Notes: above performance data refer to valves coupled with Atos electronic drivers, see section .
the flow regulated by the directional proportional valves is not pressure compensated, thus it is affected by the load variations.To keep costant the
regulated flow under different load conditions, modular pressure compensators are available (see tab. D150).
(1) For different
D
p, the max flow is in accordance to the diagrams in sections 7.2 and 8.2
(2) 0-100% step signal
DHZE and DKZE proportional valves are CE marked according to the applicable
Directives (e.g. Immunity/Emission EMC Directive and Low Voltage Directive).
Installation, wirings and start-up procedures must be performed according to
the general prescriptions shown in table F003 and in the installation notes sup-
plied with relevant components.
5
GENERAL NOTES
6
CONNECTIONS
Signal description
SUPPLY
SUPPLY
GND
PIN
1
2
3
SOLENOID POWER SUPPLY CONNECTOR
1
2
3
Valve model
DHZE DKZE
Spool type and size
Nominal flow (1) [l/min]
at
D
p = 10 bar (P-T)
at
D
p = 30 bar (P-T)
at
D
p = 70 bar (P-T)
Response time (2) [ms]
Hysteresis [%]
Repeatability [%]
< 30
< 40
45
80
120
18
30
45
S3, L3, D3
S
3, L3, D3
28
50
70
S5, L5, D5
60
105
160
S5, L5, D5
Pressure limits [bar]
ports P, A, B = 350; T = 210
ports P, A, B = 315; T = 210
1
2
3
L14
4,5
8
12
L1
2
ELECTRONIC DRIVERS
Max. power 30W 35W
Insulation class H (180°) Due to the occuring surface temperatures of the solenoid coils, the European standards
ISO 13732-1 and EN982 must be taken into account
Protection degree to DIN EN60529 IP67
Duty factor Continuous rating (ED=100%)
Certification cURus North American Standard
3
M
AIN CHARACTERISTICS - based on mineral oil ISO VG 46 at 50 °C
Coil code DHZE DKZE
Coil resistance R at 20°C 3 ÷ 3,3
W
2 ÷ 2,2
W
13 ÷ 13,4
W
3,8 ÷ 4,1
W
2,2 ÷ 2,4
W
12 ÷ 12,5
W
Max. solenoid current 2,2 A 2,75 A 1 A 2,6 A 3,25 A 1,2 A
s
tandard
o
ption /6
o
ption /18 standard option /6 option /18
Assembly position Any position
Subplate surface finishing Roughness index, Ra 0,4 flatness ratio 0,01/100 (ISO 1101)
MTTFd valves according to EN ISO 13849 150 years, see technical table P007
Ambient temperature range standard = -20°C ÷ +70°C, /BT option = -40°C ÷ +60°C
Storage temperature range standard = -20°C ÷ +80°C, /BT option = -40°C ÷ +70°C
4
SEALS AND HYDRAULIC FLUID - for other fluids not included in below table, consult our technical office
≤ 5 [% of max regulation]
± 1 [% of max regulation]
Seals, recommended fluid temperature
NBR seals (standard) = -20°C ÷ +60°C, with HFC hydraulic fluids = -20°C ÷ +50°C
FKM seals (/PE option) = -20°C ÷ +80°C
HNBR seals (/BT option) = -40°C ÷ +60°C, with HFC hydraulic fluids = -40°C ÷ +50°C
Recommended viscosity 20 ÷ 100 mm
2
/s - max allowed range 15 ÷ 380 mm
2
/s
Fluid contamination class
ISO 4406 class 20/18/15 NAS 1638 class 9, in line filters of 10 mm (b10 _>75 recommended)
Hydraulic fluid Suitable seals type Classification Ref. Standard
Mineral oils
NBR, FKM, HNBR HL, HLP, HLPD, HVLP, HVLPD DIN 51524
Flame resistant without water FKM HFDU, HFDR
ISO 12922
Flame resistant with water NBR, HNBR HFC
D
rivers model
E
-MI-AC
E
-MI-AS-IR
E
-BM-AC
E
-BM-AS-PS
E
-BM-AES
E
-ME-AC
Type analog digital analog digital digital analog
Voltage supply (V
DC
)
12 24 12 24 12 24 12 24 24 24
Valve coil option /6 std /6 std /6 std /6 std std std
F
ormat
D
IN 43650
plug-in to solenoid
D
IN 43700
UNDECAL
D
IN-rail panel
E
UROCARD
D
ata sheet
G
010
G
020
G
025
G
030
G
S050
G
035