Pressure switches type MAP
with fixed differential
MAP pressure switches produce an
electrical make/break contact which is
triggered when pressure in the hydrau-
lic circuit reaches a given setting.
Fluid pressure in the circuit operates a
piston 쩸 flitted with adjustable spring
bias 쩹; once the pressure setting is
reached, the piston is urged forward so
as to actuate a microswitch 쩺 and
make or break its contacts.
The pressure setting is selected by tur-
ning a graduated control knob 쩻.
Clockwise rotation increases the set-
ting pressure.
Pressure switches are designed to
operate in hydraulic systems with
hydraulic mineral oil or synthetic fluid
having similar lubricating characteri-
stics.
Max pressure = 650 bar
Assembly position / location Any position
Subplate surface finishing Roughness index flatness ratio 0,01/100 (ISO 1101)
Ambient temperature from -20°C to +70°C
Fluid Hydraulic oil as per DIN 51524 .... 535; for other fluids see section
쪧
Recommended viscosity 15 ÷ 100 mm
2
/s at 40°C (ISO VG 15 ÷ 100)
Fluid contamination class ISO 19/16, achieved with in line filters at 25 µ value and ß
25
≥ 75 (recommended)
Fluid temperature T ≤ 80°C; if T ≤ 60°C select /PE seals
2
MAIN CHARACTERISTICS OF PRESSURE SWITCHES TYPE MAP
햲 Servo-piston
햳 Spring
햴 Microswitch
햵 Control knob
햶 Body
햷 Switch actuator
햸 Control knob setscrew
햹 Electric connector
Threated connections for BMM and BFM adaptors, see section 쪭
BMM BFM
06 = G 1/4" 06 = G 1/4"
10 = G 3/8" 10 = G 3/8"
15 = G 1/2" 15 = G 1/2"
20 = G 3/4"
BMF 25 = G 1"
06 = G 1/4" 32 = G 1
1
/
4
"
Port to serve for BHM and BKM adaptors, see section 쪭
11 = port P 14 = port B
12 = port A und B 17 = port P and A
13 = port A 18 = portP and B
Options:
E = Common electric contact connected
to pin 1 (see section 쪩)
Synthetic fluids:
WG = water-glycol
PE = phosphate ester
MAP
Fixed differential
pressure switch
1
Pressure range:
40 = 5 ÷ 40 bar
80 = 7 ÷ 80 bar
160 = 10 ÷ 160 bar
320 = 30 ÷ 320 bar
630 = 50 ÷ 630 bar
Type of adaptor (if required), see section
쪬
and
쪭
/M = BMM – adaptor - male fittings
/MF = BMF – adaptor - female fittings
/F = BFM – adaptor - in line mounting
/H = BHM adaptor - modular mounting
ISO 4401 size 06
/K = BKM adaptor - modular mounting
ISO 4401 size 10
160-06
/WG
MODEL CODE
/M /E **
Series number
Max current [A]
- inductive load (Cos ϕ = 0,4) -
Max current [A]
- resistive load -
D250
3 MAIN CHARACTERISTICS AND WIRING OF INTERNAL MICROSWITCH
Insulating resistance ≥ 100 MΩ
Contact resistance = 15 mΩ
Electrical life-expectancy ≥ 1.000.000 switchings
Mechanical life-expectancy
≥ 10.000.000 switchings
7550,2
4 2 3 0,02
125 AC 250 AC 30 DC 250 DC
Supply voltage [V]
Resting position Pressure operated position
STD
/E
Table D250-0/Ewww.atos.com
Note: special version with gold-plated microswitch contact available on request