For other available connectors, see tab. K500
5
ELECTRIC CONNECTORS ACCORDING TO DIN 43650 - the connectors must be ordered separately
Code of
connector
Function
669 With built-in rectifier bridge for supplying DC coils by alternating current (AC 110V and 230V - Imax 1A).
As 666 connector IP-65 but with built-in signal led, suitable for direct connection to electric supply source.
666 Connector IP-65, suitable for direct connection to electric supply source
667
Mineral oils
Hydraulic fluid
NBR, FKM, HNBR
FKM
NBR, HNBR
DIN 51524
ISO 12922
HL, HLP, HLPD, HVLP, HVLPD
HFDU, HFDR
HFC
Suitable seals type
Classification Ref. Standard
Flame resistant without water
Flame resistant with water
4
SEALS AND HYDRAULIC FLUID - for other fluids not included in below table, consult our technical office
Seals, recommended fluid temperature NBR seals (standard) = -20°C ÷ +60°C, with HFC hydraulic fluids = -20°C ÷ +50°C
FKM seals (/PE option) = -20°C ÷ +80°C
Recommended viscosity 15÷100 mm
2
/s - max allowed range 2,8 ÷ 500 mm
2
/s
Fluid contamination class ISO 4406 class 21/19/16 NAS 1638 class 10, in line filters of 25 mm (b25 _>75 recommended)
3
.1 Coils characteristics
(only for LIDASH)
Insulation class
P
ilot valve E
,
E
P: :
H
(180°C) for DC coils F (155°C) for AC coils
P
ilot valve I:
H (180°C) for DC or AC coils
D
ue to the occuring surface temperatures of the solenoid coils, the European standards EN ISO
1
3732-1
a
nd EN ISO 4413 must be taken into account
Protection degree to DIN EN 60529 IP 65 (with connectors 666, 667, 669 correctly assembled)
Relative duty factor 100%
Supply voltage and frequency See electric feature
Supply voltage tolerance ± 10%
Certification
CURUS North American Standard
Assembly position / location Any position
Subplate surface finishing Roughness index Ra 0,4 - flatness ratio 0,01/100 (ISO 1101)
Ambient temperature Standard execution = -30°C ÷ +70°C; /PE option = -20°C ÷ +70°C; /BT option = -40°C ÷ +70°C
Flow direction B A (preferred) or A B
Piloting LIDAS Pressure to X = close Pressure to Y = open
LIDASH De-energized = close Energized = open
3
M
AIN CHARACTERISTICS, SEALS AND HYDRAULIC FLUIDS
Poppet characteristics
AA [
cm
2
]
A
B (% of AA)
A
BP (% of AA)
A
A
P
(% of AA)
AA /
(A
A +
A
B)
poppet ratio
A
AP / (AA + AB) piloting ratio
240
450
1400
7
00
2100
S
i
ze
Ma
x
i
m
um
f
l
ow
a
t
D
p
=
5
b
a
r
[
l
/
m
i
n
]
16
2
5 32 40 50
3
1
2
,27
0
67,5
167,5
5
8,6
107,0
2
65,6
0
63,8
1
63,8
4
1,7
90,5
2
32,2
0
56,3
1
56,3
5
1,5
85,2
2
36,7
0
56,3
1
56,3
5
6,3
87,9
2
44,1
0
69
1
69
4
1,7
97,8
2
39,2
33, 43
1
,43
31
4
,91
33, 43
3
,46
1 for poppet 31 0,6 for poppet 33, 43
1,6 for poppet 31 1,6 for poppet 33, 43
31
8
,04
33, 43
5
,30
31
1
2,56
33, 43
8
,04
3
1
19,63
33, 43
1
3,85
2
00
3
60
1100
5
50
1
800
Poppet 31
Poppet 33
Poppet 43
2
20
4
00
1300
6
00
2
000
P
oppet type
P
orts A, B, X, Z
1,
Z
2:
350 bar Port Y: 120 bar
P
orts A, B, X, Z
1,
Z
2:
350 bar Port Y: 210 bar for DC version; 160 bar for AC version
Ports A, B, X, Z1, Z2: 420 bar Port Y: 210 bar for DC version; 160 bar for AC version
O
perating
p
ressure
P
ilot valve
I
Pilot valve E
P
ilot valve
EP
Ports A, B, X, Z1, Z2, Y: 420 bar
LIDAS
L
IDASH