standard
option /6
optional coil to be used with
Atos drivers with power supply
12 V
DC
option /18
optional coil to be used with elec-
tronic drivers not supplied by
Atos, with power supply 24 VDC
and max current limited to 1A
4
≤70
≤1,5
≤3
≤2
3
HYDRAULIC CHARACTERISTICS (based on mineral oil ISO VG 46 at 50 °C)
Hydraulic symbols
Valve model
Max regulated pressure (Q = 1 l/min) [bar]
Min. regulated pressure (Q = 1 l/min) [bar]
Max. pressure at port P [bar]
Max. pressure at port T [bar]
Max. flow [l/min]
Response time 0-100% step signal (1)
[ms]
(depending on installation)
Hysteresis [% of the max pressure]
Linearity [% of the max pressure]
Repeatability [% of the max pressure]
RZME-A
CART RZME-A
50
0,3
100
0,5
210
0,5
315
1
350
1,5
350
210
Above performance data refer to valves coupled with Atos electronic drivers, see section
.
Coil resistance R at 20°C 3 ÷ 3,3
Ω
2 ÷ 2,2
Ω
13 ÷ 13,4
Ω
Max. solenoid current 2,2 A 2,75 A 1 A
Max. power 30 Watt
Protection degree (CEI EN-60529)
IP65
Duty factor Continuous rating (ED=100%)
Certification cURus North American Standard
4
MAIN CHARACTERISTICS, SEALS AND HYDRAULIC FLUID - for other fluids not included in below table, consult our technical office
Coil code
Mineral oils
Hydraulic fluid
NBR, FKM, HNBR
FKM
NBR, HNBR
DIN 51524
ISO 12922
HL, HLP, HLPD, HVLP, HVLPD
HFDU, HFDR
HFC
Suitable seals type
Classification Ref. Standard
Flame resistant without water
Flame resistant with water
NBR seals (standard) = -20°C ÷ +60°C, with HFC hydraulic fluids = -20°C ÷ +50°C
Seals, recommended fluid temperature FKM seals (/PE option)= -20°C ÷ +80°C
HNBR seals (/BT option)= -40°C ÷ +60°C, with HFC hydraulic fluids = -40°C ÷ +50°C
Recommended viscosity 15÷100 mm
2
/s - max allowed range 2.8 ÷ 500 mm
2
/s
Fluid contamination class
ISO 4406 class 21/19/16 NAS 1638 class 10, achievable with in line filters - 25 μm (β10 _>75 recommended)
Assembly position / location Any position
Subplate surface finishing (RZME) Roughness index Ra 0,4 - flatness ratio 0,01/100 (ISO 1101)
Flow direction As shown in the symbols of table
Ambient temperature Standard execution = -30°C ÷ +70°C; /PE option = -20°C ÷ +70°C; /BT option = -40°C ÷ +70°C
(1) Average value response time; the pressure variation in consequence of a modification of the reference input signal to the valve is affected by the
stiffness of the hydraulic circuit: greater is the stiffness of the circuit, faster is the dynamic response.