QV-06/1 QV-06/6 QV-06/11 QV-06/16 QV-06/24
1,5 6 11 16 24
50
24
3 3 5 6,5 8
24
250
www.atos.com
Flow control valves type QV-06
pressure compensated, two way, ISO 4401 size 06
T
able
C210-7/E
Q
V are flow control valves with pressure
c
ompensator 햲: the controlled flow rate is
i
ndependent of pressure variations.
T
hey are usually supplied with a built-in
check valve 햳 to allow the free flow in the
opposite direction.
The flow is regulated by turning a gradua-
t
e micrometer knob 햴. Clockwise rotation
increases the flow regulation.
O
ptional versions with locking key 햵 on
the adjustment knob are available on
r
equest.
ISO 4401 size 06.
Flow up to 1,5; 6; 11; 16; 24 l/min (depen-
ding on models).
P
ressure up to 250 bar.
V
alves designed to operate in hydraulic
s
ystems with hydraulic mineral oil or
synthetic fluid having similar lubricating
c
haracteristics.
Pressure compensated
flow control valve
1
C210
Maximum adjustable flow rate:
1 = 1,5 l/min 11 = 11 l/min 24 = 24 l/min
6 = 6 l/min 16 = 16 l/min
Options:
K = with lock key for the setting knob
V = without by-pass check valve
Size: 06
MODEL CODE
2
HYDRAULIC CHARACTERISTICS
Valve model
Max regulated flow [I/min]
Min regulated flow [cm
3
/min]
Max flow BÆA through check valve
[l/min]
Regulating Dp [bar]
Max flow on port A [l/min]
Max pressure [bar]
Hydraulic symbols
with check valve (standard) without check valve (option /V)
QV-06 QV-06/*/K
Series number
QV
06 6/ //- K **
*
3
MAIN CHARACTERISTICS, SEALS AND FLUIDS - for other fluids not included in below table, consult our technical office
Mineral oils
Hydraulic fluid
NBR, FKM, HNBR
FKM
NBR, HNBR
DIN 51524
ISO 12922
HL, HLP, HLPD, HVLP, HVLPD
HFDU, HFDR
HFC
Suitable seals type
Classification Ref. Standard
Flame resistant without water
Flame resistant with water
NBR seals (standard) = -20°C ÷ +60°C, with HFC hydraulic fluids = -20°C ÷ +50°C
Seals, recommended fluid temperature FKM seals (/PE option) = -20°C ÷ +80°C
HNBR seals (/BT option) = -40°C ÷ +60°C, with HFC hydraulic fluids = -40°C ÷ +50°C
Recommended viscosity 15÷100 mm
2
/s - max allowed range 2,8 ÷ 500 mm
2
/s
Assembly position Any position
Fluid contamination class ISO 4406 class 21/19/16 NAS 1638 class 10, in line filters of 25 mm (b25 _>75 recommended)
Ambient temperature Standard = -30°C ÷ +70°C /PE option = -20°C ÷ +70°C /BT option = -40°C ÷ +70°C
Seals material, see section :
- =
NBR
PE = FKM