Atos spa
21018 Sesto Calende, Italy - Fax 0331 920005
Solenoid directional valves type DKI, DKU, DKOR
direct operated, ISO 4401 size 10
Table E020-11/E
DKI,DKU and DKOR are spool type,
three or four way, two or three position
direct operated solenoid valves desi-
gned to operate in oil hydraulic
systems.
They are operated by wet and pressure
sealed solenoid with manual overri-
de:
AI solenoid suitable for AC supply;
AU solenoid for DC supply with
improved performance;
AOR solenoid for DC supply with
high performance.
Moving parts are protected, lubricated
and cushioned in oil.
Shell-moulding casting are 5 cham-
bers machined by transfer lines and
then cleaned by thermal deburring.
Optimized flow paths largely cored with
extrawide channels to tank for low
pressure drops.
Interchangeable spools available in
a wide variety of configurations.
DKU and DKOR valves can be sup-
plied with optional devices for control
of switching times.
Standard electric/electronic connectors
able to satisfy the requirements of
modern machines for electric interfa-
ces characteristics.
Coils are fully encapsulated (class H).
In DKI and DKU coils are easily repla-
ceable without the aid of tools.
Rugged execution suitable for outdoor
use.
Surface mounting ISO 4401 size 10.
Max flow up to 100 l/min for DKI/DKU
and up to 120 l/min for DKOR.
Max pressure: 315 bar.
DKI – 1
Directional control valves ISO 4401 size 10
DKI-1 = solenoid AI for AC supply
DKU-1 = solenoid AU for DC supply
DKOR-1= solenoid OO for DC supply
Valve configuration, see table
61 = single solenoid, center plus external position,
spring centered
63 = single solenoid, 2 external positions, spring offset
67 = single solenoid, center plus external position,
spring offset
70 = double solenoid, 2 external positions, without
springs
71 = double solenoid, 3 positions, spring centered
75 = double solenoid, 2 external positions, with detent
77 = double solenoid, center plus external position,
without springs
Other configurations are available on request.
Spool type, see table
.
Design number
Synthetic fluids
WG =water glycol
PE= phosphate ester
/A **63 /*
1 MODEL CODE
E020
1/2
Options, see note 1 at section
.
X 24 DC
External supply voltage see section
00 = valve without coils (only for DKI and
DKU).
-
X = without connector
See note 2 at section
for available connectors,
to be ordered separately
BLEED SCREW
BLEED SCREW
DKI
DKU
DKOR
3
SPOOLS - for intermediate passages, see tab. E001.
See note 3 at section
.
0
0/2
7
94
1
1/2
8
49
2
2/2
90
16
3
09
17
4
91
58
5
19
5/1
93
6
39
connector
connector
Where the symbol doesn't show the hydraulic con-
nection (*), it depends on the central configuration of
the spool; see table
.
2 CONFIGURATION
-171*
-1630/2/A
-1631/2/A
-1700/2
-1701/2
-161*/A
-1750/2
-1751/2
-167*/A
-177*
-1630/2
-1631/2
-161* -167*
Assembly position / location
Commissioning
Subplate surface finishing Roughness index flatness ratio 0,01/100 (ISO 1101).
Ambient temperature from -20°C to +70°C.
Fluid Hydraulic oil as per DIN 51524 .... 535; for other fluids see section .
Recommended viscosity 15 ÷ 100 mm
2
/s at 40°C (ISO VG 15 ÷ 100).
Fluid contamination class ISO 19/16, achieved with in line filters at 25 µm value to β
25
75 (recommended).
Fluid temperature -20°C +60°C (standard and /WG seals) -20°C +80°C (/PE seals)
Flow direction As shown in the symbols of tables and .
Operating pressure
Rated flow See diagrams Q/p at section .
Maximum flow 100 l/min for DKI and DKU; 120 l/min for DKOR, see operating limits at section .
For correct AC operation, the valve must be full of hydraulic fluid, otherwise some vibrations may
occur. In this case fill the valve with oil by opening the screw , see sketch at section and .
A check valve on T line aids to keep valve full.
4
MAIN CHARACTERISTICS OF DKI, DKU AND DKOR DIRECTIONAL VALVES
5 NOTES
1 Options
A = Solenoid mounted at side of port B (only for single solenoid valves). In standard versions, solenoid is mounted at side of port A.
WP = prolonged manual override protected by rubber cap (standard for DKOR models).
L, L1, L2, L3, LR, see sec. = device for switching time control (only for DKU and DKOR models).
Not available for valves with connectors E-SA or E-SE. For spools 4, 4/8, 5/1 only device L1 is available.
F * = with proximity switch for monitoring spool position: see tab. E110.
Y = external drain - not available for DKI-163* and DKI-175* (standard for versions with proximity switches /F*)
2 Type of electric/electronic connector with connector DIN 43650 to be ordered separately
SP-666 = standard connector IP-65 for direct connection to electric supply source.
SP-667 = as SP-666, but with built-in signal led.
SP-669 = with built-in rectifier bridge for supplying DC coils by alternate current (AC 110V and 230V - Imax 1A).
E-SA =
electronic connector (only for DKI and DKU valves) which improves performances and give faster shifting times for DC solenoid supplied by AC power.
E-SE = electronic connector (only for DKI and DKU valves) which improves performances and reduces power consumption for DC solenoid sup-
plied by DC power.
E-SR = electronic connector which permits switching of solenoid valves by a low power signal (max 20mA).
E-SD = electronic connector which eliminates electric disturbances when solenoid valves are de-energized.
Note: disturbance suppressor devices, similar to E-SD are, standard, built in all E-SA, E-SE, E-SR.
3 Spools
- spools type 0/2, 1/2, 2/2 are only used for two position valves: single solenoid valves, type DK*-163*/2; double solenoid valves type DK*-170*/2
and DK*-175*/2.
- spools type 0 and 3 are also available as 0/1 and 3/1 that, when in centre position, oil passage from ports to tank are restricted.
- spools type 1,4 and 5 are also available as 1/1, 4/8 and 5/1. They are properly shaped to reduce water-hammer shocks during the swiching.
Note that the configuration of spool 5/1 is inverted in respect with spool 5: see section .
- spools type 1,3 and 1/2 are also available as 1P, 3P and 1/2P to limit valve leackage.
- Other types of spools can be supplied on request.
10
10 11
Any position for all valves except for type - 170* (without springs) that must be installed with horizontal
axis if operated by impulses
(1) Coil can be supplied also with 60 Hz of volta-
ge frequency: in this case the performances
are reduced by 10÷15% and the power
consumption is 90 VA.
(2) Average values based on tests performed at
nominal hydraulic condition and ambient/coil
temperature of 20°C.
(3) In a cycle, where solenoid is energized/dee-
nergized in 1 second (1 Hz), the average
power consumption is 13 W; for longer cycles,
the power consumption is lower.
When solenoid is energized the inrush current
is 9 A at 12 V
DC and 6 A at 24 VDC correspon-
ding to power consumption peak of 130 W.
These current peaks persist for a period
shorter than 100 msec and they must be
considered when electric circuit is designed.
(4) When solenoid is energized the inrush cur-
rent is 7 A at 110 V
AC and 3,5 A at 230 VAC;
the power consumption peak is 800 VA;
these current peaks persist for a period shor-
ter than 40 msec and they must be conside-
red when electric circuit is designed.
(5) When solenoid is energized, the inrush cur-
rent is approx 3 times the holding current.
Inrush current values correspond to a power
consumption of about 350 VA.
6 DC
9 DC
12 DC
14 DC
18 DC
24 DC
28 DC
48 DC
110 DC
125 DC
220 DC
24/50 AC
24/60 AC
48/50 AC
48/60 AC
110/50 AC
120/60 AC
230/50 AC
230/60 AC
12 DC
24 DC
110/50 AC
120/60 AC
230/50 AC
230/60 AC
110/50 AC
120/60 AC
230/50 AC
230/60 AC
SP-666
or
SP-667
E-SE
E-SA
(4)
SP-669
52 W
110 VA
(5)
-
-
-
-
-
-
-
-
-
-
-
SP-CAI-24/50/60AC /80 (1)
SP-CAI-48/50/60AC /80 (1)
SP-CAI-110/50/60AC /80 (1)
SP-CAI-120/60AC /80
SP-CAI-230/50/60AC /80 (1)
SP-CAI-230/60AC /80
-
-
-
-
-
-
SP-CAU-6DC/ 80
SP-CAU-9DC /80
SP-CAU-12DC /80
SP-CAU-14DC /80
SP-CAU-18DC /80
SP-CAU-24DC /80
SP-CAU-28DC /80
SP-CAU-48DC /80
SP-CAU-110DC /80
SP-CAU-125DC /80
SP-CAU-220DC /80
-
-
-
-
SP-CAU-6DC /80
SP-CAU-12DC /80
SP-CAU-24DC /80
SP-CAU-48DC /80
SP-CAU-110RC /80
SP-CAU-230RC /80
brown
light blue
green
brown
blue
red
silver
silver
gold
blue
black
yellow
white
light blue
silver
green
red
silver
gold
blue
13 W (3)
105 VA
95 VA
105 VA
95 VA
58 VA
53 VA
58 VA
53 VA
6 ELECTRIC FEATURES
Valve
External supply
nominal voltage
± 10%
Type of
connector
Power
consumption
(2)
Code of spare coil
DKI DKU
Colour of
coil label
DKI
DKU
12 DC
24 DC
110 DC
220 DC
SP-666
or
SP-667
40 W
46 W
DKO
Valve
External supply
nominal voltage
± 10%
Type of
connector
Power
consumption
(2)
110/50 AC
120/60 AC
230/50 AC
230/60 AC
SP-669
46 W
42 W
46 W
42 W
DKOR
Valve
External supply
nominal voltage
± 10%
Type of
connector
Power
consumption
(2)
Ports P,A,B: 315 bar;
Port T: 120 bar for DKI; 160 bar for DKU and 210 bar for DKOR; 315 bar for option Y.
For versions with proximity switches (/FI/NC and /FI/NO versions) port Y must be drained
4.1 Coils characteristics
Insulation class H (180°C) Due to the occuring surface temperatures of the solenoid coils, the European standards
EN563 and EN982 must be taken into account
Connector protection degree IP 65
Relative duty factor 100%
Supply voltage and frequency See electric feature
Supply voltage tolerance ± 10%
E020
7
Q/P DIAGRAMS based on mineral oil ISO VG 46 at 50°C
M =Spools 0, 1, 1/2, 3.
Y = Spools 0/2, 4, 5, 6, 7.
V = Spools 2, 2/2, *9, 9*.
X = Spools 0, 0/2, 1, 1/2, 3, 6, 7, 8 with E-SA or E-SE
connector.
M = Spools 0, 1, 1/2, 8.
S = Spools 0/2, 3, 6, 7.
Y = Spools 2, 2/2, *9, 9* with E-SA or E-SE connectors.
V = Spools 2, 2/2, *9, 9*.
T = Spools 4, 5.
M = Spools 0, 0/2, 1, 1/2, 8.
S = Spools 3, 6, 7.
V = Spools 2, 2/2, *9, 9*
T = Spools 4, 5.
10 DEVICES FOR SWITCHING TIME CONTROL
These devices are only available for DKU and DKOR without E-SA or E-SE and can
check the switching time and therefore reduce the coil hammering in the circuit. The
different types available are shown in the figure.
The functionality of the device depends on the type of regulating element.
- L : checks and regulates the switching time in both moving directions of the spool:
regulation is carried out by screwing/unscrewing the element itself (regulating
choke);
- L1/L2/L3: checks the switching time in both moving directions of the spool with fixed
regulation of this time (gauged flow)
ØL1 = 1,25 mm; ØL2 = 1 mm; ØL3 = 0,75 mm;
- LR checks and regulates the switching time in the ba direction of the spool move-
ment. The device does not intervene in the control of the switching time (standard
time) in the opposite direction ab of the spool movement.
In all cases where it is necessary to obtain damped switching, pair these devices with
progressive spools (1/1, 4/8, 5/1) which in the intermediate passages are properly sha-
ped to reduce reversal shocks.
The passage in which the regulating element is inserted must be completely full of fluid
for it to function properly, see also “commissioning” at section
.
0, 2, 3 B B B B
0/2, 1, 8 B B A A
1/2, 2/2 C C B B
4, 5, 9* DDDDC
6 BBAB
7 BBBA
Flow direction
Spool type
PAPBATBTPT
SPOOL DIRECTION
a b =
sol. energizing “a” / sol. de-energizing “b”
a b =
sol. energizing “b” / sol. de-energizing “a”
9
SWITCHING TIMES (average values in msec)
DKU + –– 60 30
DKU + SP-669 60 –– 90
DKU + E-SA 25 –– 45
DKU + –– 60 60
DKU + E-SE –– 40 40
DKU-*/L* –– 75-150 45-150
Valve Switch-on Switch-on Switch-off
AC DC
DKOR + SP-669 65 –– 95
DKOR-1**/L* –– 75-150 50-150
Valve Switch-on Switch-on Switch-off
AC DC
Test conditions:
- 50 l/min; 150 bar
- nominal voltage
- 2 bar of counter pressure on port T
- mineral oil ISO VG 46 at 50°C
The elasticity of the hydraulic circuit and the variations of the hydraulic characteristics and temperature affect the response time.
DKU DKOR
SP-666
SP-667
E-SD
E-SR
DKOR + –– 65 35
DKOR + –– 65 65
SP-666
SP-667
E-SD
E-SR
DKI - DKU
D
B
A
C
Valve pressure drop p [bar]
Flow rate [l/min]
D
B
A
C
Valve pressure drop p [bar]
Flow rate (l/min)
DKOR
Flow rate [l/min]
Inlet pressure [bar]
X
Y
V
Inlet pressure [bar]
Flow rate [l/min]
Inlet pressure [bar]
Flow rate [l/min]
DKORDKUDKI
M
T
S
V
M
T
S
8
OPERATING LIMITS based on mineral oil ISO VG 46 at 50°C
The diagrams have been obtained with warm solenoids and power supply at lowest value (Vnom - 10%). The curves refer to application with symmetrical flow
through the valve (i.e. PA and BT). In case of asymmetric flow and if the valves have the devices for controlling the switching times the operating limits
must be reduced.
M
Y
V
DKI + 35 60 30
Valve Switch-on Switch-on Switch-off
AC DC
DKI
SP-666
SP-667
Mounting surface
ISO 4401-AC-05-4 size 10
Fastening bolts: 4 socket head screws M6x40
Seals: 5 OR 2050.1 OR 108
Ports P,A,B,T: Ø = 11.5 mm (max)
Ports Y: Ø = 5 mm
11
INSTALLATION DIMENSIONS [mm]
09/04
13 MOUNTING SUBPLATES
Model Ports location
GAS Ports
A-B-P-T (X-Y)
Ø Counterbore
[mm]
A-B-P-T (X-Y)
Mass
[kg]
BA-308 (/Y)
BA-428 (/Y)
BA-434 (/Y)
Ports A, B, P, T (X, Y) underneath
Ports A, B, P, T (X, Y) underneath
Ports P, T, (X, Y) underneath; Ports A, B on lateral side
1/2" (1/4")
3/4" (1/4")
3/4" (1/4")
30 (21,5)
36,5 (21,5)
36,5 (21,5)
2,5
5,5
8,5
The subplates are supplied with 4 fastening bolts M6x40. Also available are multi-station subplates and modular subplates. For further details see table K280.
P = PRESSURE PORT
A, B = USE PORT
T = TANK PORT
Y = DRAIN PORT (only for option /Y)
For the max pressures on ports, see section
Mass: 3,8 kg Mass: 4,4 kg
DKI-16
DKU-16
DKI-17
DKU-17
Mass: 4,9 kg Mass: 6,1 kg
DKOR-16 DKOR-17
Overall dimensions refer to valves with connectors type SP-666
12
ELECTRIC/ELECTRONIC CONNECTORS ACCORDING TO DIN 43650 - The connectors must be ordered separately
SP-669
(for AC supply)
E-SA (for AC supply)
E-SE (for DC supply)
E-SR/AC (for AC supply)
E-SR/DC (for DC supply) E-SD/AC
(for AC supply)
SP-666, SP-667
(for AC or DC supply)
E-SD/DC
(for DC supply)
SP-666, SP-667
1 = Positive
2 = Negative
= Coil ground
SP-666 SP-667 E-SD-DC
AC or DC
All 24 All DC
voltages 110 voltages
220
E-SA E-SE E-SR-AC
110/50 AC
12 DC All
120/60 AC
24 DC voltages
230/50 AC
230/60 AC
110/50 AC
120/60 AC
230/50 AC
230/60 AC
12 DC
24 DC
All AC voltages
1,2 = Supply voltage VACPower supply V
DC:
RED = Positive
BLUE = Ground
Pilot signal V
DC:
YELLOW = Positive
+24VDC
WHITE = Negative
E-SA
1,2 = Supply voltage V
AC
3 = Coil ground
E-SE
1 = Positive 2 = Negative
E-SR/AC
1,2 = Supply voltage V
AC
3 = Coil ground
4 = Negative pilot signal VDC
5 = Positive pilot signal +24VDC
SP-669
1,2 = Supply voltage VAC
3 = Coil ground
Supplied with 5 m long cable.
YELLOW
WHITE
RED
BLUE
CONNECTOR WIRING
SUPPLY VOLTAGES