www.atos.com
On-off explosion-proof solenoid valves with MA certification
ISO 4401 size 06 and 10 (direct), 16 and 25 (pilot operated)
Table SE121-0/E
SE121
SDKA/MA-16
SDHA/MA-07
valve body
ex-proof solenoid
horizontal cable gland
1 EXPLOSION PROOF SOLENOIDS: MAIN DATA
Power consumption 16,5 W (SDHA, SDPHA) 18W (SDKA)
Method of protection Ex d
Temperature class T4
Surface temperature 135 °C
Ambient temperature -20 ÷ +40 °C
Protection degree IP 65
Duty factor 100%
Mechanical construction Flame proof housing classified Ex d
Cable entrance and electrical wiring
Horizontal cable gland, internal terminal board for cable connection, see section
MA Certification Ex d = Equipment for explosive atmosphere, flame proof housing
I = Gas group (Methane)
Mb = Equipment protection, high level protection for explosive atmospheres
Voltage code VDC ±10% 12DC, 24DC, 110DC
SOLENOID TYPE ON/OFF
On/off direct and pilot operated directional
valves equipped with explosion-proof
solenoids certified according to MA Chinese
mining certification, protection mode:
Ex d I Mb for surface, tunnel or mine plants
The solenoids are provided with cable glands
(horizontally oriented) for cable entrance and
internal terminal board for power supply coils
connections.
The solenoid case classified Ex d is designed
to contain the possible explosion which could
be caused by the presence of the gas mixture
inside the housing, thus avoiding dangerous
propagation in the external environment.
They are also designed to limit the external
temperature according to the certified class to
avoid the self ignition of the explosive mixture
present in the environment.
Assembly position / location Any position
Subplate surface finishing Roughness index Ra 0,4 - flatness ratio 0,01/100 (ISO 1101)
Fluid Hydraulic oil as per DIN 51524 .... 535
Recommended viscosity 15 ÷ 100 mm
2
/s at 40°C (ISO VG 15 ÷ 100)
Fluid contamination class ISO 4406 class 21/19/16 NAS 1638 class 10, in line filters of 25 μm (β25 _>75 recommended)
Fluid temperature -20°C +60°C (standard seals) -20°C +80°C (/PE seals)
Flow direction As shown in the symbols of table
and
Operating pressure
2 MAIN CHARACTERISTICS OF EX-PROOF VALVES
P, A, B = 350 bar
T = 210 bar
P, A, B = 315 bar
T = 210 bar
P, A, B, X = 350 bar
T = 250 bar for external drain (standard)
T = 210 bar with internal drain (option /D)
Ports Y = 0 bar - Minimum pilot pressure for correct operation is 8 bar
SDHA
SDKA
SDPHA
80 l/min see section 8, operating limits
120 l/min see section 8, operating limits
SDPHA-2: 300 l/min; SDPHA-4: 700 l/min, see section
, operating limits
SDHA
SDKA
SDPHA
Maximum flow
4
CONFIGURATION OF SDHA VALVES
SDPHA = spool type - piloted
5 MODEL CODE OF PILOTED SOLENOID VALVES TYPE SDPHA
MA = Ex-proof Ma Chinese mining certification
Valve configuration, see section
Spool type, see section
Seals material:
omit for NBR (mineral oil
& water glycol)
PE = FPM
Series number
SDPHA 2MA/– 63
1/2
24DC **
/*
Valve size (ISO 4401)
2 = 16 4 = 25
Voltage code - see section
-
A
(1) Not for group I, Atex (mining)
Options:
A = solenoid at side of port B (for single solenoid valves)
/D =Internal drain
/E =External pilot pressure
/H =Adjustable chokes (meter-out to the pilot chambers of the main valve)
/S = Main spool stroke adjustment
2
1
2
1
02
1
0
1
71
63
61
75
67/A
63/A
61/A
67
0
8
12
3
91
58
4
19
5
93
6
39
7
02
02
2
1
0/2
1/2
2/2
1/2
0/2
0102
0102
0102
0102
0102
0102
Configurations Spools Configurations Spools
SDHA = spool type - direct, size 06
SDKA = spool type - direct, size 10
3 MODEL CODE OF DIRECT SOLENOID VALVES TYPE SDHA, SDKA
Valve configuration, see section
0 = size 06 for SDHA
1 = size 10 for SDKA
MA = Ex-proof Ma Chinese mining certification
Spool type, see section
Seals material:
omit for NBR (mineral oil & water glycol)
PE = FPM
Series number
SDHA /MA 630 1/2 24DC **
/*
Voltage code - see section
-
A
Options:
A = solenoid at side of port B (for single solenoid valves)
Spools type 0 and 3 are also available as 0/1 and 3/1 with restricted oil passages in central
position, from user ports to tank.
Spools type 1, 4, 5, 6 and 7 are also available as 1/1, 4/8, 5/1, 6/1
and
7/1 that are properly sha-
ped to reduce water-hammer shocks during the switching.
12
12
12
102
10
12
02
02
10
71
63
61
75
67/A
63/A
61/A
67
6
CONFIGURATIONS and SPOOLS
012
3
91
4
19
5
93
6
39
7
0/2
1/2
2/2
0102
0102
0102
0102
0102
70
Configurations Spools Configurations Spools
Spools 0 and 3 are also available as 0/1
and 3/1 with restricted oil passages in
central position, from user ports to tank.
S
pools 1, 4, 5 and 58 are also available as
1/1, 4/8, 5/1 and 58/1. They are properly
shaped to reduce water-hammer shocks
during the swiching.
SE121
7
Q/ΔP DIAGRAMS based on mineral oil ISO VG 46 at 50°C
Flow direction
Spool type
PAPBATBTPT
SDHA
Valve pressure drop Δp [bar]
Flow rate [l/min]
GF
E
D
C
B
A
0, 0/1 A A C C D
1, 1/1 D C C C
3, 3/1
DDAA
4, 4/8, 5, 5/1, 58, 58/1
FFGCE
19, 91, 93, 39
1/2, 0/2 D D D D
6, 7 D D D D
8AAEE
2DD
2/2 F F
0, 0/1, 0/2, 2/2 A A B B
1, 1/1, 1/3, 6, 8 A A D C
3, 3/1, 7 A A C D
4 BBBBF
5ABCCG
1/2 B C C B
19 A D C H
Flow direction
Spool type
PAPBATBTPTBA
SDKA
SDKA
Valve pressure drop Δp [bar]
Flow rate [l/min]
G
F
E
D
C
B
A
H
Valve pressure drop Δp [bar]
Flow [l/min]
SDPHA-2
A
B
C
D
E
F
G
H
I
Valve pressure drop Δp [bar]
Flow [l/min]
SDPHA-4
A
B
C
D
E
F
GHIL
Spool
type
Flow
direction
Spool
type
Flow
direction
PAPBATBTPT
0/2, 1, 3, 6, 7, 8 A A D A -
1/1, 1/2, 7/1 B B D E -
0AADEC
0/1 A A D - -
2AA---
2/2 B B - - -
3/1 A A D D -
4CCHIF
4/8 C C G I F
5ABFHG
5/1 A B D F -
6/1 B B C E -
19 C - - G -
39 C - - H -
91 C C E - -
93 - C D - -
SDPHA-2
PAPBATBTPT
1BBBD-
1/1 D E E F -
1/2 E D B C -
0DCDEF
0/1, 3/1, 5/1, 6, 7 D D D F -
0/2 D D D E -
2BB---
2/2 E D - - -
3BBDF-
4CCHLL
5ADDDH
6/1 D E D F -
7/1 D E F F -
8DDEF-
19 F - - E -
39 G F - F -
91 F F D
93 - G D - -
SDPHA-4
SDHA
8
OPERATING LIMITS For a correct valve operation do not exceed the max recommended flow rates (l/min) shown in the below tables
Spool
70 140 210 350
0, 1, 3, 6, 7, 8 300 300 300 250
2, 4, 4/8 300 300 240 140
5 260 220 180 100
0/1, 0/2, 1/2 300 250 210 180
16, 17, 56, *9, 9*
300 300 270 200
Inlet pressure [bar]
Flow rate [l/min]
Spool
70 140 210 350
1, 6, 7, 8 700 700 700 600
2, 4, 4/8 500 500 450 400
5, 0/1, 0/2, 1/2 600 520 400 300
0, 3 700 700 600 540
16, 17, 58, *9, 9*
500 500 500 450
Inlet pressure [bar]
SDPHA-2
SDPHA-4
Flow rate [l/min]
Inlet pressure [bar]
SDHA
D
A
B
C
Inlet pressure [bar]
Flow rate [l/min]
SDKA
VY S M
T
SDHA
A = Spools 0, 0/1, 1, 1/2, 3, 8
B = Spools 0/2, 1/1, 6, 7
C = Spools 3/1, 4, 4/8, 5, 5/1, 19, 39, 58,
58/1, 09, 90, 91, 93, 94
D = Spools 2, 2/2
SDKA
M = Spools 0, 0/1, 1, 1/1, 3, 3/1, 1/2, 0/2, 8
S = Spools 1/3, 6, 7
Y = Spools 4, 5
V = Spools 2/2
T = Spools 19
CH.3
CH.7
9 SOLENOID WIRING
cable entrance = ø 10,5 mm
terminal board for power supply coil connection
screw terminal for ground connection
view from X
X
Flow rate [l/min]
10 INSTALLATION DIMENSIONS FOR SDHA AND SDKA
ISO 4401: 2005
Mounting surface:
4401-03-02-0-05
Fastening bolts: 4 socket head screws:
M5x30 class 12.9
Tightening torque = 8 Nm
Seals: 4 OR 108
Ports P,A,B,T: Ø = 7.5 mm (max)
P = PRESSURE PORT
A, B = USE PORT
T = TANK PORT
ISO 4401: 2005
Mounting surface according to 4401-05-05-0-05
(without X port, Y port optional)
Fastening bolts:
4 socket head screws M6x40 class 12.9
Tightening torque = 15 Nm
Seals: 5 OR 2050 and 1 OR 108
Ports P,A,B,T: Ø = 11.5 mm (max)
Ports Y: Ø = 5 mm
P = PRESSURE PORT
A, B = USE PORT
T = TANK PORT
SDKA
SDHA
SDHA-06
SDHA-07 (dotted line)
SDKA-16
SDKA-07 (dotted line)
Mass of basic versions:
SDHA-06: 3,2 kg
SDHA-07: 4,9 kg
manual override
horizontal cable gland, cable entrance = ø 10,5 mm
screw terminal for additional equipotential grounding
Mass of basic versions:
SDKA-16: 5,7 kg
SDKA-17: 8,7 kg
manual override
horizontal cable gland, cable entrance = ø 10,5 mm
screw terminal for additional equipotential grounding
SE121
11 INSTALLATION DIMENSIONS FOR SDPHA
ISO 4401: 2005
Mounting surface:
4401-07-07-0-05
Mass of basic versions
SDPHA-26: 10,8 kg
SDPHA-27: 12,5 kg
Fastening bolts:
4 socket head screws M10x50 class 12.9
Tightening torque = 70 Nm
2 socket head screws M6x45 class 12.9
Tightening torque = 15 Nm
Diameter of ports A, B, P, T: Ø = 20 mm;
Diameter of ports X, Y: Ø = 7 mm;
Seals: 4 OR 130, 2 OR 2043
P = PRESSURE PORT
A, B = USE PORT
T = TANK PORT
X = EXTERNAL OIL
PILOT PORT
Y = DRAIN PORT
View from X
max
ISO 4401: 2005
Mounting surface: 4401-08-08-0-05 (see table P005)
Fastening bolts:
6 socket head screws M12x60 class 12.9
Tightening torque = 125 Nm
Seals: 4 OR 4112; 2 OR 3056
Diameter of ports A, B, P, T: Ø = 24 mm;
Diameter of ports X, Y: Ø = 7 mm;
Mass of basic versions:
SDPHA-46: 19,4 kg
SDPHA-47: 21,9 kg
06/13
manual override
horizontal cable gland, cable entrance = ø 10,5 mm
screw terminal for additional equipotential grounding
SDPHA-2
SDPHA-26
SDPHA-27 (dotted line)
SDPHA-46
SDPHA-47 (dotted line)
manual override
horizontal cable gland, cable entrance = ø 10,5 mm
screw terminal for additional equipotential grounding
SDPHA-4
P = PRESSURE PORT
A, B = USE PORT
T = TANK PORT
X = EXTERNAL OIL PILOT PORT
Y = DRAIN PORT