5 EX PROOF SOLENOID: ELECTRICAL CHARACTERISTICS
Seals, recommended fluid temperature
NBR seals (standard) = -20°C ÷ +60°C, with HFC hydraulic fluids = -20°C ÷ +50°C
FKM seals (/PE option) = -20°C ÷ +80°C
Recommended viscosity 15÷100 mm
2
/s - max allowed range 2.8 ÷ 500 mm
2
/s
Fluid contamination class
ISO 4406 class 21/19/16 NAS 1638 class 10, in line filters of 25 μm (β25 _> 75 recommended)
Hydraulic fluid Suitable seals type Classification Ref. Standard
Mineral oils
NBR, FKM HL, HLP, HLPD, HVLP, HVLPD DIN 51524
Flame resistant without water FKM HFDU, HFDR
ISO 12922
Flame resistant with water NBR HFC
6
SEALS AND HYDRAULIC FLUIDS -
for other fluids not included in below table, consult our technical office
Operating pressure
Ports P,A,B: 350 bar;
Port T 210 bar
Rated flow
See diagrams Q/Δp at section
13
Maximum flow
70 l/min, see operating limits at section
14
4
HYDRAULIC CHARACTERISTICS
Assembly position / location Any position
Subplate surface finishing to ISO 4401
Acceptable roughness index, Ra ≤0,8 recommended Ra 0,4 - flatness ratio 0,01/100
MTTFd values according to EN ISO 13849
150 years, for further details see technical table P007
Ambient temperature
Standard = -20°C ÷ +70°C /PE option = -20°C ÷ +70°C
Storage temperature range
Standard = -20°C ÷ +80°C /PE option = -20°C ÷ +80°C
Surface protection
Zinc coating with black passivation - salt spray test (EN ISO 9227) > 200h
Compliance
Explosion proof protection, see section
for /FI proximity sensor and section
for solenoid
-Flame proof enclosure “Ex d”
-Dust ignition protection by enclosure “Ex t”
RoHS Directive 2011/65/EU as last update by 2015/863/EU
REACH Regulation (EC) n°1907/2006
7 8
3
GENERAL CHARACTERISTICS
Supply voltage (1) [V] 8,2 VDC
Current consumption [mA] 3 mA (de-energized) 1 mA (energized)
Protection degree IP66/IP67 according to IEC 60529
Max pressure [bar] 350
Ambient temperature -25 ÷ +85 °C
7 PROXIMITY SENSOR: GENERAL CHARACTERISTICS AND CERTIFICATION DATA
SENSOR TYPE NJ1,5-18GM-N-D-V1
(1) For application in explosive environments, the inductive proximity sensor must be electrically supplied by means of a galvanic insulated
power amplifier (safety barrier) for intrinsically safe circuits, classified for Zone 1 and 2
Type examination certificate
• ATEX PTB 00 ATEX 2048 X
• IECEx IECEx PTB 11.0037X
• CCC 2020322315002255
• EAC TC RU C-DE.AA87.B.00394
• cULus UL-US-2019259-0 / UL-CA-2015551-0
Method of protection
• ATEX, EAC Ex ia IIC T6...T1 Ga; Ex ia IIC T6...T1 Gb; II 1 D Ex ia IIIC T200 135°C Da
• IECEx Ex ia IIC T6...T1 Ga; Ex ia IIC T6...T1 Gb; Ex ia I Mb; Ex ia IIIC T200 135°C Da
• CCC Ex ia IIC T1~T6 Ga; Ex ia IIC T1~T6 Gb; Ex ia IIC T1~T6 Gc; Ex iaD 20 T135; Ex ibD 21 T135
• cULus Class2 or LV/LC
(1) For alternating current supply a rectifier bridge is provided built-in the solenoid
For power supply frequency 60 Hz, the nominal supply voltage of solenoids 110AC and 230AC must be 115/60 and 240/60 respectively
Coil insulation
VAC 50/60 Hz ±10%
Voltage code (1)
V
DC ±10%
Duty factor
Power consumption at 20°C
Protection degree with relevant cable gland
22*104 DHA
22*104 DHA/M
22*104 DHA/UL
Valve type
12DC, 24DC, 28DC, 48DC, 110DC, 125DC, 220DC
12DC, 24DC, 110DC,
125DC, 220DC
12AC, 24AC, 110AC, 230AC
12AC, 24AC, 110AC, 230AC
8W
12W
class H
IP66/67 to DIN EN60529
raintight enclosure, UL approved
100%