4
DIAGRAMS OF HQ-0 based on mineral oil ISO VG 46 at 50°C
1 = Regulation diagram
at Dp 10 bar
(
1.1 = option /U)
2
= Regulation diagram
a
t Dp 30 bar
(2.1 = option /U)
3 = Regulation diagram
a
t Dp 50 bar
(3.1 = option /U)
4
= Q/Dp diagram for
f
ree flow through the
non-return valve
Flow [l/min]
S
etting [knob turns]
Flow [l/min]
Differential pressure [bar]
5
D
IAGRAMS OF KQ-0 based on mineral oil ISO VG 46 at 50°C
1 = Regulation diagram at Dp 10 bar
2 = Regulation diagram at Dp 30 bar
3 = Regulation diagram at Dp 50 bar
4 = Q/Dp diagram for free flow through the
non-return valve
Flow [l/min]
Setting [knob turns]
Flow [l/min]
Differential pressure [bar]
Flow [l/min]
Differential pressure [bar]
Flow [l/min]
Differential pressure [bar]
6
DIAGRAMS OF JPQ-2 based on mineral oil ISO VG 46 at 50°C
1 = Regulation diagram at Dp 10 bar
2 = Regulation diagram at Dp 30 bar
3 = Regulation diagram at Dp 50 bar
4 = Q/Dp diagram for free flow through the
non-return valve
Flow [l/min]
Setting [knob turns]
7 DIAGRAMS OF JPQ-3 based on mineral oil ISO VG 46 at 50°C
1 = Regulation diagram at Dp 10 bar
2 = Regulation diagram at Dp 30 bar
3 = Regulation diagram at Dp 50 bar
4 = Q/Dp diagram for free flow through the
non-return valve
Flow [l/min]
Setting [knob turns]
1
2
3
Flow [l/min]
S
etting [knob turns]
1
.1
2.1
3.1
4
1
2
3
4
4
4
123
123
Mineral oils
Hydraulic fluid
N
BR, FKM, HNBR
F
KM
NBR, HNBR
D
IN 51524
ISO 12922
H
L, HLP, HLPD, HVLP, HVLPD
H
FDU, HFDR
HFC
S
uitable seals type
Classification Ref. Standard
Flame resistant without water
Flame resistant with water
3
M
AIN CHARACTERISTICS, SEALS and HYDRAULIC FLUID -
f
or other fluids not included in below table, consult our technical office
NBR seals (standard) = -20°C ÷ +60°C, with HFC hydraulic fluids = -20°C ÷ +50°C
Seals, recommended fluid temperature FKM seals (/PE option)= -20°C ÷ +80°C
HNBR seals (/BT option)= -40°C ÷ +60°C, with HFC hydraulic fluids = -40°C ÷ +50°C
Recommended viscosity 15÷100 mm
2
/
s - max allowed range 2.8 ÷ 500 mm
2
/
s
Fluid contamination class ISO 4406 class 21/19/16 NAS 1638 class 10, in line filters of 25 mm (b25 _>75 recommended)
Assembly position / location Any position
Subplate surface finishing Roughness index Ra 0,4 - flatness ratio 0,01/100 (ISO 1101)
MTTFd values according to EN ISO 13849 150 years, for further details see technical table P007
Standard execution = -30°C ÷ +70°C
Ambient temperature /PE option = -20°C ÷ +70°C
/BT option = -40°C ÷ +70°C