Assembly position Any position
Subplate surface finishing Roughness index Ra 0,4 - flatness ratio 0,01/100 (ISO 1101)
Ambient temperature -20°C to + 70°
Fluid Hydraulic oil as per DIN 51524...535, for other fluids see section
쪧
Recommended viscosity 15 ÷ 100 mm
2
/s at 40°C (ISO VG 15 ÷ 100)
Fluid contamination class ISO 4401 class 21/19/16 NAS 1638 class 10 (filters at 25 μm value with β25 ≥ 75 recommended)
Fluid temperature -20°C +60°C (standard seals and water glycol) -20°C +80°C (/PE seals)
3 MAIN CHARACTERISTICS OF MODULAR SEQUENCE VALVES TYPE HS, KS
4
REGULATED PRESSURE VERSUS FLOW DIAGRAMS based on mineral oil ISO VG 46 at 50°C
1 =HS
2 =KS
Regulated pressure at port P [bar]
Flow [l/min]
Flow [l/min]
Regulated pressure at port P [bar]
5 INSTALLATION DIMENSIONS [mm]
11/12
ISO 4401: 2005
Mounting surface: 4401-03-02-0-05
Diameter of ports A, B, P, T: Ø = 7,5 mm
Seals: 4 OR 108
Fastening bolts: n°4 socket head screws M5. The lenght depends on number and type of modular elements associated.
ISO 4401: 2005
Mounting surface: 4401-05-04-0-05
Diameter of ports A, B, P, T: Ø = 11,2 mm
Seals: 5 OR 2050
Fastening bolts: n°4 socket head screws M6. The lenght depends on number and type of modular elements associated.
KS-011
Mass: 3 Kg
Mass: 2 Kg
HS-011
Adjustment device for option/V
Adjustment device for option/V
View from X
View from X
1
2
= Pressure gauge port = G 1/
4
”
= Pressure gauge port = G 1/
4
”
Adjustment device for option
/VF and /VS
A
B
TA
TB
P