4.1 Coils characteristics
5 NOTES
1 Options
A = Solenoid mounted at side of port B (only for single solenoid valves). In standard versions, solenoid is mounted at side of port A.
WP = prolonged manual override protected by rubber cap - see section .
SP-WPD/H = manual override with detent, to be ordered separately, see tab. K150
L1, L2, L3 = device for switching time control, installed in the valve solenoid (only for DHU models).
For spools 4 and 4/8 only device L3 is available.
F * = with proximity switch for monitoring spool position: see tab. E110.
MV, MO = auxiliary hand lever positioned vertically (MV) or horizontally (MO). For available configuration and dimensions see table E138.
2 Type of electric/electronic connector DIN 43650, to be ordered separately
SP-666 = standard connector IP-65, suitable for direct connection to electric supply source.
SP-667 = as SP-666, but with built-in signal led.
SP-669 = with built-in rectifier bridge for supplying DC coils by alternate current (AC 110V and 230V - Imax 1A).
E-SD = electronic connector which eliminates electric disturbances when solenoid valves are de-energized.
3 Spools
- spools type 0/2, 1/2, 2/2 are only used for two position valves: single solenoid, type DH*-063*/2 and double solenoid type
DH*-070*/2 and DH*-075*/2 (only spools.
- spools type 0 and 3 are also available as 0/1 and 3/1 with restricted oil passages in central position, from user ports to tank.
- spools type 1, 4 and 5 are also available as 1/1, 4/8 and 5/1. They are properly shaped to reduce water-hammer shocks during the swiching.
- spools type 1, 3, 8 and 1/2 are available as 1P, 3P, 8P and 1/2P to limit valve internal leakages.
- spool type 1/9 has closed center in rest position but it avoids the pressurization of A and B ports due to the internal leakages.
- Other types of spools can be supplied on request.
12
(1) Coil can be supplied also with 60
Hz of voltage frequency: in this
case the performances are redu-
ced by 10 ÷15% and the power
consumption is 55 VA.
(2) Average values based on tests
preformed at nominal hydraulic
condition and ambient/coil tempe-
rature of 20°C.
(3) When solenoid is energized, the
inrush current is approx 3 times the
holding current. Inrush current
values correspond to a power con-
sumption of about 150 VA.
Insulation class H (180°C) Due to the occuring surface temperatures of the solenoid coils, the European standards
EN563 and EN982 must be taken into account
Connector protection degree DIN 43650 IP 65
Relative duty factor 100%
Supply voltage and frequency See electric feature
Supply voltage tolerance ± 10%
Certification
CURUS
Assembly position / location
Subplate surface finishing Roughness index flatness ratio 0,01/100 (ISO 1101)
Ambient temperature from -20°C to +70°C
Fluid Hydraulic oil as per DIN 51524 .... 535; for other fluids see section
Recommended viscosity 15 ÷ 100 mm
2
/s at 40°C (ISO VG 15 ÷ 100)
Fluid contamination class ISO 19/16, achieved with in line filters at 25 μm value to β
25
≥75 (recommended)
Fluid temperature -20°C +60°C (standard and /WG seals) -20°C +80°C (/PE seals)
Flow direction As shown in the symbols of tables and
Operating pressure
Rated flow See diagrams Q/Δp at section
Maximum flow 60 l/min see operating limits at section
Any position for all valves except for type - 070* (without springs) that must be installed with horizontal
axis if operated by impulses
4 MAIN CHARACTERISTICS OF DHI, DHU AND DHO DIRECTIONAL VALVES
DHI
DHU
Ports P,A,B: 350 bar;
Port T: 120 bar
Ports P,A,B: 350 bar;
Port T 210 bar
For versions with proximity swit-
ches (/FI/NC and /FI/NO versions)
maximum counter pressure
allowed on T port is 5 bar
6 DC
9 DC
12 DC
14 DC
18 DC
24 DC
28 DC
48 DC
110 DC
125 DC
220 DC
24/50 AC
24/60 AC
48/50 AC
48/60 AC
110/50 AC
120/60 AC
230/50 AC
230/60 AC
SP-666
or
SP-667
SP-669
33 W
60 VA
(3)
SP-COU-6DC/ 80
SP-COU-9DC /80
SP-COU-12DC /80
SP-COU-14DC /80
SP-COU-18DC /80
SP-COU-24DC /80
SP-COU-28DC /80
SP-COU-48DC /80
SP-COU-110DC /80
SP-COU-125DC /80
SP-COU-220DC /80
SP-COI-24/50/60AC /80 (1)
SP-COI-48/50/60AC /80 (1)
SP-COI-110/50/60AC /80 (1)
SP-COI-120/60AC /80
SP-COI-230/50/60AC /80 (1)
SP-COI-230/60AC /80
SP-COU-6DC/ 80
SP-COU-9DC /80
SP-COUR-12DC /10
SP-COUR-14DC /10
SP-COU-18DC /80
SP-COUR-24DC /10
SP-COUR-28DC /10
SP-COU-48DC /80
SP-COUR-110DC /10
SP-COU-125DC /80
SP-COUR-220DC /10
-
-
-
-
brown
light blue
green
brown
blue
red
silver
silver
black
silver
black
pink
white
yellow
white
light blue
silver
gold
blue
40 VA
35 VA
40 VA
35 VA
6
ELECTRIC FEATURES
Valve
External supply
nominal voltage
± 10%
Type of
connector
Power
consumption
(2)
Code of spare coil
DHI DHU
Colour of
coil label
DHI
DHU
110/50 AC
120/60 AC
230/50 AC
230/60 AC
SP-COU-110RC /80
SP-COU-230RC /80
SP-COUR-110RC /10
SP-COUR-230RC /10
Voltage
code
6 DC
9 DC
12 DC
14 DC
18 DC
24 DC
28 DC
48 DC
110 DC
125 DC
220 DC
24/50/60 AC
48/50/60 AC
110/50/60 AC
120/60 AC
230/50/60 AC
230/60 AC
110RC
230RC