Solenoid directional valves type DHI and DHU
direct operated, ISO 4401 size 06
Table E010-15/E
DHI and DHU are spool type, three or
four way, two or three position direct
operated solenoid valves designed to
operate in oil hydraulic systems.
They are operated by wet and pressure
sealed solenoid with manual overri-
de and with coils certified according
the North American standard
CURUS:
DHI for AC and DC supply;
DHU for DC supply with improved
performances.
Moving parts are protected, lubricated
and cushioned in oil.
Shell-moulding casting machined by
transfer lines and then cleaned by ther-
mal deburring.
Optimized flow paths largely cored with
extrawide channels to tank for low
pressure drops.
Interchangeable spools available in
a wide variety of configurations.
DHU valves can be supplied with
optional devices for control of swit-
ching times.
Standard electric/electronic connectors
able to satisfy the requirements of
modern machines for electric interfa-
ces characteristics.
Coils are fully encapsulated (class H)
and are easily replaceable without aid
of tools.
Rugged execution suitable for outdoor
use.
Surface mounting ISO 4401 size 06.
Max flow up to 60 l/min.
Max pressure: 350 bar.
DHI – 0
Directional control valves size 06
DHI-0 = AC and DC supply
DHU-0 = for DC supply
Valve configuration, see table
61 = single solenoid, center plus external position,
spring centered
63 = single solenoid, 2 external positions, spring offset
67 = single solenoid, center plus external position,
spring offset
70 = double solenoid, 2 external positions, without
springs
71 = double solenoid, 3 positions, spring centered
75 = double solenoid, 2 external positions, with detent
77 = double solenoid, center plus external position,
without springs
Other configurations are available on request.
Spool type, see table
.
Series number
Synthetic fluids
WG =water glycol
PE= phosphate ester
/A **63 /*
1 MODEL CODE
E010
3 SPOOLS - for intermediate passages, see tab. E001.
See note 3 at section
.
1/2
Options, see note 1 at section
.
X 24 DC
Voltage code, see section
00 = valve without coils
-
X = without connector
See note 2 at section
for available connec-
tors, to be ordered separately
Coils with special connectors, see section
XJ = AMP Junior Timer connector
XK= Deutsch connector
XS= Lead Wire connection
10
-071*
-0630/2/A
-0631/2/A
-0700/2
-0701/2
-061*/A
-0750/2
-0751/2
-067*/A -077*
-0630/2
-0631/2
-061* -067*
2 CONFIGURATION
Where the symbol doesn't show the hydraulic con-
nection (*), it depends on the central configuration
of the spool; see section .
DHU-0631/2
DHI-0711
connector
connector
.
.
.
햳햲햵햴
햳햲햵햴
.
.
.
.
1/9
Note: configuration 63 and 70 are available only with spools type 0/2, 1/2 and 2/2.
configuration 75 is available only with spools type 0/2 and 1/2.
.
4.1 Coils characteristics
5 NOTES
1 Options
A = Solenoid mounted at side of port B (only for single solenoid valves). In standard versions, solenoid is mounted at side of port A.
WP = prolonged manual override protected by rubber cap - see section .
SP-WPD/H = manual override with detent, to be ordered separately, see tab. K150
L1, L2, L3 = device for switching time control, installed in the valve solenoid (only for DHU models).
For spools 4 and 4/8 only device L3 is available.
F * = with proximity switch for monitoring spool position: see tab. E110.
MV, MO = auxiliary hand lever positioned vertically (MV) or horizontally (MO). For available configuration and dimensions see table E138.
2 Type of electric/electronic connector DIN 43650, to be ordered separately
SP-666 = standard connector IP-65, suitable for direct connection to electric supply source.
SP-667 = as SP-666, but with built-in signal led.
SP-669 = with built-in rectifier bridge for supplying DC coils by alternate current (AC 110V and 230V - Imax 1A).
E-SD = electronic connector which eliminates electric disturbances when solenoid valves are de-energized.
3 Spools
- spools type 0/2, 1/2, 2/2 are only used for two position valves: single solenoid, type DH*-063*/2 and double solenoid type
DH*-070*/2 and DH*-075*/2 (only spools.
- spools type 0 and 3 are also available as 0/1 and 3/1 with restricted oil passages in central position, from user ports to tank.
- spools type 1, 4 and 5 are also available as 1/1, 4/8 and 5/1. They are properly shaped to reduce water-hammer shocks during the swiching.
- spools type 1, 3, 8 and 1/2 are available as 1P, 3P, 8P and 1/2P to limit valve internal leakages.
- spool type 1/9 has closed center in rest position but it avoids the pressurization of A and B ports due to the internal leakages.
- Other types of spools can be supplied on request.
12
(1) Coil can be supplied also with 60
Hz of voltage frequency: in this
case the performances are redu-
ced by 10 ÷15% and the power
consumption is 55 VA.
(2) Average values based on tests
preformed at nominal hydraulic
condition and ambient/coil tempe-
rature of 20°C.
(3) When solenoid is energized, the
inrush current is approx 3 times the
holding current. Inrush current
values correspond to a power con-
sumption of about 150 VA.
Insulation class H (180°C) Due to the occuring surface temperatures of the solenoid coils, the European standards
EN563 and EN982 must be taken into account
Connector protection degree DIN 43650 IP 65
Relative duty factor 100%
Supply voltage and frequency See electric feature
Supply voltage tolerance ± 10%
Certification
CURUS
Assembly position / location
Subplate surface finishing Roughness index flatness ratio 0,01/100 (ISO 1101)
Ambient temperature from -20°C to +70°C
Fluid Hydraulic oil as per DIN 51524 .... 535; for other fluids see section
Recommended viscosity 15 ÷ 100 mm
2
/s at 40°C (ISO VG 15 ÷ 100)
Fluid contamination class ISO 19/16, achieved with in line filters at 25 μm value to β
25
75 (recommended)
Fluid temperature -20°C +60°C (standard and /WG seals) -20°C +80°C (/PE seals)
Flow direction As shown in the symbols of tables and
Operating pressure
Rated flow See diagrams Q/Δp at section
Maximum flow 60 l/min see operating limits at section
Any position for all valves except for type - 070* (without springs) that must be installed with horizontal
axis if operated by impulses
4 MAIN CHARACTERISTICS OF DHI, DHU AND DHO DIRECTIONAL VALVES
DHI
DHU
Ports P,A,B: 350 bar;
Port T: 120 bar
Ports P,A,B: 350 bar;
Port T 210 bar
For versions with proximity swit-
ches (/FI/NC and /FI/NO versions)
maximum counter pressure
allowed on T port is 5 bar
6 DC
9 DC
12 DC
14 DC
18 DC
24 DC
28 DC
48 DC
110 DC
125 DC
220 DC
24/50 AC
24/60 AC
48/50 AC
48/60 AC
110/50 AC
120/60 AC
230/50 AC
230/60 AC
SP-666
or
SP-667
SP-669
33 W
60 VA
(3)
SP-COU-6DC/ 80
SP-COU-9DC /80
SP-COU-12DC /80
SP-COU-14DC /80
SP-COU-18DC /80
SP-COU-24DC /80
SP-COU-28DC /80
SP-COU-48DC /80
SP-COU-110DC /80
SP-COU-125DC /80
SP-COU-220DC /80
SP-COI-24/50/60AC /80 (1)
SP-COI-48/50/60AC /80 (1)
SP-COI-110/50/60AC /80 (1)
SP-COI-120/60AC /80
SP-COI-230/50/60AC /80 (1)
SP-COI-230/60AC /80
SP-COU-6DC/ 80
SP-COU-9DC /80
SP-COUR-12DC /10
SP-COUR-14DC /10
SP-COU-18DC /80
SP-COUR-24DC /10
SP-COUR-28DC /10
SP-COU-48DC /80
SP-COUR-110DC /10
SP-COU-125DC /80
SP-COUR-220DC /10
-
-
-
-
brown
light blue
green
brown
blue
red
silver
silver
black
silver
black
pink
white
yellow
white
light blue
silver
gold
blue
40 VA
35 VA
40 VA
35 VA
6
ELECTRIC FEATURES
Valve
External supply
nominal voltage
± 10%
Type of
connector
Power
consumption
(2)
Code of spare coil
DHI DHU
Colour of
coil label
DHI
DHU
110/50 AC
120/60 AC
230/50 AC
230/60 AC
SP-COU-110RC /80
SP-COU-230RC /80
SP-COUR-110RC /10
SP-COUR-230RC /10
Voltage
code
6 DC
9 DC
12 DC
14 DC
18 DC
24 DC
28 DC
48 DC
110 DC
125 DC
220 DC
24/50/60 AC
48/50/60 AC
110/50/60 AC
120/60 AC
230/50/60 AC
230/60 AC
110RC
230RC
DHI + 304520
DHI + SP-669 45 –– 80
DHI + E-SD 30 45 50
DHI - DHU
E010
7
Q/ΔP DIAGRAMS based on mineral oil ISO VG 46 at 50°C
Flow rate [l/min]
8 OPERATING LIMITS based on mineral oil ISO VG 46 at 50°C
The diagrams have been obtained with warm solenoids and power supply at lowest value (V
nom - 10%). The curves refer to application with symmetrical
flow through the valve (i.e. P
A and BT). In case of asymmetric flow and if the valves have the devices for controlling the switching times the operating
limits must be reduced.
Inlet pressure [bar]
M = Spools 0, 1, 1/2, 8
S = Spools 0/2, 3, 6, 7
V = Spools 2, 2/2, *9, 9*
T = Spools 4, 5
M
S
T
V
V
Inlet pressure [bar]
Flow rate [l/min]
DHUDHI
M = Spools 0, 1, 1/2, 8
S = Spools 0/2, 3, 6, 7
V = Spools, 2, 2/2, *9, 9*
T = Spools 4, 5
Valve pressure drop Δp [bar]
Flow rate [l/min]
D
B
A
C
0 CCCC
0/2, 1, 1/2 A A A A
2, 3 A A C C
2/2, 4, 5, 9* DDDDA
6AACA
7AAAC
8CCBB
Flow direction
Spool type
PAPBATBTPT
9 SWITCHING TIMES (average values in msec)
Valve Switch-on Switch-on Switch-off
AC DC
Test conditions:
- 36 l/min; 150 bar
- nominal voltage
- 2 bar of counter pressure on port T
- mineral oil: ISO VG 46 at 50°C.
The elasticity of the hydraulic circuit and the variations of the hydraulic characteristics and temperature affect the response time.
DHI
M
TS
Note: The above coils are available only for voltage supply 12, 14, 24 and 28 V
DC. For the characteristics refer to standard coils features - see sect.
10 COILS TYPE COU* and COUR* WITH SPECIAL CONNECTORS
Options -XJ
Coil type SP-COUJ, SP-COURJ
AMP Junior Timer connector
Protection degree IP67
Options -XK
Coil type SP-COURK
(not available for COU)
Deutsch connector
DT-04-2P male
Protection degree IP67
Options -XS
Coil type SP-COUS, SP-COURS
Lead Wire connection
Cable lenght = 180 mm
DHU + –– 45 20
DHU + SP-669 45 –– 80
DHU + E-SD –– 45 50
DHU-*/L1 –– 60 60
DHU-*/L2 –– 80 80
DHU-*/L3 –– 110 150
DHU
SP-666
SP-667
Valve Switch-on Switch-on Switch-off
AC DC
SP-666
SP-667
11 DIMENSIONS [mm]
11/11
ISO 4401: 2005
Mounting surface:
4401-03-02-0-05
Fastening bolts:
4 socket head screws M5x50 class 12.9
Tightening torque = 8 Nm
Seals: 4 OR 108
Ports P,A,B,T: Ø = 7.5 mm (max).
P = PRESSURE PORT
A, B = USE PORT
T = TANK PORT
For the max pressures on ports, see section
Mass: 1,5 kg Mass: 1,8 kg
Mass: 1,5 kg
Mass: 1,8 kg
DHI-06
DHU-06
DHI-07
DHU-07
14 MOUNTING SUBPLATES
Model Ports location
GAS Ports
A-B-P-T
Ø Counterbore
[mm]
A-B-P-T
Mass
[kg]
BA-202
BA-204
BA-302
Ports A, B, P, T underneath;
Ports P, T underneath; ports A, B on lateral side
Ports A, B, P, T underneath
3/8"
3/8"
1/2"
25,5
30
1,2
1,8
1,8
The subplates are supplied with 4 fastening bolts M5x50. Also available are multi-station subplates and modular subplates. For further details see table K280.
Overall dimensions refer to valves with connectors type SP-666
13
ELECTRIC CONNECTORS ACCORDING TO DIN 43650
The connectors must be ordered separately
12 OPTION /WP
SP-666, SP-667 (for AC or DC supply) SP-669 (for AC supply)
SP-666, SP-667
1 = Positive
2 = Negative
= Coil ground
SP-666 SP-667 110/50 AC
All 24 AC or DC 110/60 AC
voltages 110 AC or DC 230/50 AC
220 AC or DC 230/60 AC
SP-669
1,2 = Supply voltage V
AC
3 = Coil ground
CONNECTOR WIRING
SUPPLY VOLTAGES
Note: for electronic connectors type E-SD, see tab. K500
DHI
DHU