Safety cartridge valves with poppet position monitoring
ISO standard, on-off, poppet type, conforming to Machine Directive 2006/42/EC - certified by
T
able
EY120-1/E
S
afety cartridge valves with poppet
p
osition monitoring, CE marked and
c
ertified by TÜV, in accordance with
safety requirements of Machine Directive
2006/42/EC.
LIFI: intermediate safety element with FI
inductive proximity sensor, to be coupled
with functional covers
L
IDA: safety valve with integral cover
d
esign and with FV inductive position
s
witch, available with optional solenoid
p
ilot valve (LIDAH)
L
IDAS: active pilot operated safety valve
with FV inductive position switch,
available with optional solenoid pilot valve
(LIDASH), see section for sensors
technical characteristics.
These valves are normally used to cut off the
hydraulic power line in case of emergency
c
ondition, thus avoiding dangerous
m
ovements of the machines actuators.
Certification
The TÜV certificate can be downloaded
from www.atos.com, catalog
on line,
t
echnical information section.
M
ounting surface & cavity:
ISO 7368 size 16 to 50
Max flow: up to 2000 l/min
Max pressure: 420 bar
11
www.atos.com
EY120
1
RANGE OF VALVE’S MODELS
LIDA-3243*/FVLIFI-3242*/NC
Valve
code
Size Description
DC solenoids AC solenoids
Sensor type
/FI /FV /FI /FV
LIFI
16÷50
intermediate elements with cartridge, to be coupled with a functional cover
••
LIDA(H)
16÷50 cartridges valve
••
LIDAS(H)
16÷50 active cartridges valve
••
LIDAS-3243*/FV
Size ISO 7368
16; 25; 32; 40; 50
Other dimensions available on request
Poppet position monitor:
I = inductive proximity switch
Type of poppet, see sect. for Q/Dp diagrams
42 = with damping nose, area ratio 1:1,1
43 = with damping nose, area ratio 1:5
Note: in LIFI safety valves the cartridge and the intermediate
element with poppet position sensor cannot be separated
Spring cracking pressure:
1 = 0,3 bar for poppet 42; 0,6 bar for poppet 43
2 = 1,5 bar for poppet 42
3 = 3 bar for all poppets
6 = 5,5 bar for all poppets
2
Series number
Intermediate saferty element and
cartridge according to ISO 7368
/
N
C
=
c
l
o
s
e
d
c
o
n
t
a
c
t
w
i
t
h
p
o
p
p
e
t
i
n
r
e
s
t
i
n
g
p
o
s
i
t
i
o
n
MODEL CODE OF LIFI INTERMEDIATE SAFETY ELEMENT - to be coupled with covers in section
Seals material:
omit for NBR (mineral
oil & water glycol)
PE = FKM
LIF I 25 42 1 NC ** *
//-
Inductive proximity sensor FI
I
nductive position switch FV
S
ensor electric connector (supplied with the valve)
3
G
Hydraulic symbols of LIFI
2.1
A
B
X Z1 Z2 Y
Notes: FI = inductive proximity sensor, type NO (normally open or NC (normally closed)
FV = inductive position switch providing both NO and NC contacts to be wired on the electric connector
See section for sensor’s characteristics
13
H
YDRAULIC SYMBOLS OF FUNCTIONAL COVERS
t
he following symbols show the functional covers coupled with intermediate safety element type LIFI
C
over type, see section 3.1
f
or hydraulic configuration:
A
= direct pilot
B = with shuttle valve for pilot
selection;
E
W* = with solenoid valve for pilot
s
election
B
H** = as EW* but with shuttle valve
for pilot selection;
F
= prearranged for coupling with LIFI cover
(
1) Max pressure is limited to 350 bar for pilot solenoid valve -I (DHI)
For valve type LIDB, LIDEW (in the configuration with external pilot line) Atos can supply leak free poppet type directional pilot valves type
D
LEH-3*. Consult our technical office for detailed information.
Type of pilot solenoid valve only for LIDBH** and LIDEW*:
I
= DHI for AC and DC supply - Pmax 350 bar
E = DHEP for AC and DC supply, high performances - Pmax 420 bar
C
over according to
ISO 7368
O
ptional different
s
etting of calibrated
p
lugs in the pilot
c
hannels (see tech.
tables H030, H040)
S
i
z
e
I
S
O
7368
1
=
16;
2
=
25;
3
=
32;
4
=
40;
5=
50;
O
nly for LIDEW* and LIDBH**:
X
= without connector, to be order separately see section
1
1
Voltage code only for LIDEW* and LIDBH**:
s
ee section
10
S
eries number
E
= with external attachment X (1/4” GAS) and underneath
p
ort X plugged
S
eals material:
omit for NBR (mineral oil &
w
ater glycol)
PE = FKM
LID A 2 E F I X 24DC ** * *
// /- -
3
MODEL CODE OF FUNCTIONAL COVERS TO BE COUPLED WITH LIFI SAFETY VALVES
3
.1
G G G G
G
G
G
G
G
G
G
G
LIDEW1P-* LIDEW2P-* LIDEW4P-*
LIDEW5P-* LIDEW6P-*
LIDEWP-*
LIDBP-*
LIDBH1AP-* LIDBH1CP-* LIDBH2AP-* LIDBH2CP-*
LIDAP
A
B
X Z1 Z2 Y
P
ABT
Pp
Z
1
Dr
Z
2
A
B
X Z1 Z2 Y
Pp
Z
1
Dr
Z
2
A
B
X Z1 Z2 Y
Pp
Z
1
Dr
Z
2
A
B
X Z1 Z2 Y
Pp
Z
1
Dr
Z
2
A
B
X Z1 Z2 Y
Pp
Z1
Dr
Z2
A
B
X Z1 Z2 Y
Pp
Z1
Dr
Z2
A
B
X Z1 Z2 Y
Pp
Z1
Dr
Z2
A
B
X Z1 Z2 Y
Pp
Z1
Dr
Z2
A
B
X Z1 Z2 Y
Pp
Z1
Dr
Z2
A
B
X Z1 Z2 Y
Pp
Z1
Dr
Z2
A
B
X Z1 Z2 Y
Pp
Z1
Dr
Z2
A
B
X Z1 Z2 Y
Pp
Z1
Dr
Z2
P
H
igh pressure execution, Pmax 420 bar (1)
G
G
L
IDAH-**43/FVLIDA-**43/FV
H
Y
D
R
A
U
LI
C
S
Y
M
B
OLS
OF
LI
D
A
/
FV
Size ISO 7368:
1
6; 25; 32; 40; 50
Safety cartridge
v
alve according
t
o ISO 7368
optional pilot valve:
-
=omit if not required
H =with NG 6 pilot valve
Only for LIDAH
V
oltage code, see section
10
Only for LIDAH
X
= without connector, to be order separately
see section
11
4
MODEL CODE OF LIDA SAFETY VALVES (integral design cover)
P
i
l
o
t
s
o
l
e
n
o
i
d
v
a
l
v
e
o
n
l
y
f
o
r
L
I
D
A
H
I
=
D
H
I
f
o
r
A
C
a
n
d
D
C
s
u
p
p
l
y
-
P
m
a
x
3
5
0
b
a
r
E
=
D
H
E
P
f
o
r
A
C
a
n
d
D
C
s
u
p
p
l
y
,
h
i
g
h
p
e
r
f
o
r
m
a
n
c
e
s
,
P
m
a
x
4
2
0
b
a
r
s
pring cracking pressure:
1 = 0,6 bar 3 = 3 bar 6 = 5,5 bar
Poppet position monitor:
F
V
=
inductive position switch (double contact)
S
eries number
Seals material:
o
mit for NBR
(mineral oil &
w
ater glycol)
P
E = FKM
p
o
p
p
e
t
t
y
p
e
:
4
3
=
w
i
t
h
d
a
m
p
i
n
g
n
o
s
e
a
r
e
a
r
a
t
i
o
1
:
5
LIDA H
2
5
4
3
3 FV I X 24DC ** *
/-/
-
EY120
4.1
5.1
A
B
X
A
B
XY
POPPET CHARACTERISTICS OF LIFI AND LIDA(H)/FV
Operating pressure
5
MAIN CHARACTERISTICS OF LIFI AND LIDA(H)/FV
Assembly position / location
Subplate surface finishing Roughness index Ra 0,4 - flatness ratio 0,01/100 (ISO 1101)
MTTFd values according to EN ISO 13849 75 years, for further details see technical table P007
Flow direction AB or BA
Ambient temperature
Standard = -30°C ÷ +70°C
/PE option = -20°C ÷ +70°C
Any position
A, B, X, Z1, Z2 = 420 bar
L
I
F
I
A
,
B
,
X
= 4
2
0
ba
r
;
A
,
B
,
X
=
L
I
DA
H-
I
=
3
5
0
ba
r
;
L
I
DA
H-
E
4
2
0
ba
r
Y
=
L
I
DA
H-
I
=
1
2
0
ba
r
;
L
I
DA
H-
E
(
DC)
2
1
0
ba
r
;
L
I
DA
H-
E
(
A
C)
1
6
0
ba
r
;
LI
DA/
FV
LI
DAH/
FV
43
42 (only LIFI)
Poppet type
Functional sketch
(Hydraulic symbol)
Area ratio A/A
P
Opening pressure AÆB (1)
Opening pressure BÆA (1)
1:1,5
for size 16, 25
0,5bar (spring 1)
-
2,7bar (spring 3)
6 bar (spring 6)
0,5bar (spring 1)
-
2,4bar (spring 3)
6 bar (spring 6)
1:1,1
0,3bar (spring 1)
1,3bar (spring 2)
3,2bar (spring 3)
6 bar (spring 6)
3 bar (spring 1)
12,8bar (spring 2)
32,5bar (spring 3)
59,4bar (spring 6)
(1) Depending on the spring cracking pressure and the area ratio of the poppet
A
BB
AP
260 450
1300
830
1800
Si
ze
Ma
x
i
m
um
f
l
ow
a
t
D
p
=
5
b
a
r
[
l
/
m
i
n
]
po
ppe
t
4
2
,
4
3
16
25 32 40 50
A
AP
6
M
ODEL CODE OF LIDAS ACTIVE SAFETY PILOT OPERATED VALVES
Poppet areas of LIDAS/FV
S
ize ISO 7368:
1
6; 25; 32; 40; 50
A
ctive safety
c
artridges,
a
ccording to
I
SO 7368
O
ptional pilot valve
:
- = without pilot solenoid
v
alve
H = with pilot solenoid valve
O
nly for LIDASH
voltage code, see section
10
O
nly for LIDASH
X
= without connector, to be order separately
see section
11
P
ilot solenoid valve only for LIDASH
I = DHI for AC and DC supply, Pmax 350 bar
E
= DHEP for AC and DC supply, high performances,
Pmax 420 bar
S
pring cracking pressure
3
= 3 bar
Poppet position monitor:
F
V
=
inductive position switch (double contact)
S
eries number
Seals material:
o
mit for NBR
(
mineral oil &
water glycol)
P
E = FKM
P
o
p
p
e
t
t
y
p
e
:
4
3
=
w
i
t
h
d
a
m
p
i
n
g
n
o
s
e
L
IDAS/FV
G
H
Y
D
R
A
U
LI
C
S
Y
MB
O
LS
O
F
LI
D
A
S
L
IDASH-*/FV
G
LIDAS H
40 43
3 FV I X 24DC ** *
/-/
-
6.1
7.1
A
B
Z
1 X Z2 Y
C
A
B
Z1 X Z2 Y
C
1,43
58,6
107,0
265,6
3,46
41,7
90,5
232,2
5,30
51,5
85,2
236,7
8,04
56,3
87,9
244,1
13,85
41,7
97,8
239,2
Poppet characteristics [cm
2
]
A
A
AB (% of AA)
A
BP (% of AA)
A
AP (% of AA)
A
A / (AA + AB) poppet ratio
A
AP / (AA + AB) piloting ratio
Thanks to the areas ratio AAP/(AA+AB), the valve closing
is always ensured with a piloting pressure (X port) equal
to the line pressure (A or B line).
Poppet areas
AA = main flow (side A)
A
B = main flow (side B)
A
AP = piloting area (close)
A
BP = piloting area (open)
Operating pressure
7
MAIN CHARACTERISTICS OF LIDAS/FV
Assembly position / location
Subplate surface finishing Roughness index Ra 0,4 - flatness ratio 0,01/100 (ISO 1101)
MTTFd values according to EN ISO 13849 150 years, for further details see technical table P007
Flow direction AÆB or BÆA
Ambient temperature
Standard = -30°C ÷ +70°C
/PE option = -20°C ÷ +70°C
Any position
A, B, X, Z1, Z2 = 420 bar
LIDAS/FV
A
,
B
,
X,
Z1
,
Z2
=
L
I
DA
SH-
I
3
5
0
ba
r
;
L
I
DA
SH-
E
4
2
0
ba
r
;
Y
=
L
I
DA
SH-
I
1
2
0
ba
r
;
L
I
DA
SH-
E
(
DC)
2
1
0
ba
r
;
L
I
DA
SH-
E
(
A
C)
1
6
0
ba
r
;
LI
DAS
H/
FV
200
360
1100
550
1800
Si
ze
Max
i
mum fl
ow
at
D
p =
5 bar [l/min
16
25 32 40 50
0,6
1,6
Insulation class H (180°C) for DC coils (all versions) and AC coils (only DHI)
F (155°C) for AC coils (DHEP)
Due to the occuring surface temperatures of the solenoid coils, the European standards
EN ISO 13732-1 and EN ISO 4413 must be taken into account
Protection degree to DIN EN 60529 IP 65 (with connectors correctly assembled)
Relative duty factor 100%
Supply voltage and frequency See electric feature
Supply voltage tolerance ± 10%
Certification
CURUS North American standard
Mineral oils
H
ydraulic fluid
N
BR, FKM
F
KM
NBR
DIN 51524
ISO 12922
H
L, HLP, HLPD, HVLP, HVLPD
HFDU, HFDR
H
FC
Suitable seals type
C
lassification Ref. Standard
Flame resistant without water
Flame resistant with water
9
S
EALS AND HYDRAULIC FLUID
- for other fluids not included in below table, consult our technical office
Seals, recommended fluid temperature NBR seals (standard) = -20°C ÷ +60°C, with HFC hydraulic fluids = -20°C ÷ +50°C
FKM seals (/PE option) = -20°C ÷ +80°C
Recommended viscosity 15÷100 mm
2
/s - max allowed range 2,8 ÷ 500 mm
2
/s
Fluid contamination class ISO 4406 class 21/19/16 NAS 1638 class 10, in line filters of 25 mm (b25 _>75 recommended)
1
0
ELECTRIC FEATURES - coils for pilot solenoid valves
(1) Coil can be supplied also with 60 Hz of voltage frequency: in this
case the performances are reduced by 10÷15% and the power
consumption is 55 VA (-I) and 58 VA (-E)
(2) Average values based on tests performed at nominal hydraulic
condition and ambient/coil temperature of 20°C.
(3) When solenoid is energized, the inrush current is approx 3 times
the holding current. Inrush current values correspond to a power
consumption of about 150 VA.
(4) Only for pilot valve DHI
(5) Only for pilot valve DHEP
8
COILS CHARACTERISTICS
6 DC
12 DC
14 DC
24 DC
28 DC
48 DC
110 DC
125 DC
220 DC
24/50 AC
24/60 AC
48/50 AC
48/60 AC
110/50 AC
115/60 AC (5)
120/60 AC (4)
230/50 AC
230/60 AC
110/50 AC
120/60 AC
230/50 AC
230/60 AC
6 DC (4)
12 DC
14 DC
24 DC
28 DC
48 DC
110 DC
125 DC
220 DC
24/50/60 AC
(4)
48/50/60 AC
(4)
110/50/60 AC
115/60 AC
120/60 AC
230/50/60 AC
230/60 AC
110RC
230RC
666
or
667
669
33 W
60 VA
COU-6DC
COU-12DC
COU-14DC
COU-24DC
COU-28DC
COU-48DC
COU-110DC
COU-125DC
COU-220DC
COI-24/50/60AC (1)
COI-48/50/60AC (1)
COI-110/50/60AC (1)
-
COI-120/60AC
COI-230/50/60AC (1)
COI-230/60AC
COU-110RC
COU-230RC
33 W
DHI
-
COE-12DC
COE-14DC
COE-24DC
COE-28DC
COE-48DC
COE-110DC
COE-125DC
COE-220DC
-
-
COE-110/50/60AC
COE-115/60AC
-
COE-230/50/60AC
COE-230/60AC
COE-110RC
COE-230RC
DHEP
brown
green
brown
red
silver
silver
gold
blue
black
pink
white
yellow
white
light blue
silver
gold
blue
Colour of coil label
DHI
DHI
DHEP
Voltage
code
Valve
External supply
nominal voltage
± 10%
Type of
connector
Code of spare coil
Power
consumption
(3)
DHI
DHEP
30 W
30 W
58 VA
80 VA
-
58 VA
80 VA
-
-
60 VA
EY120
1
2 TECHNICAL CHARACTERISTICS
O
F INDUCTIVE PROXIMITY AND POSITION SWITCHES
Supply voltage [V]
Ripple max [%]
M
ax current [mA]
M
ax peak pressure [bar]
Mechanical life
Switch logic
v
irtually infinite
PNP
/FI proximity
sensor
1
0÷30
£
20
200
500
v
irtually infinite
P
NP
2
4
1
o
utput signal
s
u
p
p
l
y
+
2
4
V
D
C
GND
T
ype of switch
1
3 CONNECTING SCHEMES OF FI INDUCTIVE PROXIMITY AND FV POSITION SWITCHES
LIDA*/FV, LIDAS*/FV
1 = supply +24 V
DC
2 = output signal NC
3 = GND
4 = output signal NO
Notes:
-
FI and FV sensor’s connector are always supplied with the valve
- The /FI and /FV sensors are not provided with a protective earth connection
Connector type
ZBE-06
IP65
NO
NC
/
FV position
s
witch
20÷32
£
10
4
00
400
1
4
2
/FI scheme
1
3
4
2
s
upply +24 V
D
C
o
utput signal
output signal
GND
1
3
4
2
/FV scheme
14
A: overlapping stroke
B: damping stroke
FLOW
stroke
leakage
flow Q
According the criteria of safety specifications, the poppet position
signal must change its status inside the overlapping stroke (befo-
re the effective valve opening).
STATUS OF OUTPUT SIGNALS
SIGNAL
V
alve type
LIFI
LIDA*/FV, LIDAS*/FV
LIFI
Connector type
BKS-B-20-4-03
black = output signal
brown = supply +24 VDC
blue = GND
CABLE LENGHT = 3 m
1
1
C
OILS ELECTRIC CONNECTORS FOR PILOT SOLENOID VALVES according to DIN 43650 (to be ordered separately)
666, 667 (for AC or DC supply) 669 (for AC supply)
6
66, 667
1 = Positive
2 = Negative
= Coil ground
6
69
1,2= Supply voltage V
A
C
3 = Coil ground
CONNECTOR WIRING
SUPPLY VOLTAGES
6
66
A
ll
v
oltages
6
6
7
2
4
A
C
o
r
D
C
1
1
0
A
C
o
r
D
C
2
2
0
A
C
o
r
D
C
6
69
1
10/50 AC
1
10/60 AC
2
30/50 AC
2
30/60 AC
2
8.5
30
42
27
27
30
3
9.5
42.5
29
29
WARNING: the inobservance of following prescriptions invalidates the certification and may represent a risk for personnel injury
Safety valves must be installed and commissioned only by qualified personnel
Safety valves must not be disassembled
The inductive proximity FI or the inductive position switch FV can be adjusted only by the valve’s manufacturer or Atos authorized
service centers
Valve’s components cannot be interchanged
The valves must operate without switching shocks and spool vibrations
1
5
Q
/Dp DIAGRAMS based on mineral oil ISO VG 46 at 50 °C
EY120
Flow [l/min]
Valve pressure drop Dp [bar]
0
2
4
6
8
10
50
100 150
200
250
Flow [l/min]
Valve pressure drop Dp [bar]
0
2
4
6
8
10
100
200 300
400
500
Flow [l/min]
Valve pressure drop Dp [bar]
0
2
4
6
8
10
200
400 600
800
1000
Flow [l/min]
Valve pressure drop Dp [bar]
0
2
4
6
8
10
300
600 900
1200
1500
Flow [l/min]
Valve pressure drop Dp [bar]
0
2
4
6
8
10
500
1000 1500
2000
2500
SIZE 16 SIZE 25 SIZE 32
SIZE 40 SIZE 50
1 = LIDAS*-1643
2 = LIDAS*-2543
3 = LIDAS*-3243
4 = LIDAS*-4043
5 = LIDAS*-5043
1
2
3
4
5
15.2 Q/Dp DIAGRAMS OF LIDAS/FV
15.1 Q/Dp DIAGRAMS of LIFI and LIDA(H)/FV
Valve pressure drop Dp [bar]
F
low rate [l/min]
s
ize 16 size 25
size 40
s
ize 32
Valve pressure drop Dp [bar]
F
low rate [l/min]
Valve pressure drop Dp [bar]
F
low rate [l/min]
Valve pressure drop Dp [bar]
F
low rate [l/min]
32
33
4
2
43
3
2
33
42
4
3
3
2
3
3
4
2
4
3
32
3
3
42
4
3
3
2, 33: poppet type 32 and 33
42, 43: poppet type 42 and 43
s
ize 50
Valve pressure drop Dp [bar]
F
low rate [l/min]
3
2
3
3
4
2, 43
Note: for cover interface and cavity dimensions ISO 7368, see table P006
18
INSTALLATION DIMENSIONS of LIDA*/FV and LIDAS*/FV SAFETY CARTRIDGES [mm] (examples in size 32)
LIDA-*/FV, LIDAH-*/FV
BxB
A
B2
B1
Connector ZBE-06
supplied with the valve
03/17
A
95
95
BxB
B
2
B1
86 max
86 max
LIDAS-*/FV, LIDASH-*/FV
Pilot valve only
for LIDAH-*/FV
Pilot valve only
for LIDASH-*/FV
4 OR 108
4 OR 108
4 OR 2043
4 OR 2050
4 OR 2050
Size
A
B
B
2
LIDA
50 65x80 39.5
1 OR 108
1 OR 108
1 OR 2043
1 OR 2050
1 OR 2050
4 M8x50
4 M12x55
4 M16x70
4 M20x80
4 M20x80
35
125
300
600
600
50 85 42.5
65 100 50
65 125 62.5
65
A
85
85
85
85
85140 70
16
25
32
40
50
B1
40.5
42.5
50
62.5
70
B2
39.5
42.5
50
62.5
70
B
65x80
85
100
125
140
4 M8x70
4 M12x80
4 M16x70
4 M20x80
4 M20x80
B
65
85
100
125
140
B
65x72
85
100
125
140
A
85
98
107
110
130
A
95
115
116
125
135
Fastening bolts
4 M8x80
4 M12x95
4 M16x105
4 M20x70
4 M20x80
LIDAH
LIDAS, LIDASH
Seal
LIDA
OTHER
B1
40.5
42.5
50
62.5
70
B2
39.5
42.5
50
62.5
70
B2
39.5
42.5
50
62.5
70
B1
39.5
42.5
50
62.5
70
B1
32.5
42.5
50
62.5
70
LIDA LIDAH LIDAS LIDASH
Tightening
torque (
Nm
)
Connector ZBE-06
supplied with the valve
17
E
XAMPLES OF LIFI COUPLED WITH OTHER COVERS (examples in size 32)
1
6
DIMENSIONS of LIFI SAFETY COVERS [mm]
A B H H1 H2 L P
LIFI-16 54,5 94 50 25 56 72 65
LIFI-25 54,5 97 55 28 59 85 85
LIFI-32 47 97 60 28 59 100 100
LIFI-40 41 103,5 60 30 61 125 125
LIFI-50 44 114 70 30 61 140 140
L
IDA-3/F
LIFI-3242*/NC
LIDEW1-3/F-EX 24DC
LIFI-3242*/NC
LIDB-3/F
LIFI-3242*
L
IDBH1A-3/F-EX 24DC
LIFI-3242*
N
ote: for cover interface and cavity dimensions ISO 7368, see table P006
XY XY