
± 1%
1, 3
1, 3
1, 3
CURRENT
TO COIL S2
REGULATIONS AND SWITCHES
7 PIN - STANDARD
MAIN CONNECTOR
BIAS
SCALE
RAMPS
B2
B1
S2
S1
positive bias adjust
H
H
H
H
H
(driver view)
negative bias adjust (only for double solenoid valves)
positive scale adjust
negative scale adjust (only for double solenoid valves)
B1:
B2:
S1:
S2:
(remove the rear cover)
SW
9 ANALOG INTEGRAL DRIVERS -AE - MAIN FUNCTIONS AND ELECTRONIC CONNECTIONS
PIN SIGNAL
TECHNICAL SPECIFICATIONS
NOTES
A V+ Power supply 24 VDC for solenoid power stage and driver logic Input - power supply
B V0 Power supply 0 VDC for solenoid power stage and driver logic Gnd - power supply
C
(1)
AGND Ground - signal zero for MONITOR signal Gnd - analog signal
ENABLE Enable (24 VDC) or disable (0 VDC) the driver (for /Q option) Input - on/off signal
D INPUT+
Reference analog differential input: ±10 VDC maximum range (4 ÷ 20 mA for /I option)
For single solenoid valves the reference input is 0÷+10 V
DC (4 ÷ 20 mA for /I option)
For double solenoid valves the reference input is ±10 V
DC (4 ÷ 20 mA for /I option)
Input - analog signal
E INPUT -
F MONITOR
Monitor analog output: ±10 VDC maximum range
Output - analog signal
G EARTH Internally connected to the driver housing
Note: (1) with /Q option ENABLE signal replaces AGND on pin C; MONITOR signal is reffered to pin B.
A minimum time of 60ms to 160ms have be considered between the driver energizing with the 24 V
DC power supply and when the valve is ready
to operate. During this time the current to the valve coils is switched to zero
Selector SW
Dither frequency
[Hz]
SW1 SW2 SW3 SW4
ON
ON
ON
ON ON
ON ON
ON ON ON
ON ON ON
ON ON ON
ON ON ON
ON ON ON ON
The dither frequency is factory pre-
set at 200 Hz and its regulation may
be adjusted after contact with Atos
technical department
100
130
160
200 (Standard)
230
270
300
380
430
470
500
(only for double
solenoid valves)
H
H
RU
RD
ramp for increasing reference signal
ramp for decreasing reference signal
RU:
RD:
9.1 ELECTRONIC CONNECTIONS - 7 PIN MAIN CONNECTORS
10 DIGITAL INTEGRAL DRIVERS -AES - OPTIONS
Standard driver execution provides on the 7 pin main connector:
Power supply
- 24VDC must be appropriately stabilized or rectified and filtered; a 2,5 A safety fuse is required in series to each driver power supply
Apply at least a 10000 μF/40 V capacitance to single phase rectifiers or a 4700 μF/40 V capacitance to three phase rectifiers.
Reference input signal
- analog differential input with ±10VDC nominal range (pin D,E), proportional to desired coil current.
Monitor output signal
- analog output signal proportional to the actual valve’s coil current (1V monitor = 1A coil current)
Following options are available to adapt standard execution to special application requirements:
10.1 Option /I
It provides 4÷20 mA current reference signal instead of the standard ±10 V
DC. Monitor output signal is still the standard 0÷10 VDC.
It is normally used in case of long distance between the machine control unit and the valve or where the reference signal can be affected by electrical
noise; the valve functioning is disabled in case of reference signal cable breakage.
10.2 Option /Z
It provides on a 12 pin main connector the above standard features plus:
Logic power supply
Option /Z provides separate power supply for the solenoid (pin 1, 2) and for the digital electronic circuits (pin 9, 10).
Cutting solenoid power supply allows to interrupt the valve functioning but keeping energized the digital electronics thus avoiding fault conditions of the
machine fieldbus controller. This condition allows to realize safety systems in compliance with European Norms EN13849-1 (ex EN954-1).
Enable Input Signal
To enable the driver, supply a 24V
DC on pin 3 referred to pin 2: when the Enable signal is set to zero the valve functioning is disabled (zero current to
the solenoid) but the driver current output stage is still active. This condition does not comply with European Norms EN13849-1 (ex EN954-1).
Fault Output Signal
Fault output signal indicates fault conditions of the driver (solenoid short circuits/not connected, reference signal cable broken for 4÷20mA input, etc.).
Fault presence corresponds to 0
VDC
, normal working corresponds to 24
VDC (pin 11 referred to pin 2)
: Fault status is not affected by the Enable input signal
10.3 Possible combined options: /IZ
F170
dither frequency selector (see table beside)
SW:
ON
OFF
Assembly position Any position
Subplate surface finishing Roughness index, flatness ratio 0,01/100 (ISO 1101)
Ambient temperature -20°C ÷ +70°C for -A execution; -20°C ÷ +60°C for -AE and -AES executions
Fluid Hydraulic oil as per DIN 51524 ... 535 for other fluids see section
1
Recommended viscosity 15 ÷100 mm
2
/s at 40°C (ISO VG 15÷100)
Fluid contamination class ISO 18/15 achieved with in line filters of 10 μm and β10 _>75 (recommended)
Fluid temperature -20°C +60°C (standard and /WG seals) -20°C +80°C (/PE seals)
13 MAIN CHARACTERISTICS OF PROPORTIONAL DIRECTIONAL VALVES TYPE DPZO-A*
Coil voltage
Coil resistance R at 20°C 3 ÷ 3,3 Ω 2 ÷ 2,2 Ω 13 ÷ 13,4 Ω
Max. solenoid current 1,9 A 2,35 A 0,9 A
Max. power 30 Watt
Protection degree (CEI EN-60529)
IP65 for -A execution; IP65÷67 for -AE and -AES executions, depending to the connector type, see sect. 17
Relative duty factor Continuous rating (ED=100
%)
12 V
DC
coil 6 V
DC
coil 18 V
DC
coil
11 DIGITAL INTEGRAL DRIVERS -AES - MAIN FUNCTIONS AND ELECTRONIC CONNECTIONS
COMMUNICATION
CONNECTOR
12 PIN - OPTION /Z
7 PIN - STANDARD
5 PIN reverse key
PROFIBUS DP (-BP)
5 PIN
Serial (-PS) or
CANopen (-BC)
RAMPS
BIASSCALE
LINEARIZATION
MAIN CONNECTOR
(driver view)
(driver view)
CURRENT TO COIL S2
(for double solenoid
valves)
(driver view)
11.2 ELECTRONIC CONNECTIONS - 5 PIN COMMUNICATION CONNECTORS
11.1 ELECTRONIC CONNECTIONS - 7 & 12 PIN MAIN CONNECTORS
-PS Serial -BC CANopen -BP PROFIBUS DP
PIN SIGNAL TECHNICAL SPECIFICATION SIGNAL TECHNICAL SPECIFICATION SIGNAL TECHNICAL SPECIFICATION
1 NC do not connect CAN_SHLD Shield +5V for termination
2 NC do not connect NC do not connect LINE-A Bus line (high)
3 RS_GND Signal zero data line CAN_GND Signal zero data line DGND data line and termination Signal zero
4 RS_RX Valves receiving data line CAN_H Bus line (high) LINE-B Bus line (low)
5 RS_TX Valves transmitting data line CAN_L Bus line (low) SHIELD
Standard
7pin
/Z option
12pin
SIGNAL TECHNICAL SPECIFICATIONS NOTES
A 1 V+
Power supply 24 VDC for solenoid power stage (and for driver logic on 7 pin connection)
Input - power supply
Gnd - power supply
B 2 V0 Power supply 0 VDC for solenoid power stage
(and for driver logic on 7 pin connection)
- 3 ENABLE Enable (24 VDC) or disable (0 VDC) the driver Input - on/off signal
D 4 INPUT+
Reference analog input: ±10 VDC maximum range (4 ÷ 20 mA for /I option)
For single solenoid valves the reference input is 0÷+10 V
DC (4 ÷ 20 mA for /I option)
For double solenoid valves the reference input is ±10 V
DC (4 ÷ 20 mA for /I option)
standard: differential input; /Z option: common mode INPUT+ referred to AGND
Input - analog signal
E - INPUT -
C 5 AGND
Ground - signal zero for MONITOR signal
signal zero for INPUT+ signal (only for /Z option)
Gnd - analog signal
F 6 MONITOR Monitor analog output: ±10 VDC maximum range Output - analog signal
- 7 NC do not connect
- 8 NC do not connect
- 9 VL+ Power supply 24 VDC for driver logic
Input - power supply
Gnd - power supply
- 10 VL0 Power supply 0 VDC for driver logic
- 11 FAULT Fault (0 VDC) or normal working (24 VDC) Output - on/off signal
G PE EARTH Internally connected to the driver housing
12
SOFTWARE TOOLS
Note: A minimum time of 270 to 340 ms have be considered between the driver energizing with the 24 VDC power supply and when the valve is ready
to operate. During this time the current to the valve coils is switched to zero.
The functional parameters of digital valves, as the bias, scale ramp and linearization of the regulation characteristic, can be easily set and optimized with the
Atos E-SW programming software, available in three different versions according to the driver’s communication interfacing: E-SW-PS (Serial), E-SW-BC
(CANopen) and E-SW-BP (PROFIBUS DP).
A proper connection is required between the PC and the electronic driver communication port: for a more detailed description of software interface, PC
requirements, adapters, cables and terminators, please see table G500.
Proportional valves with fieldbus communication interface (-BC and -BP) can be directly managed by the machine control unit; it is required to implement
in the machine control the standard communication as described in the user manuals supplied with the relevant programming software. For detailed
description of available fieldbus feature, see table G510.
On first supply of the E-SW software, it is required to apply for the registration in the Atos download area: www.download.atos.com
Once the registration is completed, the password will be sent by email.
The software remains active for 10 days from the installation date and then it stops until the user inputs his password.
With the password you can also download, in your personal area, the latest releases of the Atos software, manuals, drivers and configuration files.
6
7
14
DIAGRAMS (based on mineral oil ISO VG 46 at 50 °C)
14.1 Regulation diagrams
DPZO-1:
1 = linear spool L5
2 = differential spool S5, D5
DPZO-2:
3 = progressive spool S3, D3
4 = progressive spool S5, D5
5 = linear spool L5
DPZO-3:
6 = linear spool L5
7 = progressive spool S5, D5
14.2 Flow /Δp diagram
Stated at 100% of valve stroke
DPZO-1:
1 = spool L5, S5, D5
DPZO-2:
2 = spool L5, S5, D5
3 = spool S3, D3
DPZO-3:
4 = spool L5, S5, D5
F170
Flow rate [l/min]
Valve pressure drop Δp [bar]
,Flow rate [l/min]
Valve pressure drop Δp [bar]
1
2
3
4
14.3 Operation as throttle valve
Single solenoid valves (*51) can be
used as simple throttle valves:
Pmax = 250 bar
For this application, the use of valve -T,
-TE or -TES (see tab. F172 and F175) is
advisable (consult our technical office)
Note:
1)
Hydraulic configuration vs. reference signal:
for double solenoid valves (also for option /B)
Reference signal 0 ÷+10 V
P n A / B n T
12÷20 mA
Reference signal 0 ÷-10 V
P n B / A n T
4÷12 mA
Stroke [% of max]
Max flow [l/min] at Δp = 10 bar
X = Threshold for bias activation depending to the valve type and amplifier type
Reference signal [V]Reference signal [V]
Stroke [% of max]
Max flow [l/min] at Δp = 10 bar
1
2
5
4
3
Max flow [l/min]
320 650 1300
151-L5 251-L5 351-L5
DPZO-*-
Δp [bar]
30 30 30
15 INSTALLATION DIMENSIONS FOR DPZO-1 AND DPZO-2 [mm]
DPZO-A(*)-1
ISO 4401: 2005
Mounting surface: 4401-05-05-0-05 (see table P005)
Fastening bolts:
4 socket head screws M6x40 class 12.9
Tightening torque = 15 Nm
Seals: 5 OR 2050; 2 OR 108
Diameter of ports A, B, P, T: Ø = 11 mm;
Diameter of ports X, Y: Ø = 5 mm;
DPZO-A(*)-2
ISO 4401: 2005
Mounting surface: 4401-07-07-0-05 (see table P005)
Fastening bolts:
4 socket head screws M10x50 class 12.9
Tightening torque = 70 Nm
2 socket head screws M6x40 class 12.9
Tightening torque = 15 Nm
Seals: 4 OR 130; 3 OR 109/70
Diameter of ports A, B, P, T: Ø = 20 mm;
Diameter of ports X, Y: Ø = 7 mm;
Mass [kg]
DPZO-*-15*
7,7
A AE, AES
8,6
8,1
9
DPZO-*-17*
Mass [kg]
DPZO-*-25*
11,9
A AE, AES
12,8
12,3
13,2
DPZO-*-27*
DPZO-A-1
DPZO-AE-1 DPZO-AES-*-1
DPZO-A-2
DPZO-AE-2 DPZO-AES-*-2
(dotted line = double solenoid version)
SP-666
y
SP-ZH-7P or SP-ZM-7P
SP-ZH-7P or SP-ZM-7P
SP-ZH-5P/BP (for -BP)
SP-ZH-5P (for -PS and -BC)
= 12 pin connector SP-ZH-12P for option /Z
y
-AES EXECUTION
NOTE:
For option /B the proportional solenoid and the electronics (in case of execution -AE and -AES) are at side of port B of the main stage.
= 12 pin connector SP-ZH-12P for option /Z
y
-AES EXECUTION
NOTE:
For option /B the proportional solenoid and the electronics (in case of execution -AE and -AES) are at side of port B of the main stage.
SP-666
SP-ZH-7P or SP-ZM-7P
SP-ZH-7P or SP-ZM-7P
SP-ZH-5P/BP (for -BP)
SP-ZH-5P (for -PS and -BC)
y
(dotted line = double solenoid version)
05/09
16 INSTALLATION DIMENSIONS FOR DPZO-3 [mm]
DPZO-A(*)-3
ISO 4401: 2005
Mounting surface: 4401-08-08-0-05 (see table P005)
Fastening bolts:
6 socket head screws M12x50 class 12.9
Tightening torque = 125 Nm
Seals: 4 OR 4112; 3 OR 3056
Diameter of ports A, B, P, T: Ø = 24 mm;
Diameter of ports X, Y: Ø = 7 mm;
Mass [kg]
DPZO-*-35*
17,1
A AE, AES
18
17,5
18,4
DPZO-*-37*
DPZO-A-3
DPZO-AE-3 DPZO-AES-3
SP-666
MODEL CODES OF POWER SUPPLY AND COMMUNICATION CONNECTORS (to be ordered separately)
17
connectors supplyed with the valve
VALVE VERSION
CONNECTOR CODE
SP-ZH-7P SP-ZM-7P SP-ZH-12P SP-ZH-5P SP-ZH-5P/BP
PROTECTION DEGREE
IP65 IP67 IP67 IP65 IP67 IP67
-A -AE, -AES
-AES/Z
-AEG
-Serial (-PS)
or CANopen (-BC)
PROFIBUS DP (-BP)
DATA SHEET
K500 G110, G115, K500
G115, K500
SP-666
SP-ZH-7P or SP-ZM-7P
SP-ZH-7P or SP-ZM-7P
SP-ZH-5P/BP (for -BP)
SP-ZH-5P (for -PS and -BC)
y
= 12 pin connector SP-ZH-12P for option /Z
y
-AES EXECUTION
NOTE:
For option /B the proportional solenoid and the electronics (in case of execution -AE and -AES) are at side of port B of the main stage.
(dotted line = double solenoid version)