Proportional pressure reducing valves type DHRZE
direct operated, ISO 4401 size 06
TF042
DHRZE-A
3
way, direct operated pressure reducing
v
alves, size 06, with proportional solenoids
certified according to North American standard
cURus.
T
hey operate is association with electronic
d
rivers, see section
2
,
which supply the
p
roportional solenoids with proper current to
a
lign the pressure regulation to the reference
signal.
Technical characteristics
T
hey provide the pressure reduction on ports A,
o
r B or A and B, depending on the valve model.
T
he direct execution performs low internal
l
eakages, fast response and low hysteresis.
The solenoid coils are plastic encapsulated with
insulation class H and they are available with
different nominal resistances depending to the
voltage supply (12 V
DC or 24 VDC) and to the
e
lectronic driver type, see section
2
a
nd
3
T
ypical applications
Pressure reduction in low flow systems
P
ilot stage of pilot operated valves
Mounting surface: ISO 4401, size 06
M
ax flow: 24 l/min
Max pressure: 315 bar
Max regulated pressure: 25 bar
Proportional pressure
reducing valve size 06
A = open loop pressure control
Configuration:
010 = reduced pressure on port A (port B for option /B)
012 = reduced pressure on port A and B
1 MODEL CODE
Regulated pressure:
25 = reduced pressure range 3÷25 bar
DHRZE
/
/
--
A 010 25 **
*
Seals material,
see sect.
5
:
- =
NBR
PE = FKM
BT = HNBR
Series
number
DHRZE- A-012/25
A
B
V
alve body
Spool
Proportional solenoid
Electric connector (supplied with the valve)
B
leeding screw
y
x
c
v
b
T
able
TF042-1/E
Coil options
see section
3
and
4
:
- = standard coil for 24V
DC Atos drivers
6 = optional coil for 12V
DC Atos drivers
18 = optional coil for 24V
D
C
low current drivers
* *
Hydraulic option
B= reduced pressure on port B, solenoid side of port A
(only for valve configuration 010)
/
/
HYDRAULIC SYMBOLS
DHRZE-A-010/25 DHRZE-A-010/25/B DHRZE-A-012/25
2 ELECTRONIC DRIVERS
Drivers model E-MI-AC E-MI-AS-IR E-BM-AC E-BM-AS-PS E-BM-AES E-ME-AC
Type analog digital analog digital digital analog
Voltage supply (V
DC
)
12 24 12 24 12 24 12 24 24 24
Valve coil option /6 std /6 std /6 std /6 std std std
Format
DIN 43650
plug-in to solenoid
DIN 43700
UNDECAL
DIN-rail panel EUROCARD
Data sheet G010 G020 G025 G030 GS050 G035
4
M
AIN CHARACTERISTICS - based on mineral oil ISO VG 46 at 50 °C
24
45
1,5
3
2
Max regulated pressure (Q=1 l/min) [bar]
Min. regulated pressure
(Q=1 l/min) (1) [bar]
Max. pressure at port P [bar]
Max. pressure at port T
[bar]
Max. flow
[l/min]
Response time 0-100% step signal (2)
[ms]
(depending on installation)
Hysteresis [% of the max pressure]
Linearity [% of the max pressure]
Repeatability [% of the max pressure]
3
2
5
315
210
(1) Min pressure value to be increased of T line pressure
(2) Average response time value; the pressure variation in consequence of a modification of the reference input signal to the valve is affected
by the stiffness of the hydraulic circuit: greater is the stiffness of the circuit, faster is the dynamic response
Notes:
above performance data refer to valves coupled with Atos electronic drivers, see section
2
3
COIL OPTIONS
C
oil voltage
Option /6 optional coil to be used with Atos drivers with power supply 12 V
DC
O
ption /18 optional coil to be used with electronic drivers not supplied by Atos
5
SEALS AND HYDRAULIC FLUID - for other fluids not included in below table, consult our technical office
Seals, recommended fluid temperature
NBR seals (standard) = -20°C ÷ +60°C, with HFC hydraulic fluids = -20°C ÷ +50°C
FKM seals (/PE option) = -20°C ÷ +80°C
HNBR seals (/BT option) = -40°C ÷ +60°C, with HFC hydraulic fluids = -40°C ÷ +50°C
Recommended viscosity 20÷100 mm
2
/s - max allowed range 15 ÷ 380 mm
2
/s
Fluid contamination class
ISO 4406 class 20/18/15 NAS 1638 class 9, in line filters of 10 µm (β10 _>75 recommended)
Hydraulic fluid Suitable seals type Classification Ref. Standard
Mineral oils
NBR, FKM, HNBR HL, HLP, HLPD, HVLP, HVLPD DIN 51524
Flame resistant without water FKM HFDU, HFDR
ISO 12922
Flame resistant with water NBR, HNBR HFC
Assembly position / location Any position
S
ubplate surface finishing (RZME)
R
oughness index Ra 0,4 - flatness ratio 0,01/100 (ISO 1101)
M
TTFd valves according to EN ISO 13849
1
50 years, see technical table P007
Ambient temperature
S
tandard and /PE option = -20°C ÷ +70°C; /BT option = -40°C ÷ +60°C
S
torage temperature
Standard and /PE option = -20°C ÷ +80°C; /BT option = -40°C ÷ +70°C
C
oil code
Standard
s
tandard coil to be used
w
ith Atos drivers with power
s
upply 24V
DC
option /6
o
ptional coil to be used with
A
tos drivers with power
s
upply 12 V
DC
option /18
optional coil to be used with elec-
t
ronic drivers not supplied by
A
tos, with power supply 24 VDC
and max current limited to 1A
C
oil resistance R at 20°C
3 ÷ 3,3
2 ÷ 2,2
13 ÷ 13,4
Max. solenoid current 2,2 A 2,75 A 1,2 A
Max. power 30 Watt
P
rotection degree (CEI EN-60529)
I
P65
Duty factor Continuous rating (ED=100%)
Certification
c
URus North American Standard
DHRZE proportional valves are CE marked according to the applicable
Directives (e.g. Immunity/Emission EMC Directive and Low Voltage Directive).
Installation, wirings and start-up procedures must be performed according to
the general prescriptions shown in table F003 and in the installation notes
supplied with relevant components.
6
GENERAL NOTES
7
CONNECTIONS
Signal description
SUPPLY
SUPPLY
GND
PIN
1
2
3
SOLENOID POWER SUPPLY CONNECTOR
1
2
3
Reference signal [% of max]
[
A-T] [P-A]
[
B-T] [P-B]
Regulated pressure [bar]
Flow [l/min]
Pressure reduced [bar]
D
IAGRAMS based on mineral oil ISO VG 46 at 50°C
8
05/18
9 INSTALLATION DIMENSIONS FOR DHRZE [mm]
Mass: 1,9 kg
DHRZE-A-010
I
SO 4401: 2005
Mou
nting surface: 4401-03-02-0-05
Fastening bolts: 4 socket head screws M5x30 class 12.9
Tightening torque = 8 Nm
S
eals: 4 OR 108;
D
iameter of ports A, B, P, T: Ø 7,5 mm (max)
Mass: 2,6 kg
DHRZE-A-012
6977.5 10.5
22
157
45
==
47.5 28.5
81.5
DHRZE-A-010/B
69 77.510.5
22
21.5
51
157
69 77.577.5
224
screw for air bleeding