4 NOTES
4.1 Options
/A = Solenoid mounted at side of port A of main body (only for single solenoid valves). In standard version, solenoid is mounted at side of port B.Inter
/D = Internal drain (standard configuration is external drain)
/E = External pilot pressure (standard configuration is internal pilot pressure).
/FV = With proximity switch for spool position monitoring: see tab. E110.
/H = Adjustable chokes (meter-out to the pilot chambers of the main valve).
/H9 = Adjustable chokes (meter-in to the pilot chambers of the main valve).
/R = Pilot pressure generator (4 bar on port P - not for DPH*-1, see section .
/S = Main spool stroke adjustment (not for DPH*-1).
/WP = Prolonged manual override protected by rubber cap.
/L1, /L2, /L3 =
Device for main spool switching time control (dimension of calibrated restrictors on A and B ports of the pilot valve: L1 =0,8mm, L2 =1mm, L3 =1,25mm)
4.2 Spools
- spools type 0 and 3 are also available as 0/1 and 3/1. With them, when in centre position, oil passage from ports to tank are restricted.
- spools type 1, 4, 5, 58, 6 and 7 are also available as 1/1, 4/8, 5/1, 58/1, 6/1 and 7/1 (1/1, 6/1 and 7/1 only for DPH*-2, -4, -6) that are properly shaped to reduce
water-hammer shocks during the switching (to use with option /L*).
- other types of spools can be supplied on request.
10
For other available connectors, see tab. E010, E015 and K500
5
ELECTRONIC CONNECTORS ACCORDING TO DIN 43650 - the connectors must be ordered separately
Code of
connector
Function
SP-669 With built-in rectifier bridge for supplying DC coils by alternating current (AC 110V and 230V - Imax 1A)
As SP-666 connector IP-65 but with built-in signal led, suitable for direct connection to electric supply source
SP-666 Connector IP-65, suitable for direct connection to electric supply source
SP-667
Installation position
Subplate surface finishing Roughness index Ra 0,4 - flatness ratio 0,01/100 (ISO 1101)
Ambient temperature from -20°C to +70°C
Fluid Hydraulic oil as per DIN 51524 .... 535; for other fluids see section
Recommended viscosity 15 ÷ 100 mm
2
/s at 40°C (ISO VG 15 ÷ 100)
Fluid contamination class ISO 4406 class 21/19/16 NAS 1638 class 10, in line filters of 10 μm (β10 _>75 recommended)
Fluid temperature -20°C +60°C (standard and /WG seals) -20°C +80°C (/PE seals)
Flow direction As shown in the symbols of tables
Operating pressure
Rated flow See diagrams Q/Δp at section
Maximum flow
Any position for all valves except for type -*70 (without springs) that must be installed with horizontal
axis if operated by impulses.
DPH*-1: 160 l/min; DPH*-2: 300 l/min; DPH*-3: 650 l/min; DPH*-4: 700 l/min; DPH*-6: 1000 l/min
(
see rated flow at section
and operating limits at section
)
3 MAIN CHARACTERISTICS OF SOLENOID DIRECTIONAL VALVES TYPE DPHI, DPHE and DPHER
6 ELECTRIC FEATURES
3.1 Coils characteristics
Insulation class H (180°C) for DC coils (all versions) and AC coils (only DPHI)
F (155°C) for AC coils (only DPHE and DPHER)
Due to the occuring surface temperatures of the solenoid coils, the European standards
EN563 and EN ISO 4413 must be taken into account
Connector protection degree IP 65
Relative duty factor 100%
Supply voltage and frequency See electric feature
Supply voltage tolerance ± 10%
Certification (only DPHI and DPHER)
CURUS North American standard
6 DC
12 DC
14 DC
24 DC
28 DC
48 DC
110 DC
125 DC
220 DC
24/50 AC
24/60 AC
48/50 AC
48/60 AC
110/50 AC
115/60 AC (5)
120/60 AC (4)
230/50 AC
230/60 AC
110/50 AC
120/60 AC
230/50 AC
230/60 AC
6 DC (4)
12 DC
14 DC
24 DC
28 DC
48 DC
110 DC
125 DC
220 DC
24/50/60 AC
(4)
48/50/60 AC
(4)
110/50/60 AC
115/60 AC
120/60 AC
230/50/60 AC
230/60 AC
110RC
230RC
SP-666
or
SP-667
SP-669
33 W
(DPHI)
30 W
(DPHE,
DPHER)
60 VA
(DPHI)
58 VA
(DPHE,
DPHER)
(3)
SP-COU-6DC/ 80
SP-COU-12DC /80
SP-COU-14DC /80
SP-COU-24DC /80
SP-COU-28DC /80
SP-COU-48DC /80
SP-COU-110DC /80
SP-COU-125DC /80
SP-COU-220DC /80
SP-COI-24/50/60AC /80 (1)
SP-COI-48/50/60AC /80 (1)
SP-COI-110/50/60AC /80 (1)
-
SP-COI-120/60AC /80
SP-COI-230/50/60AC /80 (1)
SP-COI-230/60AC /80
SP-COU-110RC /80
SP-COU-230RC /80
40 VA
35 VA
40 VA
35 VA
DPHI
-
SP-COE-12DC /10
SP-COE-14DC /10
SP-COE-24DC /10
SP-COE-28DC /10
SP-COE-48DC /10
SP-COE-110DC /10
SP-COE-125DC /10
SP-COE-220DC /10
-
-
SP-COE-110/50/60AC /10
SP-COE-115/60AC /10
-
SP-COE-230/50/60AC /10
SP-COER-230/60AC /10
SP-COE-110RC /10
SP-COE-230RC /10
DPHE
-
SP-COER-12DC /10
SP-COER-14DC /10
SP-COER-24DC /10
SP-COER-28DC /10
SP-COER-48DC /10
SP-COER-110DC /10
SP-COER-125DC /10
SP-COER-220DC /10
-
-
SP-COER-110/50/60AC /10
SP-COER-115/60AC /10
-
SP-COER-230/50/60AC /10
SP-COER-230/60AC /10
SP-COER-110RC /10
SP-COER-230RC /10
DPHER
brown
green
brown
red
silver
silver
gold
blue
black
pink
white
yellow
white
light blue
silver
gold
blue
Colour of coil label DPHI
DPHI
DPHE
DPHER
Voltage
code
Valve
External supply
nominal voltage
± 10%
Type of
connector
Power
consumption
(2)
Code of spare coil
P, A, B, X = 350 bar
T = 250 bar for external drain (standard)
T and Y with internal drain (option /D) = 120 bar DPHI; 210 bar DPHE(R) (DC); 160 bar DPHE(R) (AC)
Ports Y and L (if required): 0 bar
Minimum pilot pressure for correct operation is 8 bar
(1) Coil can be supplied also with 60 Hz of voltage frequency: in this case the performances are reduced by 10÷15% and the power consumption is 55 VA (DPHI) and 58 VA (DPHE*)
(2) Average values based on tests performed at nominal hydraulic condition and ambient/coil temperature of 20°C.
(3) When solenoid is energized, the inrush current is approx 3 times the holding current. Inrush current values correspond to a power consumption of about 150 VA.
(4) Only for DPHI
(5) Only for DPHE and DPHER