Ex-proof solenoid valves
with spool position monitoring
on/off, direct, with inductive proximity sensor -
ATEX, IECEx, EAC, CCC or CULUS
Availability and price only on request
Table TEX130-2/E
TEX130
22*104 DHA-0631/2/GK/FI/NO 24DC
A
B
valve body
spool
ex-proof solenoid
ex-proof inductive proximity sensor
proximity sensor connector (supplied with the valve)
Special execution with
ex-proof proximity sensor
DHA = spool type - direct
1 MODEL CODE OF SPOOL TYPE ON-OFF DIRECTIONAL SOLENOID VALVES
--//
Valve size (ISO 4401)
0 = 06
Voltage Code:
see section
5
2
CONFIGURATION AND SPOOLS
Spools
Configurations 63 is available only for spool type 0/2, 1/2 and 2/2; Configurations 61, 67 and 71 are available only for spools 0, 1, 3 and 4
Electrical signal:
/NO = electric contact is open when the valve is
de-energized
/FI = inductive proximity sensor
22*104 DHA 0 63 1/2 GK FI * * 24DC /*
Seals material
- =
NBR
PE = FKM
Solenoid threaded connection for cable gland fitting:
GK = GK-1/2” - not for
CULUS (2)
M = M20x1,5 - not for
CULUS
NPT = 1/2” NPT
Configuration
, see section
:
2
Spool type
, see section
:
2
/
*
Certification type:
Multicertification
ATEX, IECEx, EAC, CCC:
- = omit for Group II 2G / II 2D (1)
M = Group I M2 (mining)
North American Certification:
UL =
CULUS
12
G
12
G
102
GG
7163
67/A63/A
0
1
34
61/A
02
G
10
G
61 67
02
G
10
G
0/2
1/2
2/2
0102
0102
0102
0102
0102
0102 0102
Options:
A = solenoid at side of port B
(for single solenoid valves)
O = horizontal cable entrance (1)
WP =
manual override protected
by metallic cap
(1) Not for multicertification M group I (mining) (2)
Approved only for the Italian market
22*104 DHA
On-off, spool type directional valves
equipped with ex-proof solenoids and
proximity sensor for the spool position
monitoring, certified for safe operation in
hazardous environments with potentially
explosive atmosphere.
Certifications:
Multicertification ATEX, IECEx, EAC, CCC
for gas group II 2G and dust category II 2D
Certification IECEx for gas group I M2 (mining)
cULUS North American certification for gas
Note: the valve is not certified in conformity
to the Machine Directive 2006/42/CE
Size: 06 - ISO 4401
Max flow: 70 l/min
Max pressure: 350 bar
75
5 EX PROOF SOLENOID: ELECTRICAL CHARACTERISTICS
Seals, recommended fluid temperature
NBR seals (standard) = -20°C ÷ +60°C, with HFC hydraulic fluids = -20°C ÷ +50°C
FKM seals (/PE option) = -20°C ÷ +80°C
Recommended viscosity 15÷100 mm
2
/s - max allowed range 2.8 ÷ 500 mm
2
/s
Fluid contamination class
ISO 4406 class 21/19/16 NAS 1638 class 10, in line filters of 25 μm (β25 _> 75 recommended)
Hydraulic fluid Suitable seals type Classification Ref. Standard
Mineral oils
NBR, FKM HL, HLP, HLPD, HVLP, HVLPD DIN 51524
Flame resistant without water FKM HFDU, HFDR
ISO 12922
Flame resistant with water NBR HFC
6
SEALS AND HYDRAULIC FLUIDS -
for other fluids not included in below table, consult our technical office
Operating pressure
Ports P,A,B: 350 bar;
Port T 210 bar
Rated flow
See diagrams Q/Δp at section
13
Maximum flow
70 l/min, see operating limits at section
14
4
HYDRAULIC CHARACTERISTICS
Assembly position / location Any position
Subplate surface finishing to ISO 4401
Acceptable roughness index, Ra 0,8 recommended Ra 0,4 - flatness ratio 0,01/100
MTTFd values according to EN ISO 13849
150 years, for further details see technical table P007
Ambient temperature
Standard = -20°C ÷ +70°C /PE option = -20°C ÷ +70°C
Storage temperature range
Standard = -20°C ÷ +80°C /PE option = -20°C ÷ +80°C
Surface protection
Zinc coating with black passivation - salt spray test (EN ISO 9227) > 200h
Compliance
Explosion proof protection, see section
for /FI proximity sensor and section
for solenoid
-Flame proof enclosure “Ex d”
-Dust ignition protection by enclosure “Ex t”
RoHS Directive 2011/65/EU as last update by 2015/863/EU
REACH Regulation (EC) n°1907/2006
7 8
3
GENERAL CHARACTERISTICS
Supply voltage (1) [V] 8,2 VDC
Current consumption [mA] 3 mA (de-energized) 1 mA (energized)
Protection degree IP66/IP67 according to IEC 60529
Max pressure [bar] 350
Ambient temperature -25 ÷ +85 °C
7 PROXIMITY SENSOR: GENERAL CHARACTERISTICS AND CERTIFICATION DATA
SENSOR TYPE NJ1,5-18GM-N-D-V1
(1) For application in explosive environments, the inductive proximity sensor must be electrically supplied by means of a galvanic insulated
power amplifier (safety barrier) for intrinsically safe circuits, classified for Zone 1 and 2
Type examination certificate
• ATEX PTB 00 ATEX 2048 X
• IECEx IECEx PTB 11.0037X
• CCC 2020322315002255
• EAC TC RU C-DE.AA87.B.00394
• cULus UL-US-2019259-0 / UL-CA-2015551-0
Method of protection
• ATEX, EAC Ex ia IIC T6...T1 Ga; Ex ia IIC T6...T1 Gb; II 1 D Ex ia IIIC T200 135°C Da
• IECEx Ex ia IIC T6...T1 Ga; Ex ia IIC T6...T1 Gb; Ex ia I Mb; Ex ia IIIC T200 135°C Da
• CCC Ex ia IIC T1~T6 Ga; Ex ia IIC T1~T6 Gb; Ex ia IIC T1~T6 Gc; Ex iaD 20 T135; Ex ibD 21 T135
• cULus Class2 or LV/LC
(1) For alternating current supply a rectifier bridge is provided built-in the solenoid
For power supply frequency 60 Hz, the nominal supply voltage of solenoids 110AC and 230AC must be 115/60 and 240/60 respectively
Coil insulation
VAC 50/60 Hz ±10%
Voltage code (1)
V
DC ±10%
Duty factor
Power consumption at 20°C
Protection degree with relevant cable gland
22*104 DHA
22*104 DHA/M
22*104 DHA/UL
Valve type
12DC, 24DC, 28DC, 48DC, 110DC, 125DC, 220DC
12DC, 24DC, 110DC,
125DC, 220DC
12AC, 24AC, 110AC, 230AC
12AC, 24AC, 110AC, 230AC
8W
12W
class H
IP66/67 to DIN EN60529
raintight enclosure, UL approved
100%
8 SOLENOID CERTIFICATION DATA
TEX130
Type examination certificate (1)
Method of protection
Cable entrance: threaded connection
vertical (standard) or horizontal (option /O)
22*104 DHA
22*104 DHA/M
22*104 DHA/UL
T6
85 °C
-40 ÷ +45 °C
ATEX: CESI 02 ATEX 014
IECEx: IECEx CES 10.0010x
EAC: RU C - IT.AЖ38.B.00425/21
PESO: P468212/2
CCC: 2020322307003240
ATEX: CESI 03 ATEX 057x
IECEx: IECEx CES 12.0007x
EAC: TC RU C-IT. 08.B.01784
CCC: ***YY***
20170324 - E366100
OA
OA/M OA/EC
Multicertification Group II Multicertification Group I North American
CULUS
-
150 °C
-20 ÷ +70 °C
T4
135 °C
-40 ÷ +70 °C
T6
-40 ÷ +55 °C
T5
-40 ÷ +70 °C
Valve type
Solenoid certified code
UL 1203 and UL429,
CSA 22.2 n°30-1986
CSA 22.2 n°139-13
Temperature class
Surface temperature
Ambient temperature
(2)
85 °C 100 °C
ATEX, IECEx, EAC, PESO, CCC
CULUS
Certifications
ATEX, IECEx
• ATEX
Ex I M2 Ex db I Mb
• IECEx
Ex db I Mb
• ATEX
Ex II 2G Ex db IIC T6/T4/T3 Gb
Ex II 2D Ex tb IIIC T85°C/T200°C Db
• IECEx
Ex db IIC T6/T4/T3 Gb
Ex tb IIIC T85°C/T200°C Db
• EAC
1Ex d IIC T6/T4/T3 Gb X
Ex tb IIIC T85°C/T200°C Db X
• PESO
Ex db IIC T6/T4/T3 Gb
• CCC
Ex d IIC T6/T4/T3 Gb
Ex tD A21 IP66/IP67
T85°C/T135°C/T200°C
• UL 1203
Class I, Div.I, Groups C & D
Class I, Zone I, Groups IIA & IIB
GK = GK-1/2”
M = M20x1,5
NPT = 1/2” NPT
1/2” NPT ANSI/ASME B46.1
(1) The type examinator certificates can be downloaded from www.atos.com
(2) The solenoids Group II and CULUS are certified for minimum ambient temperature -40°C
WARNING: service work performed on the valve by the end users or not qualified personnel invalidates the certification
Applicable standards
EN 60079-0
EN 60079-1
EN 60079-31
IEC 60079-0
IEC 60079-1
IEC 60079-31
1 = Coil
2 = GND
3 = Coil
PCB 3 poles terminal board
suitable for wires cross sections
up to 2,5 mm
2
(max AWG14)
9
EX PROOF SOLENOIDS WIRING
Standard version
Option /O
cover with threaded connection for vertical cable gland fitting
cover with threaded connection for horizontal cable gland fitting
terminal board for cables wiring
standard manual override
screw terminal for additional equipotential grounding
Multicertification
C
UL
US
certification
Standard version
Option /O
cover with threaded connection for vertical cable gland fitting
cover with threaded connection for horizontal cable gland fitting
terminal board for cables wiring
standard manual override
1 = Coil +
2 = GND
3 = Coil -
alternative GND screw terminal
connected to solenoid housing
Pay attention to coil polarity
PCB 3 poles terminal board suggest-
ed cable section up to 1,5 mm
2
(max
AWG16), see section
note 1
10
3
n°4 M4
locking torque 4Nm
3
n°4 M4
locking torque 4Nm
11
CABLE GLANDS only for Multicertification
Cable glands with threaded connections GK-1/2”, 1/2”NPT or M20x1,5 for standard or armoured cables have to be ordered separately,
see tech. table KX800
Note: a Loctite sealant type 545, should be used on the cable gland entry threads
Max ambient temperature [°C]
Temperature class
Group I Group II
Max surface temperature [°C]
Group I Group II
Min cable temperature
45 °C not prescribed
70 °C 90 °C
Max ambient temperature [°C] Temperature class Max surface temperature [°C] Min cable temperature
55 °C T6 85 °C 100 °C
70 °C T5 100 °C 100 °C
CULUS certification
Multicertification
10
CABLE SPECIFICATION AND TEMPERATURE - Power supply and grounding cables have to comply with following characteristics:
10.1 Cable temperature
The cable must be suitable for the working temperature as specified in the “safety instructions” delivered with the first supply of the products.
Power supply: section of coil connection wires = 2,5 mm
2
Grounding: section of internal ground wire = 2,5 mm
2
section of external ground wire = 4 mm
2
Multicertification Group I and Group II
cULus certification:
• Suitable for use in Class I Division 1, Gas Groups C
• Armored Marine Shipboard Cable which meets UL 1309
• Tinned Stranded Copper Conductors
• Bronze braided armor
• Overall impervious sheath over the armor
Any Listed (UBVZ/ UBVZ7) Marine Shipboard Cable rated 300 V min, 15A min. 3C 2,5 mm
2
(14 AWG) having a suitable service temperature
range of at least -25°C to +110°C
Note 1: For Class I wiring the 3C 1,5 mm
2
AWG 16 cable size is admitted only if a fuse lower than 10 A is connected to the load side of the
solenoid wiring.
85 °C
135 °C
150 °C
150 °C
T6
T4
-
-
12 PROXIMITY SENSOR CONNECTION
40
~ 30
+ = Brown
- = White
cable length = 3m
Pin 1
Pin 2
Pin 3 = Blu - do not connect
Pin 4 = Black - do not connect
The diagram have been obtained with warm
solenoids and power supply at lowest value
(Vnom-10%).
The curves refer to application with symmetrical
flow through the valve (i.e. PA and BT).
In case of asymmetric flow the operating limits
must be reduced.
13
Q/Δp DIAGRAMS (based on mineral oil ISO VG 46 at 50°C)
Flow rate [l/min]
FE
D
C
B
A
Flow rate [l/min]
Inlet pressure [bar]
C
A
B
14
OPERATING LIMITS (based on mineral oil ISO VG 46 at 50°C)
0, 1
0/2, 1/2, 3
2/2, 4
A
B
C
Spool type
diagram
Flow direction
Spool type
PA PB AT BT PT
0 A A B B C
1 C B B B
3
C C A A
4 E E F B D
1/2, 0/2 C C C C
2/2 E E
24
20
16
12
8
4
0
400
320
240
160
80
0
15 30 45 60 75
Valve pressure drop Δp [bar]
15 30 45 60 75
15
FASTENING BOLTS AND SEALS
Fastening bolts:
4 socket head screws M5x50 class 12.9
Tightening torque = 8 Nm
Seals:
4 OR 108
Diameter of ports A, B, P, T: Ø 7,5 mm (max)
TEX130
07/23
16 INSTALLATION DIMENSIONS
17
RELATED DOCUMENTATION
X010 Basics for electrohydraulics in hazardous environments
X020 Summary of Atos ex-proof components certified to ATEX,
IECEx, EAC, CCC, PESO
X030 Summary of Atos ex-proof components certified to cULus
EX900 Operating and maintenance information for ex-
proof on-off valves
KX800 Cable glands for ex-proof valves
P005 Mounting surfaces for electrohydraulic valves
22*104 DHA-06* 22*104 DHA-06*/A
22*104 DHA-07*
option /O option /WP option /OWP
ISO 4401: 2005 (see table P005)
Mounting surface:
4401-03-02-0-05
P = PRESSURE PORT
A, B = USE PORT
T = TANK PORT
ø5.5
40.5
30.2
21.5
12.7
31
25.9
15.5
5.1
0.75
31.75
Valve’s bottom view
Mass [kg]
22*104 DHA-06 3,15
22*104 DHA-07 5,3
Option /O +0,35
Option /WP +0,25
50
25 25
87
98.5
for UL
100
187.5
30 7780.5
7
187.5
3077 80.5
7
287
30 6680.5
7
30 80.5
7
80.57
68.5
18.5
30 for UL
68.5
115.5
47
87
98.5
for UL
68.5
115.5
47
80.5
80.526.5
26.5
Proximity sensor connector
(cable length 3m) supplied
with the valve