Series number
www.atos.com
Table F150-3/E
DHZE-A, DKZE-A
Open-loop direct operated proportional
directionalvalves with threaded type
proportional solenoids, certified
according to North American standard
cURus.
They operate in association with electronic
drivers, see section
, which supply the
proportional valves with proper current to
align the valve regulation to the reference
signal supplied to the electronic driver.
The spools are available with linear L,
progressive S or differential D flow
characteristics.
The valve body is 3 chambers type for
DHZE and 5 chambers type for DKZE.
The solenoid coils are plastic encapsulated
with insulation class H and they are
available with different nominal resistances
depending to the voltage supply (12 VDC
or 24 VDC) and to the electronic driver
type, see section and .
Size: 06 and 10
Max flow: up to 70 and 160 l/min
Max pressure: 350 bar (DHZE)
315 bar (DKZE)
DHZE = size 06
DKZE = size 10
A = open loop
Valve size - ISO 4401
0 = size 06 (DHZE)
1 = size 10 (DKZE)
1
MODEL CODE
F150
DKZE-A-15*
Proportional directional valves
direct operated, open loop
Valve body
Spool
Proportional solenoid
Digital electronic driver E-MI-AS-IR (to be ordered separately)
Manual override
Coil option (only for -A execution)
see section and :
- = standard coil for 24V
DC
Atos drivers
6 = optional coil for 12V
DC
Atos drivers
18 = optional coil for 24V
DC
low current drivers
DHZE-A-07*
A B
A B
DHZE
/ /- -
S 5 * *
** *
A 0
71
Seals material,
see section :
- =
NBR
PE = FKM
BT = HNBR
- /
*
Coils with special connectors, see section
- = omit for standard DIN connector
J = AMP Junior Timer connector
K = Deutsch connector
S = Lead Wire connection
10
-
Hydraulic options
B = solenoid side of port A (only for valve configuration 5)
Auxiliary hand lever
only for DHZE with spool type S3, S5, D3, D5, L3, L5
It allows to operate the valve in absence of electrical power
supply, see tech. table E138
MO = horizontal hand lever
MV = vertical hand lever
BMO = horizontal hand lever installed at side of port A
BMV = vertical hand lever installed at side of port A
71 =
73 =
51 =
53 =
b
b
b
a
a
a
a b
Configuration:
Standard
Option /B
Spool type - regulating characteristics:
L = linear S = progressive
D = differential-progressive
P-A = Q, B-T = Q/2
P-B = Q/2, A-T = Q
Nominal flow (l/min) at Dp 10 bar P-T
14 (L)
1
-
Spool size:
DHZE =
DKZE =
1 (L)
4,5
-
3 (L,S,D)
17
45
5 (L,S,D)
28
60
Notes: above performance data refer to valves coupled with Atos electronic drivers, see section .
the flow regulated by the directional proportional valves is not pressure compensated, thus it is affected by the load variations.To keep costant the
regulated flow under different load conditions, modular pressure compensators are available (see tab. D150).
(1) For different
D
p, the max flow is in accordance to the diagrams in sections 7.2 and 8.2
(2) 0-100% step signal
DHZE and DKZE proportional valves are CE marked according to the applicable
Directives (e.g. Immunity/Emission EMC Directive and Low Voltage Directive).
Installation, wirings and start-up procedures must be performed according to
the general prescriptions shown in table F003 and in the installation notes sup-
plied with relevant components.
5
GENERAL NOTES
6
CONNECTIONS
Signal description
SUPPLY
SUPPLY
GND
PIN
1
2
3
SOLENOID POWER SUPPLY CONNECTOR
1
2
3
Valve model
DHZE DKZE
Spool type and size
Nominal flow (1) [l/min]
at
D
p = 10 bar (P-T)
at
D
p = 30 bar (P-T)
at
D
p = 70 bar (P-T)
Response time (2) [ms]
Hysteresis [%]
Repeatability [%]
< 30
< 40
45
80
120
18
30
45
S3, L3, D3
S
3, L3, D3
28
50
70
S5, L5, D5
60
105
160
S5, L5, D5
Pressure limits [bar]
ports P, A, B = 350; T = 210
ports P, A, B = 315; T = 210
1
2
3
L14
4,5
8
12
L1
2
ELECTRONIC DRIVERS
Max. power 30W 35W
Insulation class H (180°) Due to the occuring surface temperatures of the solenoid coils, the European standards
ISO 13732-1 and EN982 must be taken into account
Protection degree to DIN EN60529 IP67
Duty factor Continuous rating (ED=100%)
Certification cURus North American Standard
3
M
AIN CHARACTERISTICS - based on mineral oil ISO VG 46 at 50 °C
Coil code DHZE DKZE
Coil resistance R at 20°C 3 ÷ 3,3
W
2 ÷ 2,2
W
13 ÷ 13,4
W
3,8 ÷ 4,1
W
2,2 ÷ 2,4
W
12 ÷ 12,5
W
Max. solenoid current 2,2 A 2,75 A 1 A 2,6 A 3,25 A 1,2 A
s
tandard
o
ption /6
o
ption /18 standard option /6 option /18
Assembly position Any position
Subplate surface finishing Roughness index, Ra 0,4 flatness ratio 0,01/100 (ISO 1101)
MTTFd valves according to EN ISO 13849 150 years, see technical table P007
Ambient temperature range standard = -20°C ÷ +70°C, /BT option = -40°C ÷ +60°C
Storage temperature range standard = -20°C ÷ +80°C, /BT option = -40°C ÷ +70°C
4
SEALS AND HYDRAULIC FLUID - for other fluids not included in below table, consult our technical office
5 [% of max regulation]
± 1 [% of max regulation]
Seals, recommended fluid temperature
NBR seals (standard) = -20°C ÷ +60°C, with HFC hydraulic fluids = -20°C ÷ +50°C
FKM seals (/PE option) = -20°C ÷ +80°C
HNBR seals (/BT option) = -40°C ÷ +60°C, with HFC hydraulic fluids = -40°C ÷ +50°C
Recommended viscosity 20 ÷ 100 mm
2
/s - max allowed range 15 ÷ 380 mm
2
/s
Fluid contamination class
ISO 4406 class 20/18/15 NAS 1638 class 9, in line filters of 10 mm (b10 _>75 recommended)
Hydraulic fluid Suitable seals type Classification Ref. Standard
Mineral oils
NBR, FKM, HNBR HL, HLP, HLPD, HVLP, HVLPD DIN 51524
Flame resistant without water FKM HFDU, HFDR
ISO 12922
Flame resistant with water NBR, HNBR HFC
D
rivers model
E
-MI-AC
E
-MI-AS-IR
E
-BM-AC
E
-BM-AS-PS
E
-BM-AES
E
-ME-AC
Type analog digital analog digital digital analog
Voltage supply (V
DC
)
12 24 12 24 12 24 12 24 24 24
Valve coil option /6 std /6 std /6 std /6 std std std
F
ormat
D
IN 43650
plug-in to solenoid
D
IN 43700
UNDECAL
D
IN-rail panel
E
UROCARD
D
ata sheet
G
010
G
020
G
025
G
030
G
S050
G
035
7
D
IAGRAMS FOR DHZE (based on mineral oil ISO VG 46 at 50 °C)
7
.1 Regulation diagrams
1
= linear spool L14
2
= linear spool L1
3
= linear spool L3
4
= progressive spool S3, D3
5
= linear spool L5
6
= progressive spool S5, D5
F150
7
.2 Operating limits
7
= spool L14
8 = spool L1
9
= spool L3, S3, D3
1
0 = spool L5, S5, D5
Max flow
Dp= 30bar [l/min]
SPOOL TYPE
L3 S3
60
L5 S5
100
120
DHZE
DKZE
150
8
D
IAGRAMS FOR DKZE (based on mineral oil ISO VG 46 at 50 °C)
9 OPERATION AS THROTTLE VALVE
Max flow [l/min] at
D
P = 30 bar
Stroke [% of max]
1
2
4
3
Valve pressure drop
D
P [bar]
Flow rate [l/min]
1
2
8
.1 Regulation diagrams
1
= linear spool L3
2
= progressive spool S3, D3
3
= linear spool L5
4 = progressive spool S5, D5
8.2 Operating limits
1 = spool L3, S3, D3
2
= spool L5, S5, D5
Reference signal [V]
X = Threshold for bias activation depending to the valve type and amplifier type
Single solenoid valves (DHZE-A-051 -
DKZE-A-151) can be used as simple
throttle valves:
Pmax = 210 bar
L1
16
-
L14
4
-
10
COILS WITH SPECIAL CONNECTORS
Options -J
Coil type COZEJ (DHZE)
Coil type CAZEJ (DKZE)
AMP Junior Timer connector
Protection degree IP67
Options -K
Coil type COZEK (DHZE)
Coil type CAZEK (DKZE)
Deutsch connector, DT-04-2P male
Protection degree IP67
Options -S
Coil type COZES (DHZE)
Coil type CAZES (DKZE)
Lead Wire connection
Cable lenght = 180 mm
Max flow [l/min] at
D
p = 30 bar
Max flow [l/min] at
D
p = 30 bar
Stroke [% of max] Stroke [% of max]
R
eference signal [V]
X
= Threshold for bias activation depending to the valve type and amplifier type
R
eference signal [V]
2
4
5
3
1
6
Valve pressure drop Dp [bar]
F
low rate [l/min]
8
7
9
10
1
1 INSTALLATION DIMENSIONS FOR DHZE and DKZE [mm]
ISO 4401: 2005
M
ou
n
ting surface: 4401-03-02-0-05
(
see table P005)
F
astening bolts: 4 socket head screws M5x30 class 12.9
Tightening torque = 8 Nm
S
eals: 4 OR 108
D
iameter of ports A, B, P, T: Ø 7,5 mm (max)
D
HZE-A-07
ISO 4401: 2005
Mou
nting surface: 4401-05-04-0-05
(see table P005)
Fastening bolts: 4 socket head screws M6x40 class 12.9
Tightening torque = 15 Nm
Seals: 5 OR 2050
Diameter of ports A, B, P, T: Ø 11,2 mm (max)
Mass: 4,5 kg
DKZE-A-15 DKZE-A-17
Mass: 6,1 kg
M
ass: 1,5 kg
Mass: 2 kg
Note: for option /B the solenoid is at side of port A (only for DHZE-A-05 and DKZE-A-15)
666
666
01/17
M
ass: 2 kg
Mass: 3 kg
D
HZE-A-05
E-MI-AS-IR E-MI-AS-IR
666 666
E-MI-AS-IRE-MI-AS-IR
Mass: 5 kg
Mass: 7 kg
D
HZE-A-07
(with digital driver
E-MI-AS-IR)
D
HZE-A-05
(with digital driver
E-MI-AS-IR)
DKZE-A-15
(with digital driver
E-MI-AS-IR)
DKZE-A-17
(with digital driver
E-MI-AS-IR)
21.5
10.5
5
0.5
7369
1
52.5
23.5
73
69
73
215
4
5
==
81.5
47.5
28.5
21.5
1
0.5
50.5
7
369
1
52.5
23.5
73
69
73
215
45
==
90
47.5
1
1
11
1
1
26.5
92.2
100
30
10
27
==
26.5
92.2
100
100
70
==
26.5
73
106.5
26.5
92.2
100
30
10
27
==
26.5
92.2
100
100
26.5
70
==
73
114