www.atos.com
Modular fast/slow valves type DHQ and DKQ
compensated flow control and by-pass solenoid valve, ISO 4401 sizes 06 and 10
Table D170-6/E
DHQ and DKQ are modular units compo-
sed by one by-pass solenoid valve and
one 2-way pressure compensated flow
control valve type QV-06 (tab. C210).
The flow control valve is provided with a
built-in check valve to allow the free
flow in the opposite direction.
The flow adjustment is obtained by tur-
ning the graduated micrometer knob .
Clockwise rotation decreases the throt-
tling (passage reduced).
Optional versions with locking key on
the adjustment knob are available on
request.
DHQ = ISO 4401 size 06 interface; con-
trolled flow up to 1,5-6-11-16-24
l/min (depending on models);
free flow up to 36 l/min.
DKQ = ISO 4401 size 10 interface; con-
trolled flow up to 1,5-6-11-16-24
l/min (depending on models);
free flow up to 120 l/min.
Pressure up to 250 bar.
Valves designed to operate in hydraulic
systems with hydraulic mineral oil or
synthetic fluid having similar lubricating
characteristics.
DHQ-0
Modular flow control unit,
pressure compensated,
size:
DHQ-0 = 06
DKQ-0 = 10
1
D170
C = flow controlled when solenoid is de-energized
O = flow controlled when solenoid is energized
Configuration, see section
쪨
control of flow discharged from the actuator
13 = on port A
14 = on port B
16 = on port T
control of flow entering the actuator:
11 = on port P
23 = on port A
24 = on port B
13 / I
MODEL CODE
DHQ-014
DKQ-011 (DC version)
6
Maximum adjustable controlled flow:
1 = 1,5 l/min; 6 = 6 l/min; 11 = 11 l/min; 16 = 16 l/min; 24 = 24 l/min
/K
C
Options:
/K = with lock key for the setting knob
/V = without by-pass check valve
/L1, L2, L3 = device for switching time control (only for DHQ, see tab. E010)
/
Type of solenoid:
for DHQ:
I = solenoid OI for AC and DC supply
for DKQ
E = solenoid AE for AC and DC supply
ER = solenoid AER for AC and DC supply, certified CURUS
X
X = without connector - See section
쪪
24DC
-**
Series number
/*
Max regulated flow [l/min] 1,5 6 11 16 24
Min regulated flow [cm
3
/min] 50 50 50 50 50
Regulating Δp [bar] 3 3 5 6,5 8
Max flow through check valve [l/min] 24
Max free flow 36 l/min for DHQ; 120 l/min for DKQ
Max flow on port A [l/min] 24
Max pressure [bar] 250
2 HYDRAULIC CHARACTERISTICS
D*Q-014/*, D*Q-024/* are similar to corresponding D*Q-013/*, D*Q-023/* but control the flow through port B of solenoid valve
Valve model DHQ-0**/*/1 DHQ-0**/*/6 DHQ-0**/*/11 DHQ-0**/*/16 DHQ-0**/*/24
DKQ-0**/*/1 DKQ-0**/*/6 DKQ-0**/*/11 DKQ-0**/*/16 DKQ-0**/*/24
D*Q-13/C D*Q-13/O
D*Q-23/OD*Q-23/C
D*Q-11/O
D*Q-11/C
D*Q-16/O
D*Q-16/C
PT
PT
PT
PT
PT
PT
PT
PT
Seals material:
omit for NBR (mineral
oil & water glycol)
PE = FPM